{"id":2608,"date":"2025-06-19T19:37:37","date_gmt":"2025-06-19T11:37:37","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/test-probe-d-with-cable-of-iec-61032-figure-4\/"},"modified":"2025-06-25T17:08:38","modified_gmt":"2025-06-25T09:08:38","slug":"test-probe-d-with-cable-of-iec-61032-figure-4","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/test-probe-d-with-cable-of-iec-61032-figure-4\/","title":{"rendered":"Test Probe D with Cable of IEC 61032 Figure 4"},"content":{"rendered":"<p>IEC61032:1997 Sonda testowa D IP4X Pr\u0119t testowy 1,0 mm<\/p>\n<p><strong>Podstawowe wprowadzenie:<\/strong><br \/>\n1. Zgodnie z: GB\/T4208-2008 \/ IEC61032:1997 \/ IEC60529:2001 \/ IEC60065 \/ IEC60598 i UL<br \/>\n2. Sonda testowa IP4X D (Sonda testowa D) jest narz\u0119dziem niezb\u0119dnym do przeprowadzania test\u00f3w ochrony przeciwpora\u017ceniowej urz\u0105dze\u0144 gospodarstwa domowego i podobnych urz\u0105dze\u0144 elektrycznych.<\/p>\n<p><strong>Technical parameter:<\/strong><br \/>\n1. D\u0142ugo\u015b\u0107 pr\u0119ta testowego: 100 mm<br \/>\n2. \u015arednica pr\u0119ta testowego: 1,0 mm<br \/>\n3. \u015arednica przegrody okr\u0105g\u0142ej: 35 mm<br \/>\n4. \u015arednica uchwytu: 10 mm<br \/>\n5. D\u0142ugo\u015b\u0107 uchwytu: 100 mm<br \/>\n6. Zgodnie z norm\u0105 IEC61032 rysunek 4 (sonda testowa D).<\/p>\n<p><strong>Zastosowanie:<\/strong><br \/>\n1. Test standardowy oznacza, \u017ce cz\u0119\u015b\u0107 \u0142\u0105cz\u0105ca nie mo\u017ce dotyka\u0107 cz\u0119\u015bci pod napi\u0119ciem lub znajdowa\u0107 si\u0119 w pobli\u017cu cz\u0119\u015bci niebezpiecznych. Nie mo\u017cna r\u00f3wnie\u017c wej\u015b\u0107 do okr\u0105g\u0142ej przegrody o \u015brednicy 35 mm.<br \/>\n2. W ramach wymaga\u0144 testowych dotycz\u0105cych zapobiegania dost\u0119powi do cz\u0119\u015bci niebezpiecznych, sonda testowa D musi mie\u0107 si\u0142\u0119 nacisku 1\u00b10,1N.<\/p>\n<p><strong>Zamiar:<\/strong><br \/>\nSonda ta s\u0142u\u017cy do weryfikacji podstawowej ochrony przed dost\u0119pem do cz\u0119\u015bci niebezpiecznych. S\u0142u\u017cy r\u00f3wnie\u017c do weryfikacji ochrony przed dost\u0119pem za pomoc\u0105 narz\u0119dzia.<\/p>\n<p><strong>Notatka:<\/strong><br \/>\nW przypadku produkt\u00f3w bez si\u0142y nacisku nale\u017cy u\u017cywa\u0107 miernika si\u0142y pchania-ci\u0105gni\u0119cia.<\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 61032 \u201cOchrona os\u00f3b i urz\u0105dze\u0144 za pomoc\u0105 obud\u00f3w \u2013 Sondy do weryfikacji\u201d<br \/>\nIEC 60529 \u201cStopnie ochrony zapewniane przez obudowy (kod IP)\u201d<br \/>\nIEC 60065 \u201cAparatura elektroniczna akustyczna, wizyjna i podobna \u2013 Wymagania bezpiecze\u0144stwa\u201d<br \/>\nIEC 60598-1 \u201cOprawy o\u015bwietleniowe \u2013 Cz\u0119\u015b\u0107 1: Wymagania og\u00f3lne i badania\u201d<br \/>\nUL, GB\/T 4208<\/p>\n<div id=\"attachment_12290\" class=\"wp-caption aligncenter\" style=\"width: 708px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-12290 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/SMT-1204C_YK.png\" sizes=\"(max-width: 698px) 100vw, 698px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/SMT-1204C_YK.png 698w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/SMT-1204C_YK-400x113.png 400w\" alt=\"\" width=\"698\" height=\"198\" aria-describedby=\"caption-attachment-12290\" title=\"\"><\/p>\n<p id=\"caption-attachment-12290\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Test Probe D with Cable of IEC61032 Figure 4<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>IEC61032:1997 Test Probe D IP4X Test Rod 1.0 mm Basic Introduction: 1. According to: GB\/T4208-2008 \/ IEC61032:1997 \/ IEC60529:2001 \/ IEC60065 \/ IEC60598 and UL 2. IP4X Test Probe D ( Test Probe D) is the necessary tool to proceed protecting electric shock test of household and similar electrical appliances. Technical parameter: 1. Test rod [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3614,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[352],"class_list":["post-2608","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-smt-1204c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2608"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2608\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/3614"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2608"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2608"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}