The LS8815 impulse winding tester is specially designed for the testing needs of winding components. It uses high-voltage charging of small capacitors (low test energy) to form RLC parallel resonance with the coil to be tested. Through the oscillation attenuation waveform, up to 100Msps (customizable 200Msps) and precise sampling processing and analysis technology, it can test the poor self-insulation of the coil (turn-to-turn short circuit, layer-to-layer short circuit, reduced insulation performance, etc.), so that component manufacturers and users can more effectively control product quality.
LS8815 series are with fast measurement speed, good repeatability of the test waveform. It can be widely used in motor, power frequency transformer, relay, switching power transformer, degaussing coil and other wire wound components. LS8815 series can be used in automated test systems to greatly improve test efficiency.
๋ค์์ ์ ํ ๋ชจ๋ธ๊ณผ ์ฐจ์ด์ ์ด๋ฉฐ, ํ์์ ๋ฐ๋ผ ๊ตฌ๋งคํ์๊ธฐ ๋ฐ๋๋๋ค:
โข LS8815-3KV pulse voltage output: 100-3000V
โข LS8815-5KV pulse voltage output: 100-5000V
โข LS8815-10KV pulse voltage output: 100-10000V
โข LS8815S-8 8-channel test, pulse voltage output: 100-5000V
LISUN ๋ชจ๋ธ | LS8815-5KV | LS8815-3KV |
Output pulse voltage |
100V๏ฝ5000V 10V step 5%ยฑ10V |
100V๏ฝ3000V 10V step 5%ยฑ10V |
Inductance test range | >10ฮผH | |
Pulse maximum energy | 0.25J | |
Waveform display content | 800ร480ย Lattice graphic liquid crystal 650ร250 Lattice Enlarge display, set parameters, standard and test waveforms, compare results, file information, etc |
|
Waveform sampling | Sampling rate: 100MSa/s๏ฝ100kSa/s; Total 10 file resolution: 8bits Sampling point: 6500bytes |
|
Standard wave sampling | Continuous cycle, single cycle, single sample (up to 32 sample averages) | |
Input impedance | 10Mฮฉ | |
์๋ ์ธก์ | Max. 15 times/second | |
Test pulse | 1~32 times programmable | |
Degaussing pulse | 0~16 times programmable | |
Display waveform
measurement |
Voltage, time, frequency | |
ํธ๋ฆฌ๊ฑฐ ๋ชจ๋ | Internal / Manual (Foot control) / External / Bus | |
Comparison mode | AreaSize Comparison, Di๏ฌZone Comparison, Corona Comparison, PhaseDi๏ฌย Comparison | |
Area repetition accuracy | ยฑ1% | |
Area difference repetition accuracy | ยฑ1% | |
Discriminant output | PASS, FAIL, LED display, Buzzer alarm | |
Alarm volume selection | Long treble, long bass, single short, double short, off | |
Memorizer | Internal: 200 groups of files External USB flash drive: 500 groups of files | |
Port | HANDLER (START, STOP, PASS, NG, BUSY, EOC.), RS232C, IEEE488(Optional) , USB DEVICE, USBHOST |