{"id":2471,"date":"2025-06-19T19:36:10","date_gmt":"2025-06-19T11:36:10","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/uv-aging-test-chamber\/"},"modified":"2025-07-01T17:13:28","modified_gmt":"2025-07-01T09:13:28","slug":"uv-aging-test-chamber","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ko\/%ec%a0%9c%ed%92%88\/uv-aging-test-chamber\/","title":{"rendered":"ISO 4892-1 \uc790\uc678\uc120 \ub0b4\ud6c4\uc131 \ub178\ud654 \uc2dc\ud5d8 \ucc54\ubc84"},"content":{"rendered":"<p>UV aging test Chamber is designed for evaluating the resistant performance of non-metallic materials, organic materials (plastics, paints, coatings, rubbers, etc.) under the specified conditions such as sunlight, temperature, and other climatic conditions. It creates a man-made testing environment imitating the natural light source such as sunlight and other damages in the nature, such as rain and dew damage, to impose on the materials and to assess the degree of color changing and fading under the accelerated environment conditions. The chamber provides the best UV sunlight simulation, and is easy to use and operate.<\/p>\n<p><strong>\ud45c\uc900<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/BS-EN-ISO-4892-1-2001-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ISO 4892-1<\/a> \u201cPlastics Methods of exposure to laboratory light sources Part 1: General guidance\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2020\/02\/ISO-4892-3-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ISO 4892-3 <\/a>\u201cPlastics Methods of exposure to laboratory light sources Part 3: Fluorescent UV lamps\u201d<br \/>\nASTMG53 \u201cStandard Practice for Operating Light-and Water-Exposure Apparatus (Fluorescent UV-Condensation Type) for Exposure of Nonmetallic Materials.\u201d<br \/>\nGB\/T 16585-1996 \u201cRubber,vulcanized\u2013Test method of resistance to artificial weathering (Fluorescent UV lamp)\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-16422.3-1997-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T 16422.3-1997<\/a> \u201cPlastics-Methods of exposure to labory light sources- Part3:Fluorescent UV lamps\u201d<\/p>\n<p><strong>Main configuration:<\/strong><br \/>\n\u2022 UV aging test chamber Working room: \u00a0550*1140*450mm (L*W*H)<br \/>\n\u2022 External dimension: 650*1300*1700mm (L*W*H)<br \/>\n\u2022\u00a0Material (internal &amp; external): 304 SUS stainless steel<br \/>\n\u2022\u00a0Sample holder: Aluminum alloy frame plate<br \/>\n\u2022\u00a0Controller: Color touch-screen programmable controller<br \/>\n\u2022 Irradiation lamp: UVA-340 (Option is UVB-313)<br \/>\n\u2022\u00a0Protecting power supply from circuit overload, short circuit, over-temperature and water shortage by residual-current circuit breaker (RCCB)<\/p>\n<p><strong>\uc0ac\uc591:<\/strong><br \/>\n\u2022 UV Aging Test Chamber Temperature range: RT+40\u2103~70\u2103; Temperature uniformity: \u00b11\u2103; Temperature fluctuation: \u00b10.5\u2103<br \/>\n\u2022 Humidity range: \u226590% RH<br \/>\n\u2022 Distance between lamps: 70mm; Distance between sample and lamp: 50\u00b13mm<br \/>\n\u2022 Irradiance: 0~1.0W\/m2 adjustable; Lamp: L=1200\/40W, 8pcs<br \/>\n\u2022\u00a0Standard size of testing sample: 75\u00d7290mm (Special size can be customized)<br \/>\n\u2022 Effective irradiation area: 900\u00d7210mm<br \/>\n\u2022 Temperature, lighting, condensation, spraying and test cycle are adjustable<br \/>\n\u2022\u00a0Controller: color touch-screen programmable controller<br \/>\n\u2022 Way of temperature control: PID + SSR<br \/>\n\u2022 Sink depth: 25mm auto control<br \/>\n\u2022\u00a0Testing time: 0~999H (adjustable)<br \/>\n\u2022\u00a0Temperature of irradiation blackboard: 50\u2103~70\u2103<br \/>\n\u2022\u00a0Standard sample holder: 24 inches<br \/>\n\u2022\u00a0The tester is equipped with automatic spraying function<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-uv-263ls-uv-aging-test-chamber-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN UV-263LS UV Aging Test Chamber \u2013 After-sales Frequently Asked Questions (FAQ)<\/span><\/a><br \/>\n<\/strong>LISUN UV-263LS UV Aging Test Chamber were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>UV aging test Chamber is designed for evaluating the resistant performance of non-metallic materials, organic materials (plastics, paints, coatings, rubbers, etc.) under the specified conditions such as sunlight, temperature, and other climatic conditions. It creates a man-made testing environment imitating the natural light source such as sunlight and other damages in the nature, such as [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3737,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[225],"class_list":["post-2471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-uv-263ls"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/comments?post=2471"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2471\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media\/3737"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media?parent=2471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/categories?post=2471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/tags?post=2471"}],"curies":[{"name":"\uc6cc\ub4dc\ud504\ub808\uc2a4","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}