{"id":2859,"date":"2025-06-19T19:41:24","date_gmt":"2025-06-19T11:41:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60884-1-clause-10-2-and-24-6-figure-6-compression-test-device\/"},"modified":"2025-06-25T13:20:12","modified_gmt":"2025-06-25T05:20:12","slug":"iec-60884-1-clause-10-2-and-24-6-figure-6-compression-test-device","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pl\/produkty\/iec-60884-1-clause-10-2-and-24-6-figure-6-compression-test-device\/","title":{"rendered":"IEC 60884-1 Clause 10.2 and 24.6 Figure 6 Compression Test Device"},"content":{"rendered":"<p>Compression Test Device fully meet the IEC 60884-1:2022 Clause 10.2 and 24.6 Figure 6, EN 50075:1990 Clause 13.1 and Figure 7 (GB\/T 2099.1-2021 clause 10.1 and 24.6 and Figure 8) . <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It is suitable for testing the pressure resistance of plugs, using weights to apply force to check whether the mechanical strength of the plug meets the standard requirements.<\/span><\/span><\/span><\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d Clause 10.2 and 24.6 Figure 6<br \/>\nEN 50075 \u201cFlat non-rewirable two-pole plugs, 2,5 A 250 V, with cord, for the connection of class II-equipment for household and similar purposes\u201d Clause 13.1 and Figure 7<\/p>\n<p><strong>Specyfikacja:<\/strong><\/p>\n<table style=\"width: 99.6533%; height: 333px;\" width=\"578\">\n<tbody>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"160\">Parametr<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">Specyfikacja<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"160\">Base<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">Alumina plate<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"160\">Main weight:<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">150N<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"160\">Additional weight<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">150N<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 111px;\" rowspan=\"3\" width=\"160\">Loading weight<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">IEC 60884-1 Clause 10.2\uff0835\u00b12\u00b0C\uff09\uff1a150N (GB\/T 2099.1 Clause 10.1\uff0840\u00b12\u00b0C\uff09)<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">IEC 60884-1 Clause 24.6\uff0823\u00b12\u00b0C\uff09\uff1a300N (GB\/T 2099.1 Clause 24.6\uff0823\u00b12\u00b0C\uff09)<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">Notes: It should work together with LISUN<a href=\"https:\/\/www.lisungroup.com\/products\/environmental-test-chamber\/high-and-low-temperature-humidity-chamber.html\" target=\"_blank\" rel=\"noopener\"> GW-225 high temperature chamber<\/a><\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"160\">Up and down<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">Thread lifting<\/td>\n<\/tr>\n<tr style=\"height: 37px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"160\">Steel base<\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 37px;\" width=\"418\">Thickness&gt;5mm\uff0cWidth&gt;18mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_14529\" class=\"wp-caption aligncenter\" style=\"width: 1217px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14529 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/Y186LTIRZYUDDLMO5.jpg\" sizes=\"(max-width: 1207px) 100vw, 1207px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/Y186LTIRZYUDDLMO5.jpg 1207w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/Y186LTIRZYUDDLMO5-400x210.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/Y186LTIRZYUDDLMO5-768x403.jpg 768w\" alt=\"\" width=\"1207\" height=\"634\" aria-describedby=\"caption-attachment-14529\" title=\"\"><\/p>\n<p id=\"caption-attachment-14529\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Figure 6<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Compression Test Device fully meet the IEC 60884-1:2022 Clause 10.2 and 24.6 Figure 6, EN 50075:1990 Clause 13.1 and Figure 7 (GB\/T 2099.1-2021 clause 10.1 and 24.6 and Figure 8) . It is suitable for testing the pressure resistance of plugs, using weights to apply force to check whether the mechanical strength of the plug [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3465,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[553],"class_list":["post-2859","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-b08"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2859","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/comments?post=2859"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/posts\/2859\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media\/3465"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/media?parent=2859"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/categories?post=2859"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pl\/wp-json\/wp\/v2\/tags?post=2859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}