{"id":2346,"date":"2025-06-19T19:35:01","date_gmt":"2025-06-19T11:35:01","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/needle-flame-test\/"},"modified":"2025-07-01T17:29:24","modified_gmt":"2025-07-01T09:29:24","slug":"needle-flame-test","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/needle-flame-test\/","title":{"rendered":"IEC60695-2-2\u91dd\u5f0f\u706b\u708e\u8a66\u9a13\u5668"},"content":{"rendered":"<p>The ZY-3 Needle Flamp Test apparatus is mainly used for testing lighting equipment, low-voltage electrical appliances, household appliances, power tools, electronic instruments, electronic meters, etc. Additionally, this instrument is also suitable for testing insulation materials, engineering plastics, and solid flammable materials. The needle flame test apparatus consists of a needle flame burner, a working chamber, and a temperature measuring device.<\/p>\n<p>The needle flame test apparatus utilizes a needle-shaped burner with a specified size (\u03a60.9mm) and is fueled by a specific gas (butane or propane). The burner is oriented at a angle of 45\u00b0 and ignited for a predetermined time onto the test specimen, evaluating the ignition hazard of small flames caused by internal fault conditions of the equipment based on whether the test specimen and the ignition pad ignite, the duration of combustion, and the length of the flame.<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC695-2-2-1994-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60695-2-2:2021<\/a> \u201cFire hazard testing \u2013 Part 2: Test methods \u2013 Section 2: Needle-flame test\u201d<br \/>\nIEC 60695-11-5:2016 \u201cFire hazard testing \u2013 Part 11-5: Test flames \u2013 Needle-flame test method \u2013 Apparatus, confirmatory test arrangement and guidance\u201d<br \/>\nIEC 62368-1:2023 \u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d<\/p>\n<p><strong>Specification:<br \/>\n<\/strong>\u2022 Angle of burner: 45\u00b0 (when in test) \/ 0\u00b0 (when adjust the flame\u2019s height)<br \/>\n\u2022 Needle flame burning time: 0~999.9s\u00b10.1s (adjustable, 30s in general)<br \/>\n\u2022 After-flame time: 0~999.9s\u00b10.1s, auto record and pause manually<br \/>\n\u2022 Height of flame: 12mm\u00b11mm<br \/>\n\u2022 Gas: 95% butane (Note: Digital flow meter is optional with extra cost)<br \/>\n\u2022\u00a0Test range of temperature: 0~1000\u2103<br \/>\n\u2022 The temperature rises from 100\u2103\u00b12\u2103 to 700\u2103\u00b13\u2103 within 23.5 seconds\u00b11s<br \/>\n\u2022 Thermocouple: \u03a60.5mm K type<br \/>\n\u2022 Applied with touch screen and remote control<br \/>\n\u2022 Number of burns for a single test: single or multiple burns can be set<\/p>\n<p>LISUN ZY-3 needle flame tester can run multiple times flame test in a single test automatically according to the Annex S S.1 of the IEC62368-1 standard:<br \/>\n<img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-13478 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC-62368-1.jpg\" sizes=\"(max-width: 853px) 100vw, 853px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC-62368-1.jpg 853w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC-62368-1-400x324.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC-62368-1-768x621.jpg 768w\" alt=\"\" width=\"853\" height=\"690\" title=\"\"><\/p>\n<p>To save the delivery cost for the oversea market, LISUN designed a compact version needle flame test equipment weighing less than 50kg. (Customer need to prepare additional ventilation system for ZY-3S)<\/p>\n<div id=\"attachment_4380\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img decoding=\"async\" class=\"wp-image-4380 size-medium\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ZY-3S_AL-e1594804092777-400x335.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ZY-3S_AL-e1594804092777-400x335.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ZY-3S_AL-e1594804092777-768x643.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ZY-3S_AL-e1594804092777.jpg 1200w\" alt=\"\" width=\"400\" height=\"335\" aria-describedby=\"caption-attachment-4380\" title=\"\"><\/p>\n<p id=\"caption-attachment-4380\" class=\"wp-caption-text\">ZY-3S Needle Flame Test (Compact Version)<\/p>\n<\/div>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/zy-3-needle-flame-tester-is-designed-according-to-iec-60695-2-2.html\" target=\"_blank\" rel=\"noopener\">What is a needle flame test?<\/a><\/strong><br \/>\nThe full name of IEC 60695-2-2\u00a0is Fire hazard testing Part 2: Test methods \u2013 Section 2\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/electrical-safety-tester\/needle-flame-test.html\" target=\"_blank\" rel=\"noopener\"><strong>Needle-flame test<\/strong><\/a>. It was prepared by IEC technical committee 89: Fire hazard testing. The following is the related introduction of IEC 60695-2-2 Scope.<\/p>\n<p>This section of IEC 60695-2-2 specifies a needle-flame test to simulate effect of small flames which may result from fault conditions within equipment, in order to assess by a simulation technique the fire hazard.It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating material or other combustible materials.<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/what-is-flame-retardant-test-methods.html\" target=\"_blank\" rel=\"noopener\">What is flame retardant test methods?<\/a><\/strong><br \/>\nIn the case of horizontal\u00a0<strong>needle flame test<\/strong> HB classification, the sample size is required to be 125mm in length, 13mm in width, and no more than 13mm in thickness. The sample is placed horizontally, the sample clamp is clamped to one end of the sample, and the ignition device is at a 45 degree angle to keep the flame position unchanged. Apply 30\u00b11S to the other end of the sample holder, and place a metal mesh and a freely movable fixed frame horizontally under the sample holder, so that when the sample burns, the free end and the metal mesh are kept 10mm. [<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/what-is-flame-retardant-test-methods.html\" target=\"_blank\" rel=\"noopener\">\u2026more\u2026<\/a>]<\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-zy-3-needle-flame-test-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN ZY-3 Needle Flame Test \u2013 After-sales Frequently Asked Questions (FAQ)<\/a><\/span><br \/>\n<\/strong>LISUN ZY-3 Needle Flame Test were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The ZY-3 Needle Flamp Test apparatus is mainly used for testing lighting equipment, low-voltage electrical appliances, household appliances, power tools, electronic instruments, electronic meters, etc. Additionally, this instrument is also suitable for testing insulation materials, engineering plastics, and solid flammable materials. The needle flame test apparatus consists of a needle flame burner, a working chamber, and a temperature measuring device. The needle flame test apparatus utilizes a needle-shaped burner with a specified size (\u03a60.9mm) and is fueled by a specific gas (butane or propane). The burner is oriented at a angle of 45\u00b0 and ignited for a predetermined time onto the test specimen, evaluating the ignition hazard of small flames [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3781,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[46],"class_list":["post-2346","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-zy-3"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2346"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2346\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/3781"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2346"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2346"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}