{"id":2362,"date":"2025-06-19T19:35:01","date_gmt":"2025-06-19T11:35:01","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/automatic-safety-test-system\/"},"modified":"2025-07-01T17:42:53","modified_gmt":"2025-07-01T09:42:53","slug":"automatic-safety-test-system","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/automatic-safety-test-system\/","title":{"rendered":"Tester bezpiecze\u0144stwa IEC60598 dla linii produkt\u00f3w"},"content":{"rendered":"<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The LS9955\/LS9956<a href=\"https:\/\/www.lisungroup.com\/products\/electrical-safety-tester\/automatic-safety-test-system.html\" target=\"_blank\" rel=\"noopener\"> Automatic Safety Test System<\/a> (electrical safety analyzer) combines the following functions: Withstand Voltage Test (AC \/ DC), Insulation Resistance Test (IR), Leakage Current Test (LLC), Grounding Resistance Test (GR) and Power Test (LS9956 includes Power Test, LS9955 does not include Power Test).<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The equipment is mainly used for lighting fixtures, household appliances and motor tools safety test on the production line or in the R&amp;D laboratory.<\/span><\/span><\/span><\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-4706.1-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC\/EN 60335-1:2023\/GB 4706.1-2024 \u201cHousehold and similar electrical appliances \u2013 Safety \u2013 Part 1: General requirements\u201d<\/a><br \/>\nUL 60335:2022 \u201cStandard for Safety of Household and Similar Appliances, Part 1: General Requirements\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-7000.1-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60598:2024\/GB 7000-2023 \u201cLuminaires \u2013 Part 1: General requirements and tests\u201d<\/a><br \/>\nIEC 60950:2020 \u201cInformation technology equipment Safety \u2013Part 1: General requirements \u201c<br \/>\nIEC 62368-1:2023\/GB 4943-2022 \u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d<br \/>\nIEC 60601-1 3.1:2012\/ GB 9706.1-2020 \u201cMedical Electrical Equipment \u2013 Part 1: General Requirements For Basic Safety And Essential Performance\u201d<\/p>\n<p><strong>Specification:<\/strong><br \/>\n\u2022 Remote control device and can control by software (Optional)<br \/>\n\u2022 Display all setting parameters and testing results in the same big LCD screen<br \/>\n\u2022 PASS\/FAIL limit values can be set. <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">If the object fails the test, there will be a light\/sound alarm<\/span><\/span><\/span><br \/>\n\u2022 Test mode is programmable;\u00a0 50 groups settings are available, 8 test steps per group<br \/>\n\u2022 Quick discharge. Support 50Hz and 60Hz frequency; Electric safety wall detecting feature<br \/>\n\u2022 The LS9955 can test Withstand Voltage (AC\/DC), Insulation Resistance (IR), Leakage Current (LLC) and Ground Resistance (GR)<br \/>\n\u2022 The LS9956 can test Withstand Voltage (AC\/DC), Insulation Resistance (IR), Leakage Current (LLC), Ground Resistance (GR) and Power<\/p>\n<table style=\"width: 100.641%; height: 216px;\" border=\"1\" width=\"1113\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 46.5271%;\" colspan=\"3\"><strong>Withstand Voltage Test (AC\/DC)<\/strong><\/td>\n<td style=\"height: 24px; width: 42.9769%;\" colspan=\"3\"><strong>Insulation Resistance Test (IR)<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 15.4139%;\">Voltage Range<\/td>\n<td style=\"height: 24px; width: 15.6993%;\">Accuracy<\/td>\n<td style=\"height: 24px; width: 15.4139%;\">Current Range<\/td>\n<td style=\"height: 24px; width: 13.7964%;\">IR Range<\/td>\n<td style=\"height: 24px; width: 13.7012%;\">Accuracy<\/td>\n<td style=\"height: 24px; width: 15.4793%;\">Voltage Range<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 15.4139%;\">100~4000V<\/td>\n<td style=\"height: 24px; width: 15.6993%;\">\u00b1 (5%+3V)<\/td>\n<td style=\"height: 24px; width: 15.4139%;\">AC: 0.10~20.00mA<br \/>\nDC: 0.10~12.00mA<\/td>\n<td style=\"height: 24px; width: 13.7964%;\">1.00~2000M\u03a9<\/td>\n<td style=\"height: 24px; width: 13.7012%;\">5% + 0.5M\u03a9<\/td>\n<td style=\"height: 24px; width: 15.4793%;\">DC100~1000V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 46.5271%;\" colspan=\"3\"><strong>Leakage Current Test (LLC)<\/strong><\/td>\n<td style=\"height: 24px; width: 42.9769%;\" colspan=\"3\"><strong>Grounding Resistance Test (GR)<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 15.4139%;\">LLC Range<\/td>\n<td style=\"height: 24px; width: 15.6993%;\">Accuracy<\/td>\n<td style=\"height: 24px; width: 15.4139%;\">Voltage Range<\/td>\n<td style=\"height: 24px; width: 13.7964%;\">GR Range<\/td>\n<td style=\"height: 24px; width: 13.7012%;\">Accuracy<\/td>\n<td style=\"height: 24px; width: 15.4793%;\">Output Current<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 15.4139%;\">0.10~20mA<\/td>\n<td style=\"height: 24px; width: 15.6993%;\">\u00b1 (0.3%+5uA)<\/td>\n<td style=\"height: 24px; width: 15.4139%;\">AC10.0~300.0V<\/td>\n<td style=\"height: 24px; width: 13.7964%;\">0~600m\u03a9<\/td>\n<td style=\"height: 24px; width: 13.7012%;\">\u00b1 (5%+2m\u03a9)<\/td>\n<td style=\"height: 24px; width: 15.4793%;\">AC1.00~30.00A<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 89.504%;\" colspan=\"6\"><strong>Power Test<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 15.4139%;\">Voltage<\/td>\n<td style=\"height: 24px; width: 15.6993%;\">Current<\/td>\n<td style=\"height: 24px; width: 15.4139%;\">Power<\/td>\n<td style=\"height: 24px; width: 13.7964%;\">PF<\/td>\n<td style=\"height: 24px; width: 13.7012%;\">Accuracy<\/td>\n<td style=\"height: 24px; width: 15.4793%;\">Test Time<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 15.4139%;\">10~300V<\/td>\n<td style=\"height: 24px; width: 15.6993%;\">0.010~20.00A<\/td>\n<td style=\"height: 24px; width: 15.4139%;\">1.0~6000.0W<\/td>\n<td style=\"height: 24px; width: 13.7964%;\">0.2~1.0<\/td>\n<td style=\"height: 24px; width: 13.7012%;\">Class 0.5<\/td>\n<td style=\"height: 24px; width: 15.4793%;\">0~999.9s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/automatic-electrical-safety-system-and-the-notes-when-you-are-testing.html\" target=\"_blank\" rel=\"noopener\">What\u2019s the test method of Automatic Electrical Safety System?<\/a><\/strong><br \/>\nPls. note that the DC high voltage output is a negative voltage, and the ground is a positive. When testing capacitance, there is a charging process when voltage is applied to both ends of the capacitor. At this time, there is a charging current in the test circuit. When the current is greater than the set leakage current value, the withstand voltage tester will alarm to interrupt the test , it cannot be proceed. Therefore, when the safety tester is testing, the voltage should be increased slowly, and the charging current should be less than the set leakage current value until the test voltage is specified, and the test should be performed. It is not possible to use a fixed voltage, reset-start method for testing. In the AC circuit, it is equivalent to the resistance in the DC circuit. <a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/automatic-electrical-safety-system-and-the-notes-when-you-are-testing.html\" target=\"_blank\" rel=\"noopener\">[\u2026more\u2026]<\/a><\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-ls9956-automatic-safety-test-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN LS9956 Automatic Safety Test System \u2013 After-sales Frequently Asked Questions (FAQ).<\/a><\/span><br \/>\n<\/strong>LISUN LS9956 Automatic Safety Test System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The LS9955\/LS9956 Automatic Safety Test System (electrical safety analyzer) combines the following functions: Withstand Voltage Test (AC \/ DC), Insulation Resistance Test (IR), Leakage Current Test (LLC), Grounding Resistance Test (GR) and Power Test (LS9956 includes Power Test, LS9955 does not include Power Test). The equipment is mainly used for lighting fixtures, household appliances and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3461,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[119],"class_list":["post-2362","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls9955"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2362","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2362"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2362\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/3461"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2362"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2362"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2362"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}