{"id":2451,"date":"2025-06-19T19:35:58","date_gmt":"2025-06-19T11:35:58","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-and-low-temperature-low-pressure-chamber\/"},"modified":"2025-06-27T14:20:40","modified_gmt":"2025-06-27T06:20:40","slug":"high-and-low-temperature-low-pressure-chamber","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/high-and-low-temperature-low-pressure-chamber\/","title":{"rendered":"High and Low Temperature &#038; Low Pressure Chamber"},"content":{"rendered":"<p>LAP-100A High and Low Temperature Low Pressure Chamber\u00a0 is mainly used in aviation, aerospace, information, electronics and other fields, to determine the instrumentation, electrical products, materials, parts, equipment in low pressure, high temperature, low temperature single or simultaneous action of the environmental adaptability and reliability test, and at the same time the test sample is turned on for electrical performance parameters measurement.<\/p>\n<p><strong>Standard:<br \/>\n<\/strong>IEC 60068-2-13 \u201cEnvironmental testing \u2013 Part 2-13: Tests \u2013 Test M: Low air pressure\u201d<br \/>\nIEC 60068-2-40 \u201cBasic environmental testing procedures \u2013 Part 2-40: Tests \u2013 Test Z\/AM: Combined cold\/low air pressure tests\u201d<br \/>\nIEC 60068-2-41 \u201cBasic environmental testing procedures \u2013 Part 2-41: Tests \u2013 Test Z\/BM: Combined dry heat\/low air pressure tests\u201d<br \/>\nASTM D 6653 \u201cStandard Test Methods for Determining the Effects of High Altitude on Packaging Systems by Vacuum Method\u201d<br \/>\nISO 2873 \u201cPackaging Complete, filled transport packages and unit loads Low pressure test\u201d<br \/>\nGB10590 \u201cSpecifications for high and low temperature\/low air pressure testing chambers\u201d<br \/>\nGB15091 \u201clow temperature low pressure test chamber requirements\u201d<br \/>\nGB11159 \u201cSpecification for low air pressure test chambers\u201d<br \/>\nGB\/T2423. 25-1992 \u201cBasic environmental testing procedures for electric and electronic products \u2013 Test Z\/AM: combined cold \/ low air pressure tests\u201d<br \/>\nGJB150. 2-86 \u201cEnvironmental test methods for military equipments\u201d<\/p>\n<p><strong>Specyfikacja:<\/strong><\/p>\n<table style=\"width: 100.17%; height: 1056px;\" width=\"661\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 24px;\" colspan=\"2\" width=\"132\"><strong>Model LISUN<\/strong><\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"80\"><strong>LAP-100*<\/strong><\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"80\"><strong>LAP-250*<\/strong><\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"80\"><strong>LAP-500*<\/strong><\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"96\"><strong>LAP-010*<\/strong><\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"97\"><strong>LAP-015*<\/strong><\/td>\n<td style=\"vertical-align: middle; width: 13.0395%; height: 24px;\" width=\"96\"><strong>LAP-020*<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 24px;\" colspan=\"2\" width=\"132\">Working Room (cm)<\/td>\n<td style=\"height: 24px; vertical-align: middle; width: 12.9477%;\" width=\"105\">41*55*45<\/td>\n<td style=\"height: 24px; vertical-align: middle; width: 12.9477%;\" width=\"105\">\u00a050*60*75<\/td>\n<td style=\"height: 24px; vertical-align: middle; width: 12.9477%;\" width=\"105\">\u00a070*80*90<\/td>\n<td style=\"height: 24px; vertical-align: middle; width: 12.9477%;\" width=\"105\">100*100*100<\/td>\n<td style=\"height: 24px; vertical-align: middle; width: 12.9477%;\" width=\"105\">100*100*150<\/td>\n<td style=\"height: 24px; vertical-align: middle; width: 13.0395%;\" width=\"105\">100*100*200<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 24px;\" colspan=\"2\" width=\"132\">Moc robocza<\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"80\">5.5 (KW)<\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"80\">8.0 (KW)<\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"80\">9.0 (KW)<\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"96\">11.0 (KW)<\/td>\n<td style=\"vertical-align: middle; width: 12.9477%; height: 24px;\" width=\"97\">17.0 (KW)<\/td>\n<td style=\"vertical-align: middle; width: 13.0395%; height: 24px;\" width=\"96\">22.0 (KW)<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.3765%; height: 336px;\" rowspan=\"9\" width=\"66\">Performance Index<\/td>\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Zakres temperatur<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">A: -20\u2103~150\u2103 B: -40\u2103~150\u2103 C: -60\u2103~150\u2103 D: -70\u2103~150\u2103<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Temperature Fluctuations<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">\u00b10.5\u2103 (Normal Pressure, No-Load)<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">R\u00f3wnomierno\u015b\u0107 temperatury<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">\u00b12\u2103 (Normal Pressure, No-Load)<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Odchylenie temperatury<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">\u00b13\u2103 (Normal Pressure, No-Load)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 24px;\" width=\"66\">Szybko\u015b\u0107 ogrzewania<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">1.0~3.0\u2103\/ min (No-Load)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 24px;\" width=\"66\">Szybko\u015b\u0107 ch\u0142odzenia<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">0.7~1.0\u2103\/ min (No-Load)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 24px;\" width=\"66\">Zakres ci\u015bnienia<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">Normal Pressure~0.5kPa<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Pressure Deviation<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Normal Pressure~40Kp: \u00b11.8Kpa; 40Kp\uff5e4Kpa: \u00b14.5\uff05; 4Kp\uff5e0.5KPa: \u00b10.1Kpa<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 24px;\" width=\"66\">Buck Time<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">\u226460min (Normal Pressure\uff5e0.5kPa)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 10.3765%; height: 288px;\" rowspan=\"7\" width=\"66\">System sterowania<\/td>\n<td style=\"vertical-align: middle; width: 10.4683%; height: 24px;\" width=\"66\">Controller<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">Imported Color LCD Touch Screen<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Accuracy Range<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Accuracy of temperature: temperature 0.1\u2103, Indication Accuracy: temperature 0.1\u2103<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Czujnik temperatury<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Platinum Resistance PT100\u03a9\/MV<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Pressure Sensor<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Electronic Pressure Transmitter<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">System ogrzewania<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Fully Independent System, Electrically Heated Nichrome Heater<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 24px;\" width=\"66\">Uk\u0142ad ch\u0142odzenia<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">France \u201cTECUMSEH\u201d Fully Enclosed Air-cooled Single-stage \/ Refrigeration Compressor Cascade Mode<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Circulatory System<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Temperature Resistance and Low-noise Air-conditioning Motors Multi-vane Centrifugal Wind Wheel<\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"vertical-align: middle; width: 10.3765%; height: 240px;\" rowspan=\"4\" width=\"66\">Materials of Chamber<\/td>\n<td style=\"vertical-align: middle; width: 10.4683%; height: 72px;\" width=\"66\">Outside materials of Chamber<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 72px;\" colspan=\"6\" width=\"529\">Quality Carbon Steel. Phosphate Electrostatic Spray Treatment \/ SUS304 Stainless Steel Matte Lines Hairline Treatment<\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 72px;\" width=\"66\">Inside materials of Chamber<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 72px;\" colspan=\"6\" width=\"529\">SUS304 Quality Stainless Steel Mirror Light Board<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Insulation Material<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Polyurethane Rigid Foam \/ Fine Glass Fiber Cotton<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 10.4683%; height: 48px;\" width=\"66\">Door Insulation<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Double Resistant to High Temperature Aging Silicone Rubber Door Seal<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 48px;\" colspan=\"2\" width=\"132\">Security Protection<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 48px;\" colspan=\"6\" width=\"529\">Leakage, Short Circuit, Over Temperature, Motor Overheating, Over-Pressure Compressor, Overload, Over-Current Protection<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 24px;\" colspan=\"2\" width=\"132\">Time setting Function<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">0.1~999.9 (H\u3001M\u3001S) Adjustable<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 24px;\" colspan=\"2\" width=\"132\">Input Power<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">3Phase\/5Wires, AC380V\/50Hz (60Hz is option)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"vertical-align: middle; width: 20.8448%; height: 24px;\" colspan=\"2\" width=\"132\">Ambient Temperature<\/td>\n<td style=\"vertical-align: middle; width: 77.778%; height: 24px;\" colspan=\"6\" width=\"529\">5\u2103~\uff0b30\u2103 \u226485\uff05R.H<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #ff0000;\">Ordering Note: The * in LAP-100* can choose four temperature ranges A\/B\/C\/D. For example: LISUN model LAP-100B where B represents the temperature range of -40\u2103~150\u2103. Special working room sizes and temperature ranges can be customized according to customer\u2019s requirements.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>LAP-100A High and Low Temperature Low Pressure Chamber\u00a0 is mainly used in aviation, aerospace, information, electronics and other fields, to determine the instrumentation, electrical products, materials, parts, equipment in low pressure, high temperature, low temperature single or simultaneous action of the environmental adaptability and reliability test, and at the same time the test sample is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3405,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[205],"class_list":["post-2451","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lap-100a"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2451"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2451\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/3405"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2451"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2451"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}