{"id":2543,"date":"2025-06-19T19:36:45","date_gmt":"2025-06-19T11:36:45","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/battery-tester\/"},"modified":"2025-06-25T17:51:11","modified_gmt":"2025-06-25T09:51:11","slug":"battery-tester","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/battery-tester\/","title":{"rendered":"Battery Tester"},"content":{"rendered":"<p>The LS556X series of high-voltage, high-precision battery internal resistance testers are specially designed to meet battery industry test requirements. And it is developed for the testing of low-resistance and large-scale lithium battery packs and high-speed assembly line sorting. With many years of technical advantages in the field of impedance testing, the LS556X series come with highest test resolution to reach 0.1<span class=\"text__NfVs\" data-text=\"true\">\u03bc<\/span>\u03a9 and voltage resolution up to 10<span class=\"text__NfVs\" data-text=\"true\">\u03bc<\/span>V. The is equipped with standard RS232C and HANDLER interfaces, which can be easily set up an automated test system.<\/p>\n<p><strong>\u4ed5\u69d8<\/strong>:<br \/>\n\u2022 Included 4.3-inch LCD screen display, battery internal resistance R and voltage V are displayed at the same time;<br \/>\n\u2022 Minimum resolution: 0.1u\u03a9, 10uV;<br \/>\n\u2022 High precision, good stability, the fastest test speed up to 100 times\/second;<br \/>\n\u2022 Test lead contact check function;<br \/>\n\u2022 Built-in comparator function, 10-level sorting;<br \/>\n\u2022 Equipped HANDLER sorting interface to achieve automatic online function;<br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Standard RS232 (Option: RS485) communication interface, supports SCPI and Modbus (RTU) communication modes<\/span><\/span><\/span><br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Test conditions are automatically saved, 50 sets of settings files are stored in the instrument and 500 sets of settings files are stored in the USB flash drive<\/span><\/span><\/span><br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Patented invention, test results can be uploaded directly to the computer without installing software<\/span><\/span><\/span><\/p>\n<table style=\"width: 99.9457%; height: 1495px;\" width=\"632\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\"><strong>LISUN\u30e2\u30c7\u30eb<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\"><strong>LS5560<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\"><strong>LS5562<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\"><strong>LS5562A<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Measure Parameters<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">RV\/R\/V (R: AC resistance V: DC voltage)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Test Method<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">AC 4-terminal measurement (1kHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" rowspan=\"2\" width=\"158\">Max Input Voltage<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Rated input voltage 60VDC<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Rated input voltage 60VDC<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">The rated input voltage 300VDC<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Max rated voltage to ground: 60VDC<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Max rated voltage to ground: 60VDC<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">\u00a0Max rated voltage to ground: 300VDC<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" rowspan=\"8\" width=\"158\">Resistance Measure Range<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">5 ranges<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">7 ranges<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">3m\u03a9 (Max display: 3.1000m\u03a9, Resolution: 0.1\u03bc\u03a9)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">3m\u03a9 (Max display: 3.1000m\u03a9, Resolution: 0.1\u03bc\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">30m\u03a9 (Max display: 31.000m\u03a9, Resolution: 1\u03bc\u03a9)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">30m\u03a9 (Max display: 31.000m\u03a9, Resolution: 1\u03bc\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">300m\u03a9 (Max display: 310.00m\u03a9, Resolution: 10\u03bc\u03a9)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">300m\u03a9 (Max display: 310.00m\u03a9, Resolution: 10\u03bc\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">3\u03a9 (Max display: 3.1000\u03a9, Resolution: 0.1m\u03a9)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">3\u03a9 (Max display: 3.1000\u03a9, Resolution: 0.1m\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">30\u03a9 (Max display: 31.000\u03a9, Resolution: 1m\u03a9)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">30\u03a9 (Max display: 31.000\u03a9, Resolution: 1m\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\"><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">300\u03a9 (Max display: 310.00\u03a9, Resolution: 10m\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\"><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"316\">3000\u03a9 (Max display: 3100.0\u03a9, Resolution: 100m\u03a9)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" rowspan=\"2\" width=\"158\">\u6b63\u78ba\u3055<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">30m\u03a9 \uff5e 3000\u03a9 range: \u00b1 0.5%RDG. \u00b1 5dgt. (EX.Fast needs to be added \u00b1 3dgt., Fast\/medium, \u00b1 2dgt.)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">3m\u03a9~30m\u03a9 range: \u00b1 0.5%RDG. \u00b1 10dgt. (EX.Fast need to be added \u00b1 10dgt., Fast when you need to add \u00b1 5dgt.)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Voltage Measure Range<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"158\">DC6V (resolution 10 \u03bcV) DC60V (resolution 100 \u03bcV), two range switching<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">DC6V (resolution 10 \u03bcV) DC60V (resolution 100 \u03bcV), DC300V (resolution 1mV),three range switching<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Voltage Measurement Accuracy<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">EX. FAST:\u00b10.01%.\u00b13dgt. Add\u00b13dgt, FAST: Add\u00b1 2dgt., MED :ADD\u00b1 2dgt.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Sampling Time<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">EX.FAST: 4ms, FAST: 12ms, MEDIUM: 42ms, SLOW: 157ms (The above is the fastest time for measuring a single parameter, the power frequency is 50Hz, the specific time depends on the test item and power frequency)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Full Measure Time<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">Response time + sampling time (The impedance\/voltage common response time is about 1ms, for reference only, the specific time depends on the test process and the object being tested)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Comparators<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">Independent judgment: HI\/IN\/LO (voltage and impedance are judged independently), comprehensive judgment (PASS\/FAIL. AND operation of impedance judgment result and voltage judgment result). LED display, buzzer alarm, external I\/O output<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">External interface<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">Handler I\/O,RS-232C,USB<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Power requirements<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">AC:85-242V\u00a0\uff0c47\uff5e63Hz\uff0c15VA<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">Size((W*H*D)<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">215mm*87mm*335mm (net size), 235mm*105mm*360mm (after adding cites)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">\u91cd\u91cf<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">3.6KGS<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"158\">External Interface<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"474\">Handler I\/O, RS-232C, USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Application\uff1a<\/strong><br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Measurement and life evaluation of alkaline and lead batteries<\/span><\/span><\/span><br \/>\n\u2022 UPS detection<br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz\"><span class=\"ryNqvb\">Battery Factory Inspection<\/span><\/span><\/span><br \/>\n\u2022 High-precision internal resistance and voltage detection of lithium battery<br \/>\n\u2022 High-speed mass production random inspection of buttons<br \/>\n\u2022 Measurement of fuel cell group<br \/>\n\u2022 Test of high-voltage battery packs such as electric vehicle lithium batteries<br \/>\n\u2022 Multi-section series high-voltage lithium battery internal resistance and voltage measurement<br \/>\n\u2022 Measurement of hydrogen fuel cell resistance and voltage<br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Equipped with automatic sorting machine for automatic battery internal resistance + voltage testing<\/span><\/span><\/span><br \/>\n\u2022 <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Battery degradation status and life assessment<\/span><\/span><\/span><br \/>\n\u2022 ESR test of super capacitance (low internal resistance capacitor)<\/p>","protected":false},"excerpt":{"rendered":"<p>The LS556X series of high-voltage, high-precision battery internal resistance testers are specially designed to meet battery industry test requirements. And it is developed for the testing of low-resistance and large-scale lithium battery packs and high-speed assembly line sorting. With many years of technical advantages in the field of impedance testing, the LS556X series come with highest test resolution to reach 0.1\u03bc\u03a9 and voltage resolution up to 10\u03bcV. The is equipped with standard RS232C and HANDLER interfaces, which can be easily set up an automated test system. Specification: \u2022 Included 4.3-inch LCD screen display, battery internal resistance R and voltage V are displayed at the same time; \u2022 Minimum resolution: 0.1u\u03a9, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3456,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[296],"class_list":["post-2543","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls5562"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2543","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2543"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2543\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/3456"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2543"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2543"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2543"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}