{"id":2328,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/portable-ccd-spectroradiometer-2\/"},"modified":"2025-07-03T14:51:11","modified_gmt":"2025-07-03T06:51:11","slug":"przenosny-spektroradiometr-ccd-2","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/przenosny-spektroradiometr-ccd-2\/","title":{"rendered":"R\u0119czny spektroradiometr"},"content":{"rendered":"<p>Przeno\u015bny spektroradiometr CCD LED kolorymetryczny wyst\u0119puje w nast\u0119puj\u0105cych wersjach, kt\u00f3re umo\u017cliwiaj\u0105 pomiar r\u00f3\u017cnych parametr\u00f3w:<strong><br \/>\n<\/strong><\/p>\n<table style=\"width: 100.373%; height: 792px;\" width=\"709\">\n<tbody>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">Model LISUN<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Funkcjonowa\u0107<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">Zakres fal<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 151px;\" width=\"111\">LMS-6000<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 151px;\" width=\"497\">Nat\u0119\u017cenie o\u015bwietlenia, E(Fc), Ee(W\/m2), Tc (K), skorelowana temperatura barwowa Duv (CCT), wsp\u00f3\u0142rz\u0119dne chromatyczno\u015bci, CRI, TM-30 (Rf, Rg), czysto\u015b\u0107, szczytowa d\u0142ugo\u015b\u0107 fali, dominuj\u0105ca d\u0142ugo\u015b\u0107 fali, po\u0142owa pasma, \u015brodkowa d\u0142ugo\u015b\u0107 fali, centroidalna d\u0142ugo\u015b\u0107 fali, ca\u0142kowita r\u00f3\u017cnica barw, r\u00f3\u017cnica jasno\u015bci, stopie\u0144 czerwieni i zieleni, stopie\u0144 \u017c\u00f3\u0142ci i b\u0142\u0119kitu, r\u00f3\u017cnica CCT, wykres SDCM, wykres widma. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000-Test-Report.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 151px;\" width=\"101\">380-780 nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000C<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Parametry LMS-6000 bez oprogramowania PC i TM-30 (Rf, Rg)<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780 nm<\/td>\n<\/tr>\n<tr style=\"height: 91px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 91px;\" width=\"111\">LMS-6000UV<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 91px;\" width=\"497\">Nat\u0119\u017cenie promieniowania UV-A, UV-B, UV-C i ca\u0142kowite promieniowanie UV (0,1\u2013500 000 \u03bcW\/cm\u00b2 \u00b10,01 \u03bcW\/cm\u00b2), nat\u0119\u017cenie promieniowania UV, widmo UV, dominuj\u0105ca d\u0142ugo\u015b\u0107 fali, sygna\u0142 szczytowy, pocz\u0105tkowa d\u0142ugo\u015b\u0107 fali, ko\u0144cowa d\u0142ugo\u015b\u0107 fali. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lms-6000uv-test-report.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000UV<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 91px;\" width=\"101\">200-400nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000F<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Parametry LMS-6000 + test migotania. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000F.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000F<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780 nm<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 151px;\" width=\"111\">LMS-6000L<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 151px;\" width=\"497\">Jasno\u015b\u0107 (0,1\u2013500 000 cd\/m\u00b2\u00b10,1 cd\/m\u00b2), fL, Tc (K), skorelowana temperatura barwowa Duv (CCT), wsp\u00f3\u0142rz\u0119dne chromatyczno\u015bci, CRI, TM-30 (Rf, Rg), czysto\u015b\u0107, szczytowa d\u0142ugo\u015b\u0107 fali, dominuj\u0105ca d\u0142ugo\u015b\u0107 fali, po\u0142owa pasma, \u015brodkowa d\u0142ugo\u015b\u0107 fali, centroidalna d\u0142ugo\u015b\u0107 fali, ca\u0142kowita r\u00f3\u017cnica kolor\u00f3w, r\u00f3\u017cnica jasno\u015bci, stopie\u0144 czerwieni i zieleni, stopie\u0144 \u017c\u00f3\u0142ci i b\u0142\u0119kitu, r\u00f3\u017cnica CCT, wykres SDCM, wykres widma. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000L.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000L<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 151px;\" width=\"101\">380-780 nm<\/td>\n<\/tr>\n<tr style=\"height: 61px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 61px;\" width=\"111\">LMS-6000B<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 61px;\" width=\"497\">Parametry LMS-6000 + Nat\u0119\u017cenie promieniowania wa\u017cone zagro\u017ceniem \u015bwiat\u0142em niebieskim zgodnie z GB\/T20145, CIE S009\/E:2002<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 61px;\" width=\"101\">350-800nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000BF<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Parametry LMS-6000B + test migotania. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000BF.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000BF<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">350-800nm<\/td>\n<\/tr>\n<tr style=\"height: 91px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 91px;\" width=\"111\">LMS-6000P<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 91px;\" width=\"497\">Parametry LMS-6000 + PAR, PPFD (0,1\u2013500 000 umol\/m\u00b2.s \u00b10,01 umol\/m\u00b2.s), YPFD, nat\u0119\u017cenie promieniowania niebiesko-fioletowego Eb, nat\u0119\u017cenie promieniowania \u017c\u00f3\u0142to-zielonego Ey, nat\u0119\u017cenie promieniowania czerwono-pomara\u0144czowego Er, stosunek promieniowania czerwonego do niebieskiego Erb_Ratio. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000P.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000P<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 91px;\" width=\"101\">350-850nm<\/td>\n<\/tr>\n<tr style=\"height: 61px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 61px;\" width=\"111\">LMS-6000S<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 61px;\" width=\"497\">Parametry LMS-6000P + Nat\u0119\u017cenie promieniowania wa\u017cone zagro\u017ceniem \u015bwiat\u0142em niebieskim zgodnie z GB\/T20145, CIE S009\/E:2002<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 61px;\" width=\"101\">350-950nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000SF<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Pe\u0142ne funkcje: parametry LMS-6000S + test migotania. Kliknij tutaj, aby zobaczy\u0107 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000SF.pdf\" target=\"_blank\" rel=\"noopener\">Raport z testu LMS-6000SF<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">350-950nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000I<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Sterowanie wej\u015bciem i wyj\u015bciem przez RS485<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Renderowanie kolor\u00f3w bia\u0142ych \u017ar\u00f3de\u0142 \u015bwiat\u0142a LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Metoda pomiaru i okre\u015blania w\u0142a\u015bciwo\u015bci oddawania barw przez \u017ar\u00f3d\u0142a \u015bwiat\u0142a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/OPTICAL-ENGINEERING-49-3-033602-2010-COLOR-QUALITY-SCALE-CQS-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Optical-Engineering-49-3-033602<\/a> \u201dSkala jako\u015bci kolor\u00f3w\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEEE-2015-STANDARDS-1789-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEEE<\/a>. \"Zalecane praktyki w zakresie modulacji pr\u0105du w diodach LED o wysokiej jasno\u015bci w celu ograniczenia zagro\u017ce\u0144 dla zdrowia widz\u00f3w\"<\/p>\n<p><strong>Specyfikacja miernika chrominancji:<\/strong><br \/>\n\u2022 Rozdzielczo\u015b\u0107 widmowa: \u00b10,2 nm, Powtarzalno\u015b\u0107: \u00b10,5 nm<br \/>\n\u2022 Dok\u0142adno\u015b\u0107 wsp\u00f3\u0142rz\u0119dnej chromatyczno\u015bci (\u0394x, \u0394y): \u00b10,005<br \/>\n\u2022 Skorelowana temperatura barwowa CCT: 1500K ~ 100000K (\u00b10,6%)<br \/>\n\u2022 Zakres nat\u0119\u017cenia o\u015bwietlenia: 0,1~500 000 lx (\u00b10,1 lx)<br \/>\n\u2022 Ekran LCD: 5-calowy pojemno\u015bciowy ekran dotykowy IPS o wysokiej rozdzielczo\u015bci i rozdzielczo\u015bci do 480*854<br \/>\n\u2022 Z akumulatorem litowo-jonowym o pojemno\u015bci 4000 mAh, kt\u00f3ry mo\u017ce pracowa\u0107 nieprzerwanie przez 20 godzin<br \/>\n\u2022 Wymiary: 135 mm * 80 mm * 23 mm<br \/>\n\u2022 Pojemno\u015b\u0107 pami\u0119ci masowej<span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">:8 GB, mo\u017ce przechowywa\u0107 od 5000 do 100 000 raport\u00f3w testowych<\/span><\/span><\/span><br \/>\n\u2022 Pod\u0142\u0105cz do komputera za pomoc\u0105 kabla USB. Oprogramowanie w wersji angielskiej dzia\u0142a w systemach Win7, Win8, Win10, Win11.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-3689 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1.jpg\" sizes=\"(max-width: 2880px) 100vw, 2880px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1.jpg 2880w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-400x119.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-768x228.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-1920x569.jpg 1920w\" alt=\"Raport z testu przeno\u015bnego kolorymetru LED i spektroradiometru CCD LMS-6000\" width=\"2880\" height=\"854\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-new-version-lms-6000-portable-ccd-spectroradiometer-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">Przeno\u015bny spektroradiometr CCD LISUN LMS-6000 \u2013 Najcz\u0119\u015bciej zadawane pytania (FAQ) dotycz\u0105ce obs\u0142ugi posprzeda\u017cowej<\/span><\/a><br \/>\n<\/strong>Przeno\u015bny spektroradiometr CCD LISUN LMS-6000 jest dost\u0119pny na rynku od ponad 10 lat. Zesp\u00f3\u0142 serwisowy in\u017cynier\u00f3w LISUN podsumowa\u0142 ju\u017c wi\u0119kszo\u015b\u0107 pyta\u0144 i odpowiedzi dotycz\u0105cych obs\u0142ugi posprzeda\u017cowej w powy\u017cszym linku. Prosimy o uwa\u017cne zapoznanie si\u0119 z nim, poniewa\u017c w przypadku pyta\u0144 podczas u\u017cytkowania urz\u0105dze\u0144 mo\u017cna samodzielnie rozwi\u0105za\u0107 wi\u0119kszo\u015b\u0107 problem\u00f3w. LISUN b\u0119dzie na bie\u017c\u0105co aktualizowa\u0107 t\u0119 stron\u0119, a wi\u0119cej odpowiedzi na cz\u0119sto zadawane pytania mo\u017cna znale\u017a\u0107 w tym linku.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters: LISUN Model Function Wave Range LMS-6000 illuminance, E(Fc), Ee(W\/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, TM-30 (Rf, Rg), Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3419,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[42],"class_list":["post-2328","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-6000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2328"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2328\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/3419"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2328"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2328"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}