{"id":2524,"date":"2025-06-19T19:36:32","date_gmt":"2025-06-19T11:36:32","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/hbm-mm-esd-simulators-for-ic-testing\/"},"modified":"2025-06-25T17:58:30","modified_gmt":"2025-06-25T09:58:30","slug":"hbm-mm-esd-simulators-for-ic-testing","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ko\/%ec%a0%9c%ed%92%88\/hbm-mm-esd-simulators-for-ic-testing\/","title":{"rendered":"IC \ud14c\uc2a4\ud2b8\uc6a9 HBM\/MM ESD \uc2dc\ubbac\ub808\uc774\ud130"},"content":{"rendered":"<p>ESD-883D ESD Simulators for IC Testing is specially designed for the characteristics and requirements of the electrostatic discharge immunity test of the Human Body Model (HBM) discharge and the Machine Model (MM) discharge. It can test the electrostatic immunity of semiconductor devices such as LED chips, transistors and ICs. It is designed and manufactured in accordance with the requirements of the following corresponding standards, and fully meets the most stringent electrostatic voltage requirements in the following standards.<\/p>\n<table style=\"width: 100.339%; height: 497px;\" width=\"802\">\n<tbody>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; vertical-align: middle;\" width=\"148\"><strong>Discharge Model<\/strong><\/td>\n<td style=\"height: 28px; vertical-align: middle;\" width=\"654\"><strong>International Standards<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 303px; vertical-align: middle;\" rowspan=\"6\" width=\"148\">Human Body Model<br \/>\n(HBM)<\/td>\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">MIL-STD-883 Method 3015 \u201cTest Method Standard for Microcircuits-Electrostatic Discharge Susceptibility Testing\u201d<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">ANSI\/ESD STM5.1-2007 \u201cStandard Test Method for Electrostatic Discharge Sensitivity Testing-Human Body Model (HBM)-Component Level\u201d<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">ANSI\/ESDA\/JEDEC JS-001-2024 \u201cElectrostatic Discharge (ESD) Sensitivity Testing-Human-Body Model (HBM)-Component Level\u201d<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">IEC 60749-26:2018 \u201cSemiconductor devices-Mechanical and climatic test methods-Part 26: Electrostatic discharge (ESD) sensitivity testing-Human body model (HBM)\u201d<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; vertical-align: middle;\" width=\"654\">AEC-Q100-002 \u201cFailure Mechanism Based Stress Test Qualification for Integrated Circuits-ESD HBM Test\u201d<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">EIA\/JESD22-A114-A \u201cTest Method for Electrostatic Discharge Sensitivity Testing-Human Body Model (HBM)\u201d<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 166px; vertical-align: middle;\" rowspan=\"4\" width=\"148\">Machine Model<br \/>\n(MM)<\/td>\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">ANSI\/ESD STM5.2-2013 \u201cStandard Test Method for Electrostatic Discharge Sensitivity Testing-Machine Model (MM)-Component Level\u201d<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 55px; vertical-align: middle;\" width=\"654\">IEC 60749-27:2012 \u201cSemiconductor devices-Mechanical and climatic test methods-Part 27: Electrostatic discharge (ESD) sensitivity testing-Machine model (MM)\u201d<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; vertical-align: middle;\" width=\"654\">AEC-Q100-003 \u201cFailure Mechanism Based Stress Test Qualification for Integrated Circuits-ESD MM Test\u201d<\/td>\n<\/tr>\n<tr style=\"height: 28px;\">\n<td style=\"height: 28px; vertical-align: middle;\" width=\"654\">EIA\/JESD22-A115-A \u201cTest Method for Electrostatic Discharge Sensitivity Testing-Machine Model (MM)\u201d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\ud2b9\uc9d5:<\/strong><br \/>\n\u2022 Color LCD touchscreen, easy to operate.<br \/>\n\u2022 Output voltage with high accuracy and stable performance<br \/>\n\u2022 Intelligent programmable high-voltage power supply, high-voltage over-voltage, over-current, short-circuit protection<br \/>\n\u2022 With self-diagnosis function, can intelligently judge abnormal high voltage output<br \/>\n\u2022 Cost-effective: The main components are all imported, with high accuracy and low failure rate.<\/p>\n<p><strong>\uc0ac\uc591:<\/strong><strong>\u00a0<\/strong><\/p>\n<table style=\"width: 99.9423%; height: 372px;\" width=\"516\">\n<tbody>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"164\">\ucd9c\ub825 \uc804\uc555<\/td>\n<td width=\"176\">Human Body Model\uff08HBM\uff09<\/td>\n<td width=\"176\">Machine Mode (MM)<\/td>\n<\/tr>\n<tr>\n<td width=\"176\">0.05~8kV\u00b15\uff05<\/td>\n<td width=\"176\">50~800V\u00b15\uff05<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">Output polarity<\/td>\n<td colspan=\"2\" width=\"352\">\ud3ec\uc9c0\ud2f0\ube0c, \ub124\uac70\ud2f0\ube0c \ub610\ub294 \uc790\ub3d9 \uc804\ud658<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"100\">\ud2b8\ub9ac\uac70 \ubaa8\ub4dc<\/td>\n<td width=\"64\">Single<\/td>\n<td colspan=\"2\" width=\"352\">Single discharge<\/td>\n<\/tr>\n<tr>\n<td width=\"64\">Count<\/td>\n<td colspan=\"2\" width=\"352\">Discharge according to the set discharge times<\/td>\n<\/tr>\n<tr>\n<td width=\"64\">Other<\/td>\n<td colspan=\"2\" width=\"352\">Host self-triggering<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">Discharge mode<\/td>\n<td colspan=\"2\" width=\"352\">HBM and MM<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">Discharge Interval<\/td>\n<td colspan=\"2\" width=\"352\">1~99s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">Discharge Number<\/td>\n<td colspan=\"2\" width=\"352\">1~999<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">Discharge Capacitance<\/td>\n<td width=\"176\">100pF\u00b110\uff05<\/td>\n<td width=\"176\">200pF\u00b110\uff05<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">Discharge Resistance<\/td>\n<td width=\"176\">1500\u03a9\u00b110\uff05<\/td>\n<td width=\"176\">0\u03a9\u00b110\uff05<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"164\">\uc791\ub3d9 \uc804\ub825<\/td>\n<td colspan=\"2\" width=\"352\">AC 100~240V, 50\/60Hz, 300W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: ESD-883D can share a host with <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/ansi-esda-jedec-js-002-2014-cdm-esd-test-system.html\" target=\"_blank\" rel=\"noopener\">ESD-CDM Charged Device Mode (CDM) ESD Testing for IC<\/a> to test HBM, MM and CDM at the same time (LISUN model: ESD-883D\/ESD-CDM)<\/p>","protected":false},"excerpt":{"rendered":"<p>ESD-883D ESD Simulators for IC Testing is specially designed for the characteristics and requirements of the electrostatic discharge immunity test of the Human Body Model (HBM) discharge and the Machine Model (MM) discharge. It can test the electrostatic immunity of semiconductor devices such as LED chips, transistors and ICs. It is designed and manufactured in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3227,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[277],"class_list":["post-2524","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-esd-883d"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2524","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/comments?post=2524"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2524\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media\/3227"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media?parent=2524"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/categories?post=2524"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/tags?post=2524"}],"curies":[{"name":"\uc6cc\ub4dc\ud504\ub808\uc2a4","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}