{"id":2380,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/scientific-grade-ccd-spectroradiometer\/"},"modified":"2025-06-27T14:05:44","modified_gmt":"2025-06-27T06:05:44","slug":"scientific-grade-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/scientific-grade-ccd-spectroradiometer\/","title":{"rendered":"Spektroradiometr CCD klasy naukowej"},"content":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Renderowanie kolor\u00f3w bia\u0142ych \u017ar\u00f3de\u0142 \u015bwiat\u0142a LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"Pomiar strumienia \u015bwietlnego\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Metoda pomiaru i okre\u015blania w\u0142a\u015bciwo\u015bci oddawania barw przez \u017ar\u00f3d\u0142a \u015bwiat\u0142a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Pomiary optyczne i elektryczne p\u00f3\u0142przewodnikowych produkt\u00f3w o\u015bwietleniowych\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"Standardowy format pliku IESNA do elektronicznego przesy\u0142ania danych fotometrycznych i powi\u0105zanych informacji\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Pomiar utrzymania strumienia \u015bwietlnego \u017ar\u00f3de\u0142 \u015bwiat\u0142a LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Specyfikacje chromatyczno\u015bci p\u00f3\u0142przewodnikowych produkt\u00f3w o\u015bwietleniowych do lamp elektrycznych\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(UE) 2019\/2015<\/a> \"ROZPORZ\u0104DZENIE DELEGOWANE KOMISJI\"<\/p>\n<p><strong>Specyfikacja:<\/strong><br \/>\n\u2022 CCD detector: Hamamatsu TE-cooled (Temp: -10\u00b0C \u00b10.05\u00b0C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)<br \/>\n- Dok\u0142adno\u015b\u0107 spektralnej d\u0142ugo\u015bci fali: \u00b10,2 nm, Rozdzielczo\u015b\u0107: \u00b10,1 nm, Kroki skanowania pr\u00f3bki: \u00b10,1nm<br \/>\n- Dok\u0142adno\u015b\u0107 wsp\u00f3\u0142rz\u0119dnych chromatyczno\u015bci (\u0394x, \u0394y): \u00b10,0015 (przy standardowej lampie A)<br \/>\n- Skorelowana temperatura barwowa CCT: 1, 500K~100, 000K, dok\u0142adno\u015b\u0107 CCT: \u00b10,2%<br \/>\n- Zakres wska\u017anika oddawania barw: 0~100,0, Dok\u0142adno\u015b\u0107: \u00b1(0,3%rd\u00b10,3)<br \/>\n\u2022 Photometric linear: \u00b10.2%, Stray light: &lt;0.015%(600nm) and &lt;0.03% (435nm)<br \/>\n- Czas integracji: 0,1 ms-60 s<br \/>\n- Mo\u017ce mierzy\u0107 temperatur\u0119 wewn\u0105trz i na zewn\u0105trz sfery ca\u0142kuj\u0105cej<br \/>\n\u2022 Flux testing method: spectrum, photometric, spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Model LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CSWIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>D\u0142ugo\u015b\u0107 fali<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<td style=\"width: 20%;\">800-1700nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System - Cz\u0119sto zadawane pytania posprzeda\u017cowe (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System dzia\u0142a na rynku od ponad 10 lat, zesp\u00f3\u0142 serwisowy in\u017cynier\u00f3w LISUN podsumowa\u0142 ju\u017c wi\u0119kszo\u015b\u0107 pyta\u0144 i odpowiedzi posprzeda\u017cowych w powy\u017cszym linku. Prosimy o uwa\u017cne zapoznanie si\u0119 z jego tre\u015bci\u0105, aby w razie jakichkolwiek w\u0105tpliwo\u015bci podczas korzystania z przyrz\u0105d\u00f3w mo\u017cna by\u0142o samodzielnie rozwi\u0105za\u0107 wi\u0119kszo\u015b\u0107 problem\u00f3w. Firma LISUN b\u0119dzie nadal aktualizowa\u0107 te strony, a wi\u0119cej cz\u0119sto zadawanych pyta\u0144 mo\u017cna znale\u017a\u0107 w tym temacie.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[137],"class_list":["post-2380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9500c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2380"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/4774"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}