{"id":2969,"date":"2025-06-19T19:42:51","date_gmt":"2025-06-19T11:42:51","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-61386-1-2017-clause-10-2-and-figure-1-conduits-compression-test-apparatus\/"},"modified":"2025-06-24T17:16:11","modified_gmt":"2025-06-24T09:16:11","slug":"iec-61386-1-2017-%e7%ac%ac-10-%e6%9d%a1-2-%e3%81%8a%e3%82%88%e3%81%b3%e5%9b%b3-1-%e3%82%b3%e3%83%b3%e3%82%b8%e3%83%83%e3%83%88%e5%9c%a7%e7%b8%ae%e8%a9%a6%e9%a8%93%e8%a3%85%e7%bd%ae","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/iec-61386-1-2017-%e7%ac%ac-10-%e6%9d%a1-2-%e3%81%8a%e3%82%88%e3%81%b3%e5%9b%b3-1-%e3%82%b3%e3%83%b3%e3%82%b8%e3%83%83%e3%83%88%e5%9c%a7%e7%b8%ae%e8%a9%a6%e9%a8%93%e8%a3%85%e7%bd%ae\/","title":{"rendered":"IEC 61386-1: 2017 \u7b2c10.2\u9805\u304a\u3088\u3073\u56f31 \u96fb\u7dda\u7ba1\u5727\u7e2e\u8a66\u9a13\u88c5\u7f6e"},"content":{"rendered":"<p>\u30b3\u30f3\u30b8\u30c3\u30c8\u5727\u7e2e\u8a66\u9a13\u6a5f\u306f\u3001\u5404\u7a2e\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u30d1\u30a4\u30d7\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u30b3\u30eb\u30b2\u30fc\u30c8\u30d1\u30a4\u30d7\u306a\u3069\u306e\u5727\u529b\u8a66\u9a13\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u8a66\u6599\u306e\u4e0a\u306b\u7acb\u65b9\u4f53\u306e\u9244\u306e\u30d6\u30ed\u30c3\u30af\u3092\u7f6e\u304d\u3001\u30ec\u30d0\u30fc\u3068\u304a\u3082\u308a\u3067\u3086\u3063\u304f\u308a\u3068\u529b\u3092\u52a0\u3048\u307e\u3059\u3002\u5927\u578b\u8868\u9762\u7c97\u3055\u8a08\u306f\u3001\u5e73\u5766\u5316\u70b9\u306b\u304a\u3051\u308b\u30b5\u30f3\u30d7\u30eb\u306e\u5916\u5f84\u5909\u5316\u3092\u6e2c\u5b9a\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6a5f\u68b0\u7684\u7279\u6027\u3092\u30c1\u30a7\u30c3\u30af\u3057\u307e\u3059\u3002IEC 61386-1: 2017 Clause 10.2 and Figure 1 (GB\/T 20041.1-2015 Clause 10.2 and Figure 1)\u3001GB\/T 14823.2\u3001JG 3050\u3001ZBG 33008\u306b\u6e96\u62e0\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><strong>\u4ed5\u69d8<\/strong><br \/>\n- \u6700\u5927\u5727\u529b\uff1a5000N<br \/>\n- \u5727\u529b\u7cbe\u5ea6\uff1a\u00b11%<br \/>\n- \u5727\u529b\u30d8\u30c3\u30c9\u4ed5\u69d8\uff1a50*50mm<br \/>\n- \u30d1\u30a4\u30d7\u5f84\u5909\u66f4\u6e2c\u5b9a\u7bc4\u56f20-12mm\u3001\u6e2c\u5b9a\u7cbe\u5ea60.01mm<br \/>\n- \u6301\u3061\u4e0a\u304c\u308b\u7248\u306e\u30b5\u30a4\u30ba: 300*150mm<br \/>\n- \u30ea\u30d5\u30c8\u7bc4\u56f2\uff1a200mm<br \/>\n- \u5168\u4f53\u306e\u5bf8\u6cd5\uff1a310*210*700mm<br \/>\n- \u91cd\u91cf\uff1a55kg<\/p>\n<p><div id=\"attachment_16837\" style=\"width: 587px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-16837\" decoding=\"async\" class=\"wp-image-16837 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-1-2017-Clause-10.2.png\" alt=\"\" width=\"577\" height=\"929\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-1-2017-Clause-10.2.png 577w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-1-2017-Clause-10.2-248x400.png 248w\" sizes=\"auto, (max-width: 577px) 100vw, 577px\" title=\"\"><\/p>\n<p id=\"caption-attachment-16837\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 61386-1: 2017 \u7b2c10.2\u9805<\/span><\/p>\n<\/div>\n<div id=\"attachment_16838\" style=\"width: 632px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-16838\" decoding=\"async\" class=\"wp-image-16838 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-1-2017-Figure-1.png\" alt=\"\" width=\"622\" height=\"360\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-1-2017-Figure-1.png 622w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/04\/IEC-61386-1-2017-Figure-1-400x232.png 400w\" sizes=\"auto, (max-width: 622px) 100vw, 622px\" title=\"\"><\/p>\n<p id=\"caption-attachment-16838\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 61386-1: 2017 \u56f3 1<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Conduits Compression Test Apparatus is suitable for pressure testing of various plastic pipes, plastic corrugated pipes, etc. A cubic steel block is placed on the sample, and a slowly increasing force is applied by the lever and the weight. The large-scale surface meter measures the change in the outer diameter of the sample at the flattening point, and checks the mechanical properties of the sample. It complies with IEC 61386-1: 2017 Clause 10.2 and Figure 1 (GB\/T 20041.1-2015 Clause 10.2 and Figure 1), GB\/T 14823.2, JG 3050 and ZBG 33008. Specifications: \u2022\u00a0 Maximum pressure: 5000N \u2022\u00a0 Pressure accuracy: \u00b11% \u2022\u00a0 Pressure head specification: 50*50mm \u2022\u00a0 Pipe diameter change measurement range: [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3491,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[663],"class_list":["post-2969","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-b50"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2969","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2969"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2969\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/3491"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2969"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2969"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2969"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}