{"id":2419,"date":"2025-06-19T19:35:35","date_gmt":"2025-06-19T11:35:35","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ccd-spectroradiometer-integrating-sphere-compact-system\/"},"modified":"2025-07-01T16:59:01","modified_gmt":"2025-07-01T08:59:01","slug":"ccd-spectroradiometer-integrating-sphere-compact-system","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/ccd-spectroradiometer-integrating-sphere-compact-system\/","title":{"rendered":"LPCE-3 Wysokiej jako\u015bci system kuli integruj\u0105cej"},"content":{"rendered":"<p>LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires\u2019 photometric, colorimetric and electrical measurement. The measured data meets the requirements of <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a>,\u00a0 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">ROZPORZ\u0104DZENIE DELEGOWANE KOMISJI (UE) 2019\/2015<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-79-19<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/OPTICAL-ENGINEERING-49-3-033602-2010-COLOR-QUALITY-SCALE-CQS-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Optical-Engineering-49-3-033602<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> and GB standards.<\/p>\n<p><strong>Standard:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Pomiary optyczne i elektryczne p\u00f3\u0142przewodnikowych produkt\u00f3w o\u015bwietleniowych\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"Standardowy format pliku IESNA do elektronicznego przesy\u0142ania danych fotometrycznych i powi\u0105zanych informacji\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Renderowanie kolor\u00f3w bia\u0142ych \u017ar\u00f3de\u0142 \u015bwiat\u0142a LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"Pomiar strumienia \u015bwietlnego\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Metoda pomiaru i okre\u015blania w\u0142a\u015bciwo\u015bci oddawania barw przez \u017ar\u00f3d\u0142a \u015bwiat\u0142a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Specyfikacje chromatyczno\u015bci p\u00f3\u0142przewodnikowych produkt\u00f3w o\u015bwietleniowych do lamp elektrycznych\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(UE) 2019\/2015<\/a> \"ROZPORZ\u0104DZENIE DELEGOWANE KOMISJI\"<\/p>\n<p><strong>Configuration:\u00a0<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/products\/spectroradiometer\/ccd-spectroradiometer.html\" target=\"_blank\" rel=\"noopener\">Spektroradiometr CCD<\/a>\u00a0(LMS-7000),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/optical-fiber.html\" target=\"_self\" rel=\"noopener\">\u015awiat\u0142ow\u00f3d<\/a>\u00a0(CFO-1.5M),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-ac-dc-model.html\" target=\"_self\" rel=\"noopener\">Cyfrowy miernik mocy<\/a> (LS2012), <a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/dc-power-source-for-standard-lamp.html\" target=\"_blank\" rel=\"noopener\">\u0179r\u00f3d\u0142o zasilania pr\u0105dem sta\u0142ym<\/a>\u00a0(DC-S Series),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-supply.html\" target=\"_blank\" rel=\"noopener\">\u0179r\u00f3d\u0142o zasilania AC<\/a>\u00a0(LSP-500VAS),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_self\" rel=\"noopener\">Integruj\u0105ca sfera<\/a>\u00a0(IS-1.5MA-CASE and IS-0.3M), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/standard-light-source.html\" target=\"_blank\" rel=\"noopener\">Standardowe \u017ar\u00f3d\u0142o \u015bwiat\u0142a<\/a> (SLS-50W and SLS-10W)<\/p>\n<p><strong>Pomiar:<br \/>\n<\/strong>\u2022 Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI (Ra, R1 to R15), Spectrum Test, TM30 (Rf, Rg), CQS<br \/>\n\u2022 Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, PAR, PPF<br \/>\n\u2022 Electrical: Voltage, Current, Power, Power Factor, Harmonic (Optional)<\/p>\n<p><strong>Specyfikacja:<\/strong><br \/>\n\u2022 Spectral Range Wavelength: 350nm~950nm(LMS-7000VIS) (200~1050nm is optional)<br \/>\n\u2022 Spectral Wavelength Accuracy: \u00b10.5nm \u00a0Wavelength Reproducibility: \u00b10.5nm<br \/>\n- Kroki skanowania pr\u00f3bki: \u00b10,1 nm<br \/>\n\u2022 Accuracy of Chromaticity Coordinate (\u0394x, \u0394y): \u00b10.003 (under Standard A Lamp)<br \/>\n\u2022 Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: \u00b10.5%<br \/>\n\u2022 Color Rendering Index Range: 0~100.0, Accuracy: \u00b1 (0.3%rd\u00b10.3)<br \/>\n\u2022 Photometric linear: \u00b10.5%<br \/>\n\u2022 Stray light: &lt;0.015% (600nm) and &lt;0.03% (435nm)<br \/>\n- System zawiera dodatkowe urz\u0105dzenie \u015bwietlne, a oprogramowanie zawiera funkcj\u0119 korekcji wsp\u00f3\u0142czynnika absorpcji w\u0142asnej<br \/>\n- Po\u0142\u0105czenie z komputerem za pomoc\u0105 kabla USB. Oprogramowanie w wersji angielskiej mo\u017ce dzia\u0142a\u0107 w systemach Win7, Win8, Win10, Win11 (sterownik z certyfikatem Microsoft).<\/p>\n<h2><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-can-you-use-integrating-spheres-to-measure-the-quality-of-led-instruments.html\" target=\"_blank\" rel=\"noopener\">How do you use an integrating sphere to detect the quality of LED lighting products?<\/a><\/strong><\/h2>\n<p>An integrating sphere is frequently used to measure luminaire or light source for luminous flux, chromaticity coordinates, CCT, dominant wavelength, peak wavelength, etc. The traditional integrating sphere is the IS-*M, which LISUN has already stopped manufacturing in favor of the IS-*MA, which uses a molding method. It is your finest choice to take into consideration if your application calls for the measurement of a beam that is widely divergent.<\/p>\n<h2><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/integrating-sphere-spectroradiometer-for-photometry.html\" target=\"_blank\" rel=\"noopener\">Integrating Sphere &amp; Spectroradiometer for Photometry?<\/a><\/strong><\/h2>\n<p>Lumen is a unit of measurement for the total amount of visible light emitted by a light source. It is an important parameter in lighting design and evaluation, as it reflects the brightness and effectiveness of a lighting system. To accurately measure lumen output, a spectroradiometer system with an\u00a0integrating sphere\u00a0is commonly used. In this technical article, we will discuss how to test lumen by\u00a0integrating sphere\u00a0spectroradiometer system.<\/p>\n<div class=\"video\" data-url=\"https:\/\/www.youtube.com\/embed\/zse6_Nlsufo?autoplay=1\"><i class=\"video_play fa\"><\/i> <img fetchpriority=\"high\" decoding=\"async\" title=\"How to use the integrating sphere? | How do you clean an integrated sphere? - LISUN\" src=\"https:\/\/i.ytimg.com\/vi\/zse6_Nlsufo\/sddefault.jpg\" alt=\"wideo\" width=\"640\" height=\"480\" \/><\/div>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-3-ccd-spectroradiometer-integrating-sphere-compact-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-3 (LMS-7000) CCD Spectroradiometer Integrating Sphere Compact System \u2013 After-sales Frequently Asked Questions (FAQ)\u00a0<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-3 system were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires\u2019 photometric, colorimetric and electrical measurement. The measured data meets the requirements of CIE 177, CIE84,\u00a0 CIE-13.3, COMMISSION DELEGATED REGULATION (EU) 2019\/2015, IES LM-79-19, Optical-Engineering-49-3-033602, IESNA LM-63-2, ANSI-C78.377 and GB standards. Standard: LM-79-19 \u201cOptical and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[176],"class_list":["post-2419","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lpce-3"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2419","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2419"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2419\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/3435"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2419"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2419"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}