{"id":2842,"date":"2025-06-19T19:40:57","date_gmt":"2025-06-19T11:40:57","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-63294-iec-60245-1-iec-60227-1-static-flexibility-test-machine-for-flexible-cables\/"},"modified":"2025-06-25T13:40:55","modified_gmt":"2025-06-25T05:40:55","slug":"iec-63294-iec-60245-1-iec-60227-1-static-flexibility-test-machine-for-flexible-cables","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ko\/%ec%a0%9c%ed%92%88\/iec-63294-iec-60245-1-iec-60227-1-static-flexibility-test-machine-for-flexible-cables\/","title":{"rendered":"IEC 63294 IEC 60245-1 IEC 60227-1 Static Flexibility Test Machine for Flexible Cables"},"content":{"rendered":"<p>The WDT-3 Static Flexibility Test Machine for Flexible Cables fully meet fully meet IEC 60245-1:2008 Clause 5.6.3.2 (GB\/T 5013.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60245-2 Clause 3.2 Figure 2 (GB\/T 5013.2-2008 Clause 3.2 Figure 2)), IEC 60227-1:2024 Clause 5.6.3.2 (GB\/T 5023.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60227-2:2008 Clause 3.2 Figure 2 (GB\/T 5023.2-2008 Clause 3.2 Figure 2)). It used for the Static Flexibility Test of Flexible Cables in the mechanical strength test (Note: This test is not suitable for cables with more than two concentric layers with a conductor nominal cross-section of more than 18 cores).<\/p>\n<p>Test principle: The 3m long sample is initially 200mm at the clamping end, and then one end is moved to bend the Flexible Cable into a standard U shape, and the distance between the two clamping ends is measured.<\/p>\n<p><strong>\ud45c\uc900:<br \/>\n<\/strong>IEC 63294 (IEC 60245-2, IEC 60227-2, GB\/T 5013.2, GB\/T 5023.2) \u201cTest methods for electric cables with rated voltages up to and including 450\/750 V\u201d<br \/>\nIEC 60245-1 (GB\/T 5013.1) \u201cRubber insulated cables \u2013 Rated voltages up to and including 450\/750 V \u2013 Part 1: General requirements\u201d Clause 5.6.3.2<br \/>\nIEC 60227-1 (GB\/T 5023.1) \u201cPolyvinyl chloride insulated cables of rated voltages up to and including 450\/750 V \u2013 Part 1: General requirements\u201d Clause 5.6.3.2<\/p>\n<p><strong>\uc0ac\uc591:<\/strong><br \/>\n\u2022 Flexural length: 200 -1500(mm)<br \/>\n\u2022 Sample outer diameter: \u03c66 \u2013 32(mm)<br \/>\n\u2022 Sample length: 3000\u00b15% (mm)<br \/>\n\u2022 Height above ground: 1500mm<br \/>\n\u2022 Overall dimensions (length*width*height): 2000*400*1800mm<\/p>\n<div id=\"attachment_15723\" class=\"wp-caption aligncenter\" style=\"width: 624px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-15723 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-1-2007-Clause-5.6.3.2.png\" sizes=\"(max-width: 614px) 100vw, 614px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-1-2007-Clause-5.6.3.2.png 614w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-1-2007-Clause-5.6.3.2-400x79.png 400w\" alt=\"\" width=\"614\" height=\"122\" aria-describedby=\"caption-attachment-15723\" title=\"\"><\/p>\n<p id=\"caption-attachment-15723\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60245-1: 2007 Clause 5.6.3.2<\/span><\/p>\n<\/div>\n<div id=\"attachment_15724\" class=\"wp-caption aligncenter\" style=\"width: 619px;\">\n<p><img decoding=\"async\" class=\"wp-image-15724 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-2-1998-Clause-3.2-Figure-2.png\" sizes=\"(max-width: 609px) 100vw, 609px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-2-1998-Clause-3.2-Figure-2.png 609w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-2-1998-Clause-3.2-Figure-2-311x400.png 311w\" alt=\"\" width=\"609\" height=\"784\" aria-describedby=\"caption-attachment-15724\" title=\"\"><\/p>\n<p id=\"caption-attachment-15724\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60245-2: 1998 Clause 3.2 Figure 2<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The WDT-3 Static Flexibility Test Machine for Flexible Cables fully meet fully meet IEC 60245-1:2008 Clause 5.6.3.2 (GB\/T 5013.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60245-2 Clause 3.2 Figure 2 (GB\/T 5013.2-2008 Clause 3.2 Figure 2)), IEC 60227-1:2024 Clause 5.6.3.2 (GB\/T 5023.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60227-2:2008 Clause 3.2 Figure 2 (GB\/T 5023.2-2008 Clause 3.2 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3749,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[536],"class_list":["post-2842","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-wdt-3"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/comments?post=2842"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/posts\/2842\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media\/3749"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/media?parent=2842"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/categories?post=2842"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ko\/wp-json\/wp\/v2\/tags?post=2842"}],"curies":[{"name":"\uc6cc\ub4dc\ud504\ub808\uc2a4","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}