{"id":2380,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/scientific-grade-ccd-spectroradiometer\/"},"modified":"2025-06-27T14:05:44","modified_gmt":"2025-06-27T06:05:44","slug":"scientific-grade-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/scientific-grade-ccd-spectroradiometer\/","title":{"rendered":"\u79d1\u5b66\u30b0\u30ec\u30fc\u30c9CCD\u5206\u5149\u653e\u5c04\u8a08"},"content":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.<\/p>\n<p><strong>\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"\u767d\u8272LED\u5149\u6e90\u306e\u6f14\u8272\u6027\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"\u5149\u675f\u306e\u6e2c\u5b9a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"\u5149\u6e90\u306e\u6f14\u8272\u7279\u6027\u306e\u6e2c\u5b9a\u65b9\u6cd5\u304a\u3088\u3073\u6307\u5b9a\u65b9\u6cd5\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \u300c\u56fa\u4f53\u7167\u660e\u88fd\u54c1\u306e\u5149\u5b66\u7684\u304a\u3088\u3073\u96fb\u6c17\u7684\u6e2c\u5b9a\u300d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"\u6e2c\u5149\u30c7\u30fc\u30bf\u3068\u95a2\u9023\u60c5\u5831\u306e\u96fb\u5b50\u8ee2\u9001\u306e\u305f\u3081\u306eIESNA\u6a19\u6e96\u30d5\u30a1\u30a4\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\" (IESNA Standard File Format for Electronic Transfer of Photometric Data and Related Information)<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"LED\u5149\u6e90\u306e\u30eb\u30fc\u30e1\u30f3\u7dad\u6301\u7387\u306e\u6e2c\u5b9a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"\u96fb\u6c17\u30e9\u30f3\u30d7\u7528\u56fa\u4f53\u7167\u660e\u88fd\u54c1\u306e\u8272\u5ea6\u306b\u95a2\u3059\u308b\u898f\u683c\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(EU) 2019\/2015<\/a> \u300c\u59d4\u54e1\u4f1a\u59d4\u4efb\u898f\u5247<\/p>\n<p><strong>\u4ed5\u69d8\uff1a<\/strong><br \/>\n\u2022 CCD detector: Hamamatsu TE-cooled (Temp: -10\u00b0C \u00b10.05\u00b0C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)<br \/>\n- \u30b9\u30da\u30af\u30c8\u30eb\u6ce2\u9577\u7cbe\u5ea6\uff1a\u00b10.2nm\u3001\u5206\u89e3\u80fd\uff1a\u00b10.1nm\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30ad\u30e3\u30cb\u30f3\u30b0\u30b9\u30c6\u30c3\u30d7\uff1a\u00b10.1nm<br \/>\n- \u8272\u5ea6\u5ea7\u6a19\uff08\u0394x\u3001\u0394y\uff09\u306e\u7cbe\u5ea6\uff1a\u00b10.0015\uff08\u6a19\u6e96A\u30e9\u30f3\u30d7\u4f7f\u7528\u6642\uff09<br \/>\n- \u76f8\u95a2\u8272\u6e29\u5ea6 CCT: 1\u3001500K~100\u3001000K \u306e CCT \u306e\u6b63\u78ba\u3055: \u00b10.2%<br \/>\n- \u6f14\u8272\u8a55\u4fa1\u6570\u7bc4\u56f2\uff1a0~100.0 \u306e\u6b63\u78ba\u3055: \u00b1 \uff080.3%rd\u00b10.3\uff09<br \/>\n\u2022 Photometric linear: \u00b10.2%, Stray light: &lt;0.015%(600nm) and &lt;0.03% (435nm)<br \/>\n- \u7a4d\u5206\u6642\u9593: 0.1ms-60s<br \/>\n- \u7a4d\u5206\u7403\u306e\u5185\u5074\u3068\u5916\u5074\u306e\u6e29\u5ea6\u3092\u6e2c\u5b9a\u3067\u304d\u308b\u3002<br \/>\n\u2022 Flux testing method: spectrum, photometric, spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>LISUN\u30e2\u30c7\u30eb<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUVIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CSWIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>\u6ce2\u9577<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<td style=\"width: 20%;\">800-1700nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2(LMS-9500C) \u9ad8\u7cbe\u5ea6\u5206\u5149\u653e\u5c04\u8a08\u306e\u7a4d\u5206\u7403\u30b7\u30b9\u30c6\u30e0 - \u30a2\u30d5\u30bf\u30fc\u30bb\u30fc\u30eb\u30b9\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\u3002<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2(LMS-9500C)\u306e\u9ad8\u7cbe\u5ea6\u306e\u5206\u5149\u653e\u5c04\u8a08\u306e\u7d71\u5408\u306e\u7403\u30b7\u30b9\u30c6\u30e0\u306f10\u5e74\u9593\u4ee5\u4e0a\u5e02\u5834\u306b\u3042\u3063\u305f\u3001LISUN\u30a8\u30f3\u30b8\u30cb\u30a2\u306e\u30b5\u30fc\u30d3\u30b9\u30c1\u30fc\u30e0\u306f\u65e2\u306b\u4e0a\u306e\u30ea\u30f3\u30af\u306e\u30a2\u30d5\u30bf\u30fc\u30bb\u30fc\u30eb\u30b9\u306e\u8cea\u554f\u304a\u3088\u3073\u7b54\u3048\u306e\u307b\u3068\u3093\u3069\u3092\u8981\u7d04\u3057\u305f\u3002\u305d\u308c\u3092carefuly\u8aad\u3093\u3067\u4e0b\u3055\u3044\u3001\u5668\u68b0\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u9593\u8cea\u554f\u304c\u3042\u308c\u3070\u554f\u984c\u306e\u307b\u3068\u3093\u3069\u3092\u72ec\u308a\u3067\u89e3\u6c7a\u3067\u304d\u308b\u3002LISUN\u306f\u3053\u306e\u30da\u30fc\u30b8\u3092\u66f4\u65b0\u3057\u7d9a\u3051\u3001\u3088\u308a\u591a\u304f\u306eFAQ\u306f\u3053\u306e\u30c8\u30d4\u30c3\u30af\u306e\u30ea\u30f3\u30af\u3067\u898b\u3064\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3002<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards. Standard: CIE 177 \u201cColor Rendering of White LED Light Sources\u201d CIE84 \u201cThe measurement of luminous flux\u201d CIE-13.3 \u201cMethod of Measuring and Specifying [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[137],"class_list":["post-2380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9500c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2380"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/4774"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}