Czat online

+8615317905991

Test przewodu jarzeniowego oświetlenia awaryjnego

Spis treści

Introduction to Glow-Wire Testing in Emergency Lighting Systems

Emergency lighting systems are critical for ensuring safety in low-visibility or hazardous conditions, particularly in commercial, industrial, and residential environments. Regulatory standards mandate rigorous flammability testing to assess material resistance to ignition and flame propagation. The glow-wire test, governed by IEC 60695-2-10 through IEC 60695-2-13, evaluates the fire hazard potential of insulating materials, enclosures, and components when exposed to high temperatures.

Ten LISUN Aparatura do badania żarowym drutem ZRS-3H is a precision instrument designed to conduct these assessments with repeatability and compliance to international standards. This article examines the testing methodology, industry applications, and the technical superiority of the ZRS-3H in ensuring material safety across multiple sectors.

Technical Specifications of the LISUN ZRS-3H Glow-Wire Test Apparatus

The ZRS-3H is engineered for high-precision thermal testing, featuring:

  • Zakres temperatur: 300°C to 1000°C (±2°C accuracy)
  • Glow-Wire Dimensions: 4mm diameter nickel-chromium wire, compliant with IEC 60695-2-10
  • Test Force Adjustment: 1.0N ± 0.1N (adjustable via calibrated weights)
  • Uchwyt na próbki: Adjustable positioning for vertical or horizontal orientation
  • Timer Function: 0–999.9s (±0.1s resolution) for ignition duration measurement
  • Funkcje bezpieczeństwa: Overheat protection, automatic cut-off, and fume extraction compatibility

The apparatus supports testing under IEC, EN, UL, and GB standards, ensuring global applicability.

Testing Principle and Methodology

The glow-wire test simulates thermal stress caused by overheated components or electrical faults. A preheated wire is applied to the test specimen under controlled force and duration. Observations include:

  1. Ignition Time: Duration until sustained flaming occurs.
  2. Flame Persistence: Post-application burning duration.
  3. Material Behavior: Dripping, deformation, or carbonization.

Compliance thresholds vary by application:

  • Household Appliances (IEC 60335-1): ≤30s flame persistence at 750°C.
  • Automotive Electronics (ISO 20653): No ignition at 850°C.
  • Lighting Fixtures (IEC 60598-1): Non-propagation at 650°C.

Przypadki użycia specyficzne dla branży

1. Electrical and Electronic Equipment

Circuit boards, connectors, and insulating materials must resist thermal degradation. The ZRS-3H verifies flame-retardant properties in power supplies and control modules.

2. Household Appliances

Switches, thermostats, and motor housings undergo testing at 550°C–850°C to prevent fire risks in dishwashers, refrigerators, and HVAC systems.

3. Automotive Electronics

EV battery enclosures and infotainment systems are tested at elevated temperatures to meet ISO 20653 and LV 312 requirements.

4. Medical Devices

Polymer casings for ventilators and imaging equipment must self-extinguish within 15s at 650°C per IEC 60601-1.

5. Aerospace and Aviation

Cabin lighting and wiring insulation are subjected to 960°C tests to comply with FAA flammability regulations.

Competitive Advantages of the ZRS-3H

  1. Calibration Stability: Proprietary PID temperature control minimizes drift.
  2. Modułowa konstrukcja: Interchangeable fixtures accommodate diverse specimen geometries.
  3. Rejestrowanie danych: Integrated software records temperature curves and ignition events for audit trails.
  4. Cross-Industry Compliance: Validates materials against IEC, UL, and GB/T 5169.10-2017.

Standards Referenced in Glow-Wire Testing

StandardApplication Scope
IEC 60695-2-10Basic glow-wire apparatus and test procedure
IEC 60695-2-11Palność produktów końcowych
UL 746AMateriały polimerowe - łatwopalność
GB/T 5169.10-2017Chiński odpowiednik normy IEC 60695-2-10

Sekcja FAQ

P1: Co odróżnia ZRS-3H od standardowych testerów drutu żarowego?
ZRS-3H oferuje doskonałą stabilność temperaturową (±2°C), zautomatyzowaną aplikację siły i zgodność z wieloma międzynarodowymi standardami, zapewniając powtarzalne wyniki.

P2: Jak często należy wymieniać element żarowy?
Drut niklowo-chromowy powinien być sprawdzany przed każdą serią testów i wymieniany, jeśli utlenienie lub odkształcenie przekracza 0,5 mm odchylenia.

P3: Czy ZRS-3H może testować próbki zorientowane pionowo?
Tak, regulowany uchwyt umożliwia ustawienie zarówno w poziomie, jak i w pionie, zgodnie z wymaganiami normy IEC 60695-2-12.

P4: Jakie środki ostrożności są konieczne podczas testów?
Operatorzy muszą korzystać z odciągu oparów, rękawic odpornych na wysoką temperaturę i przestrzegać normy ASTM D3874 dotyczącej protokołów bezpieczeństwa w laboratorium.

P5: Czy urządzenie nadaje się do testowania produkcji wielkoseryjnej?
Dzięki szybkim cyklom nagrzewania (≤3 min do 1000°C) i automatycznemu rejestrowaniu, ZRS-3H jest zoptymalizowany dla laboratoriów kontroli jakości i placówek badawczo-rozwojowych.

Ta analiza techniczna podkreśla rolę ZRS-3H w łagodzeniu zagrożeń pożarowych w różnych branżach, wzmacniając jego pozycję jako punktu odniesienia dla walidacji bezpieczeństwa materiałów.