{"id":2406,"date":"2025-06-19T19:35:35","date_gmt":"2025-06-19T11:35:35","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ccd-spectroradiometer\/"},"modified":"2025-06-27T14:48:26","modified_gmt":"2025-06-27T06:48:26","slug":"ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/ccd-spectroradiometer\/","title":{"rendered":"CCD\u5206\u5149\u653e\u5c04\u8a08"},"content":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy.<br \/>\n\u2022\u00a0The following wavelength range is with 0.8nm FWHM:<\/p>\n<table border=\"1\" width=\"921\" cellspacing=\"1\" cellpadding=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td>LMS-7000UV<\/td>\n<td>LMS-7000UV-VIS<\/td>\n<td>LMS-7000VIS<\/td>\n<td>LMS-7000VIS-NIR<\/td>\n<td>LMS-7000UV-VIS-NIR<\/td>\n<\/tr>\n<tr>\n<td>200~400nm<\/td>\n<td>200~800nm<\/td>\n<td>350~950nm<\/td>\n<td>350~1050nm<\/td>\n<td>200~1050nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u2022 Integration time: 0.5ms to 1,0000ms<br \/>\n\u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm<br \/>\n\u2022\u00a0SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A\/D is 16bit<br \/>\n\u2022 Communicate with PC by USB2.0. The software has a rich re-develop platform which can run on Win7, Win8, Win10, Win11<br \/>\n\u2022 Optical fiber port is SMA905<\/p>\n<p><strong>\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \u300c\u56fa\u4f53\u7167\u660e\u88fd\u54c1\u306e\u5149\u5b66\u7684\u304a\u3088\u3073\u96fb\u6c17\u7684\u6e2c\u5b9a\u300d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"\u6e2c\u5149\u30c7\u30fc\u30bf\u3068\u95a2\u9023\u60c5\u5831\u306e\u96fb\u5b50\u8ee2\u9001\u306e\u305f\u3081\u306eIESNA\u6a19\u6e96\u30d5\u30a1\u30a4\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\" (IESNA Standard File Format for Electronic Transfer of Photometric Data and Related Information)<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"\u767d\u8272LED\u5149\u6e90\u306e\u6f14\u8272\u6027\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"\u5149\u675f\u306e\u6e2c\u5b9a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"\u5149\u6e90\u306e\u6f14\u8272\u7279\u6027\u306e\u6e2c\u5b9a\u65b9\u6cd5\u304a\u3088\u3073\u6307\u5b9a\u65b9\u6cd5\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"\u96fb\u6c17\u30e9\u30f3\u30d7\u7528\u56fa\u4f53\u7167\u660e\u88fd\u54c1\u306e\u8272\u5ea6\u306b\u95a2\u3059\u308b\u898f\u683c\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(EU) 2019\/2015<\/a> \u300c\u59d4\u54e1\u4f1a\u59d4\u4efb\u898f\u5247<\/p>\n<p><strong>Typical Application:<br \/>\n<\/strong>The LMS-7000 is for LED color &amp; lumen test. It works with <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u7a4d\u5206\u7403<\/a> and standard lamp as a system: <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/ccd-spectroradiometer-integrating-sphere-compact-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System<\/a>. This system can do the following test.<\/p>\n<p><strong>\u6e2c\u5b9a\uff1a<br \/>\n<\/strong>Colorimetric: Chromaticity Coordinate (x, y) and (u, v), Relative Spectral Power Distribution P(\u03bb), Correlated Color Temperature (Tc), Color Rendering Index (Ra, R1 to R15), Color Difference, Dominant Wavelength, Peak Wavelength, Half-bandwidth, Spectral Purity, TM30 (Rf, Rg), CQS<br \/>\nPhotometric: Luminous Flux (Lumen), Luminous Efficiency, Radiant Power, EEI, PAR, PPF<br \/>\nElectrical: Voltage, Current, Power, Power Factor, Harmonic (Optional)<\/p>\n<p><strong>\u4ed5\u69d8\uff1a<br \/>\n<\/strong>\u2022\u00a0Spectral Resolution: \u00b10.2nm<br \/>\n\u2022\u00a0Reproducibility: \u00b10.5nm<br \/>\n\u2022\u00a0Accuracy of Chromaticity Coordinate (\u0394x, \u0394y): \u00b10.003<br \/>\n\u2022 Correlated Color Temperature CCT: 1, 500K ~ 25, 000K, CCT Accuracy:\u00b10.5%<br \/>\n\u2022 High spectral resolution, high sensitivity and excellent reliability<\/p>\n<p><strong>Other Applications:<br \/>\n<\/strong>The LMS-7000 can also work with other accessories. It can be used in the following field and area. Please contact LISUN sales dept for the detail solution and spectroradiometer price.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-1990 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg 700w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer-400x180.jpg 400w\" alt=\"LMS-7000 CCD Spectroradiometer\" width=\"700\" height=\"315\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-3-ccd-spectroradiometer-integrating-sphere-compact-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-3 (LMS-7000) CCD\u306e\u5206\u5149\u653e\u5c04\u8a08\u306e\u7d71\u5408\u306e\u7403\u306e\u30b3\u30f3\u30d1\u30af\u30c8\u30b7\u30b9\u30c6\u30e0 - \u30a2\u30d5\u30bf\u30fc\u30bb\u30fc\u30eb\u30b9\u306e\u3088\u304f\u3042\u308b\u8cea\u554f(FAQ)\u00a0<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-3\u30b7\u30b9\u30c6\u30e0\u306f\u5e02\u5834\u306b10\u5e74\u4ee5\u4e0a\u3042\u3063\u305f\u3001LISUN\u306e\u30a8\u30f3\u30b8\u30cb\u30a2\u306e\u30b5\u30fc\u30d3\u30b9\u30c1\u30fc\u30e0\u306f\u65e2\u306b\u4e0a\u306e\u30ea\u30f3\u30af\u306e\u30a2\u30d5\u30bf\u30fc\u30bb\u30fc\u30eb\u30b9\u306e\u8cea\u554f\u304a\u3088\u3073\u7b54\u3048\u306e\u307b\u3068\u3093\u3069\u3092\u8981\u7d04\u3059\u308b\u3002\u6ce8\u610f\u6df1\u304f\u305d\u308c\u3092\u8aad\u3093\u3067\u4e0b\u3055\u3044\u3001\u5668\u68b0\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u9593\u8cea\u554f\u304c\u3042\u3063\u305f\u3089\u307b\u3068\u3093\u3069\u306e\u554f\u984c\u3092\u72ec\u308a\u3067\u89e3\u6c7a\u3067\u304d\u307e\u3059\u3002LISUN\u306f\u3053\u306e\u30da\u30fc\u30b8\u3092\u66f4\u65b0\u3057\u7d9a\u3051\u3001\u3088\u308a\u591a\u304f\u306eFAQ\u306f\u3053\u306e\u30c8\u30d4\u30c3\u30af\u306e\u30ea\u30f3\u30af\u3067\u898b\u3064\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3002<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy. \u2022\u00a0The following wavelength range is with 0.8nm FWHM: LMS-7000UV LMS-7000UV-VIS LMS-7000VIS LMS-7000VIS-NIR LMS-7000UV-VIS-NIR 200~400nm 200~800nm 350~950nm 350~1050nm 200~1050nm \u2022 Integration time: 0.5ms to 1,0000ms \u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm \u2022\u00a0SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A\/D is 16bit \u2022 Communicate with PC by USB2.0. The software has a rich re-develop platform which can run on Win7, Win8, Win10, Win11 \u2022 Optical fiber port is SMA905 Standard: LM-79-19 \u201cOptical and Electrical Measurements of Solid State Lighting Products\u201d IESNA LM-63-2 \u201cIESNA Standard File Format for the Electronic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3423,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[163],"class_list":["post-2406","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-7000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2406","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2406"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2406\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/3423"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2406"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2406"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2406"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}