{"id":2354,"date":"2025-06-19T19:35:01","date_gmt":"2025-06-19T11:35:01","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/integrated-sphere-spectrophotometer-test-system\/"},"modified":"2025-06-27T10:47:51","modified_gmt":"2025-06-27T02:47:51","slug":"integrated-sphere-spectrophotometer-test-system","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ko\/%ec%a0%9c%ed%92%88\/integrated-sphere-spectrophotometer-test-system\/","title":{"rendered":"Integrated Sphere Spectrophotometer Test System"},"content":{"rendered":"<p>This <strong>Integrated Sphere Spectrophotometer<\/strong> Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-79<\/a> for the measurement of photometry and colorimetry.<\/p>\n<p><strong>\ud45c\uc900:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"\ubc31\uc0c9 LED \uad11\uc6d0\uc758 \uceec\ub7ec \ub80c\ub354\ub9c1\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"\uad11\uc18d \uce21\uc815\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"\uad11\uc6d0\uc758 \uceec\ub7ec \ub80c\ub354\ub9c1 \uc18d\uc131\uc744 \uce21\uc815\ud558\uace0 \uc9c0\uc815\ud558\ub294 \ubc29\ubc95\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"\uc194\ub9ac\ub4dc \uc2a4\ud14c\uc774\ud2b8 \uc870\uba85 \uc81c\ud488\uc758 \uad11\ud559 \ubc0f \uc804\uae30 \uce21\uc815\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"\uad11\ub3c4 \ub370\uc774\ud130 \ubc0f \uad00\ub828 \uc815\ubcf4\uc758 \uc804\uc790\uc801 \uc804\uc1a1\uc744 \uc704\ud55c IESNA \ud45c\uc900 \ud30c\uc77c \ud615\uc2dd\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \u201cMeasuring Lumen Maintenance of LED Light Sources\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"\uc804\uae30 \ub7a8\ud504\uc6a9 \uace0\uccb4 \uc870\uba85 \uc81c\ud488\uc758 \uc0c9\ub3c4 \uc0ac\uc591\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(EU) 2019\/2015<\/a> \"\uc704\uc6d0\ud68c \uc704\uc784 \uaddc\uc815\"<\/p>\n<p><strong>System Configuration:<br \/>\n<\/strong><a href=\"https:\/\/www.lisungroup.com\/products\/spectroradiometer\/quick-scan-spectrophotometer-colorimeter.html\" target=\"_blank\" rel=\"noopener\">\ud035 \uc2a4\uce94 \ubd84\uad11\uad11\ub3c4\uacc4 \uc0c9\ub3c4\uacc4<\/a>\u00a0(LMS-5000),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/optical-fiber.html\" target=\"_blank\" rel=\"noopener\">\uad11\uc12c\uc720<\/a>\u00a0(CFO-1.2M),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-ac-dc-model.html\" target=\"_blank\" rel=\"noopener noreferrer\">\ub514\uc9c0\ud138 \ud30c\uc6cc \ubbf8\ud130<\/a>\u00a0(LS2012 or LS2010),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-cc-and-cv-dc-power-supply.html\" target=\"_blank\" rel=\"noopener noreferrer\">DC Power Supply<\/a>\u00a0(DC Series),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-source.html\" target=\"_blank\" rel=\"noopener noreferrer\">AC \uc804\uc6d0<\/a>\u00a0(LSP-500VAR or LSP-1KVAR ),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">\uc801\ubd84\uad6c<\/a>\u00a0(IS-1.5MA or IS-2.0MA), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/standard-light-source.html\" target=\"_blank\" rel=\"noopener\">Standard Lamp Source<\/a> (SLS-50W), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/19inch-standard-instrument-cabinet.html\" target=\"_blank\" rel=\"noopener\">CASE-19IN 19Inch Cabinet<\/a><\/p>\n<p><strong>Integrated Sphere Spectrophotometer Test System measures photometry, colorimetry and electricity:\u00a0<\/strong><br \/>\n\u2022\u00a0Color parameters: chromaticity coordinate, CCT (correlated color temperature), CRI (color rending index), color difference, peak wavelength;<br \/>\n\u2022\u00a0Photometry parameters: luminous flux, luminous power, luminous flux efficiency;<br \/>\n\u2022\u00a0Electrical parameters: voltage, current, power, power factor<\/p>\n<p><strong>\uc0ac\uc591:\u00a0<\/strong><br \/>\n\u2022\u00a0High accuracy and high speed test less than 10 seconds<br \/>\n\u2022\u00a0Spectral Range Wavelength: 380nm ~ 800nm (Option: 200nm ~ 800nm UV-VIS)<br \/>\n\u2022\u00a0Spectral Wavelength Accuracy: \u00b10.2nm, Wavelength Reproducibility: \u00b10.1nm<br \/>\n\u2022\u00a0Sample Scanning Steps: 5nm (Optional: 1nm)<br \/>\n\u2022\u00a0Accuracy of Chromaticity Coordinate (\u0394x, \u0394y): \u00b10.0003 (based on standard illuminate A)<br \/>\n\u2022\u00a0Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: \u00b10.3%<br \/>\n\u2022\u00a0Color Rendering Index Range: 0~100.0, Accuracy: \u00b10.3% (based on standard illuminate A)<br \/>\n\u2022\u00a0Photometry linearity: \u00b10.3%, Photometer detector: Class A<br \/>\n\u2022\u00a0Luminous Flux: 0.01lm~1,999,900lm (Equipped with right size of integrating sphere)<br \/>\n\u2022\u00a0Environment temperature measure range: -10\u00b0C~100\u00b0C, Accuracy: \u00b10.1\u00b0<br \/>\n\u2022\u00a0Communicate with Digital Power Meter to display the Voltage, Current, Power and Power factor<br \/>\n\u2022\u00a0Connect with PC via USB, English version software can be run under WinXP, Win7 and Win8<\/p>\n<p><strong>Please visit this page to view the latest version <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/high-precision-spectroradiometer-integrating-sphere-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-2 High Precision Spectroradiometr Integrating Sphere System<\/a>.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>This Integrated Sphere Spectrophotometer Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry. Standard: CIE [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3430,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[111],"class_list":["post-2354","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lpce-1"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2354","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/comments?post=2354"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2354\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media\/3430"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media?parent=2354"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/categories?post=2354"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/tags?post=2354"}],"curies":[{"name":"\uc6cc\ub4dc\ud504\ub808\uc2a4","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}