{"id":2764,"date":"2025-06-19T19:39:28","date_gmt":"2025-06-19T11:39:28","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/nf-c-61-314-of-french-standard-plugs-and-socket-outlets-adaptors-gauges\/"},"modified":"2025-06-25T15:27:40","modified_gmt":"2025-06-25T07:27:40","slug":"nf-c-61-314-of-french-standard-plugs-and-socket-outlets-adaptors-gauges","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ko\/%ec%a0%9c%ed%92%88\/nf-c-61-314-of-french-standard-plugs-and-socket-outlets-adaptors-gauges\/","title":{"rendered":"NF C 61-314 of French Standard Plugs and Socket Outlets Adaptors Gauges"},"content":{"rendered":"<p>The French Standard Plugs and Socket Outlets Adaptors Gauges is strictly designed and manufactured according to the relevant standard requirements of <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/NFC61-314-2008.pdf\" target=\"_blank\" rel=\"noopener\">NF C 61-314<\/a>.<\/p>\n<p>This plug and socket test gauge is mainly used to test and inspect whether the structure and size of plugs and sockets conform to NF C 61-314 standards. And the mainly application industries is electronics, electrical appliances, plugs and sockets and other similar areas.<\/p>\n<p><strong>\uc0ac\uc591:<\/strong><\/p>\n<table style=\"width: 100.1%; height: 419px;\" width=\"615\">\n<tbody>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"138\"><strong>LISUN \ubaa8\ub378<\/strong><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\"><strong>\uc81c\ud488 \uc0ac\uc591<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/gauges-figure-c1-of-nf-c-61-314.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C1<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">NF C 61-314 C1 Gauge for checking impossibility of single-pole insertion of plugs (6A\/16A)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/gauges-figure-c2-of-nf-c-61-314.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C2<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">NF C 61-314 C2 Gauges for size of entry holes for plug pins (5.3mm\/5.8mm)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"138\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/nf-c-61-314-c3-calibre-pour-verifier-la-distance-jusquau-premier-point-de-contact.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C3<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">NF C 61-314 C3 Gauges for distance to point of first contact ( 5.75\/5.0\/5.25mm, 6A; 5.45\/5.60\/5.75mm, 16A)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/gauges-figure-c4a-c4b-c4c-and-c4d-of-nf-c-61-314.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C4ABCD<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">Gauges for minimum opening contact tubes<br \/>\nNF C 61-314 C4A (3.94mm, 300\/150g;<br \/>\nNF C 61-314 C4B (3.80mm, 400\/200g);<br \/>\nNF C 61-314 C4C\u00a0 (4.60mm, 400\/200g);<br \/>\nNF C 61-314 C4D\u00a0 (4.86mm, 2500g)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"138\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/nf-c-61-314-c7.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C5<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">NF C 61-314 C5 Gauge for acceptance of two-pole plugs (6A\/16A)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/gauges-figure-c6-of-nf-c-61-314.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C6<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">NF C 61-314 C6 Gauge for maximum opening of contact tubes(16A)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"138\"><a href=\"https:\/\/www.lisungroup.com\/products\/gauges-for-plugs-and-sockets\/des-broches-of-nf-c-61-314-c7.html\" target=\"_blank\" rel=\"noopener\">GNGPL-631C7<\/a><\/td>\n<td style=\"vertical-align: middle; text-align: center;\" width=\"477\">NF C 61-314 C7 Gauge for pin spacing(6A\/16A)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>The French Standard Plugs and Socket Outlets Adaptors Gauges is strictly designed and manufactured according to the relevant standard requirements of NF C 61-314. This plug and socket test gauge is mainly used to test and inspect whether the structure and size of plugs and sockets conform to NF C 61-314 standards. And the mainly [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3320,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[476],"class_list":["post-2764","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-gngpl-61314"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/comments?post=2764"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2764\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media\/3320"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media?parent=2764"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/categories?post=2764"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/tags?post=2764"}],"curies":[{"name":"\uc6cc\ub4dc\ud504\ub808\uc2a4","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}