{"id":2333,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/goniophotometer-with-rotating-mirror\/"},"modified":"2025-06-27T10:24:48","modified_gmt":"2025-06-27T02:24:48","slug":"goniophotometer-with-rotating-mirror","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/goniophotometer-with-rotating-mirror\/","title":{"rendered":"Goniofotometr z obrotowym lustrem"},"content":{"rendered":"<p>LSG-2000 <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/\" target=\"_blank\" rel=\"noopener\">Goniofotometr<\/a> with Rotating Mirror is also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The darkroom can be designed according to the customer\u2019s existing room size. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.<\/p>\n<div id=\"attachment_3595\" class=\"wp-caption aligncenter\" style=\"width: 2011px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3595 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle.jpg\" sizes=\"(max-width: 2001px) 100vw, 2001px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle.jpg 2001w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-400x117.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-768x225.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-1920x562.jpg 1920w\" alt=\"\" width=\"2001\" height=\"586\" aria-describedby=\"caption-attachment-3595\" title=\"\"><\/p>\n<p id=\"caption-attachment-3595\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">LSG-2000 Moving Mirror Goniophotometer Principle<\/span><\/p>\n<\/div>\n<div id=\"product-tab\" class=\"woocommerce-tabs woocommerce-tabs-mnuoobsanjog9tqcdrnax9f3ei9bm4g\">\n<div class=\"resp-tabs-container\">\n<div id=\"tab-description\" class=\"tab-content resp-tab-content resp-tab-content-active\" aria-labelledby=\"tab_item-0\">\n<div id=\"attachment_6328\" class=\"wp-caption aligncenter\" style=\"width: 2049px;\">\n<p><img decoding=\"async\" class=\"wp-image-6328 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1.jpg\" sizes=\"(max-width: 2039px) 100vw, 2039px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1.jpg 2039w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-400x117.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-768x224.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-1920x561.jpg 1920w\" alt=\"LSG-2000 Moving Detector Goniophotometer Dark Room\" width=\"2039\" height=\"596\" aria-describedby=\"caption-attachment-6328\" title=\"\"><\/p>\n<p id=\"caption-attachment-6328\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">LSG-2000 Moving Detector Goniophotometer Dark Room<\/span><\/p>\n<\/div>\n<p><strong>Pomiar:<br \/>\n<\/strong>Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution (Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.<\/p>\n<p><strong>Standard\uff1a<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Pomiary optyczne i elektryczne p\u00f3\u0142przewodnikowych produkt\u00f3w o\u015bwietleniowych\"<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a> \"\u015awiat\u0142o i o\u015bwietlenie - Pomiar i prezentacja danych fotometrycznych lamp i opraw o\u015bwietleniowych - Cz\u0119\u015b\u0107 1: Pomiar i format pliku; Wersja niemiecka EN 13032-1:2004+A1:2012\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Pomiar utrzymania strumienia \u015bwietlnego \u017ar\u00f3de\u0142 \u015bwiat\u0142a LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-121<\/a> \"Fotometria i goniofotometria opraw o\u015bwietleniowych\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-70-1987-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-70 <\/a>\u00a0\u201cThe Measurement of Absolute Luminous Intensity Distribution\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-75<\/a>\u00a0 \"Typy goniofotometr\u00f3w i wsp\u00f3\u0142rz\u0119dne fotometryczne\"<\/p>\n<p><strong>Cechy:<\/strong><br \/>\n\u2022 The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop.<br \/>\n\u2022 The working principles are according to IESNA and CIE. The LSG-2000 completely meets the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESLM-79-LM-80-Chinese-Version-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">LM-80<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">LM-75<\/a>, GB, EN13032-1 and <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE121-1996<\/a> standardy.<br \/>\n\u2022 Special collimation device with laser cross line help you installaing the position of luminaires undertest conveniently and accurately.<\/p>\n<p><strong>Specyfikacje:<\/strong><br \/>\n\u2022 The mirror rotates around the luminaire under test with an angle of (\u03b3) \u00b1180\u00b0 (or 0-360\u00b0) and the luminaire rotates around itself with an angle of (C) \u00b1180\u00b0 (or 0-360\u00b0).<br \/>\n\u2022 The accuracy of angle: 0.05\u00b0, Resolution of angle: 0.001\u00b0<br \/>\n\u2022 Accuracy of\u00a0<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">fotodetektor<\/a>: Constant temperature\u00a0<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">fotodetektor<\/a>\u00a0DIN5032-6\/CIE pub1. No. 69 Class L<br \/>\n\u2022 LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux.<br \/>\n\u2022 Connect goniophotometer to PC via USB cable. English version software can run on Win7, Win8, Win10 Win11.<br \/>\n\u2022 LSG-2000 can be used together with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system \u201cGoniospectroradiometer (LSG-2000CCD)\u201d. Please download the brochure for LSG-2000CCD.<\/p>\n<table style=\"width: 94.1357%;\" border=\"1\" width=\"1144\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 19.2476%;\">Model LISUN<\/td>\n<td style=\"width: 17.3997%;\">LSG-2000B (Big Size)<\/td>\n<td style=\"width: 18.5855%;\">LSG-2000 (Standard Size)<\/td>\n<td style=\"width: 18.6096%;\">LSG-2000S (Small Size)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Non-Flood Lamp<\/td>\n<td style=\"width: 17.3997%;\">\u03a6 1600*800mm, 50kg<\/td>\n<td style=\"width: 18.5855%;\">\u03a6 1400*500mm, 40kg<\/td>\n<td style=\"width: 18.6096%;\">\u03a6 1000*460mm, 30kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Flood Lamp<\/td>\n<td style=\"width: 17.3997%;\">600*600mm, 50kg<\/td>\n<td style=\"width: 18.5855%;\">600*600mm, 40kg<\/td>\n<td style=\"width: 18.6096%;\">400*400mm, 30kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Power (W)<\/td>\n<td style=\"width: 17.3997%;\">600V\/10A, AC\/DC<\/td>\n<td style=\"width: 18.5855%;\">600V\/10A, AC\/DC<\/td>\n<td style=\"width: 18.6096%;\">600V\/10A, AC\/DC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The darkroom can be designed according to the customer\u2019s existing room size. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":410,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[91],"class_list":["post-2333","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-2000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2333"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2333\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/410"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2333"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2333"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}