{"id":2328,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/portable-ccd-spectroradiometer-2\/"},"modified":"2025-07-03T14:51:11","modified_gmt":"2025-07-03T06:51:11","slug":"espectrorradiometro-portatil-ccd-2","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pt\/produtos\/espectrorradiometro-portatil-ccd-2\/","title":{"rendered":"Espectrorradi\u00f3metro de m\u00e3o"},"content":{"rendered":"<p>O color\u00edmetro port\u00e1til CCD LED Spectroradiometer tem as seguintes vers\u00f5es que podem medir diferentes par\u00e2metros:<strong><br \/>\n<\/strong><\/p>\n<table style=\"width: 100.373%; height: 792px;\" width=\"709\">\n<tbody>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">Modelo LISUN<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Fun\u00e7\u00e3o<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">Gama de ondas<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 151px;\" width=\"111\">LMS-6000<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 151px;\" width=\"497\">Ilumin\u00e2ncia, E(Fc), Ee(W\/m2), Tc (K), Duv Correlated Color Temperature (CCT), Coordenadas de Cromaticidade, CRI, TM-30 (Rf, Rg), Pureza, Comprimento de Onda de Pico, Comprimento de Onda Dominante, Meia Largura de Banda, Comprimento de Onda Central, Comprimento de Onda Centr\u00f3ide, Diferen\u00e7a Total de Cor, Diferen\u00e7a de Brilho, Grau Vermelho-Verde, Grau Amarelo-Azul, Diferen\u00e7a CCT, Diagrama SDCM, Diagrama de Espectro. Clique aqui para ver o <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000-Test-Report.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 151px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000C<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Par\u00e2metro LMS-6000 sem software de PC e TM-30 (Rf, Rg)<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 91px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 91px;\" width=\"111\">LMS-6000UV<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 91px;\" width=\"497\">Irradi\u00e2ncia radiante total UV-A, UV-B, UV-C e UV (0,1-500.000\u03bcW\/cm\u00b2 \u00b10,01\u03bcW\/cm\u00b2), irradi\u00e2ncia de perigo UV, espetro UV, comprimento de onda dominante, sinal de pico, comprimento de onda inicial, comprimento de onda final. Clique aqui para ver o <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lms-6000uv-test-report.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000UV<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 91px;\" width=\"101\">200-400nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000F<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Par\u00e2metros do LMS-6000+Teste de cintila\u00e7\u00e3o. Por favor, clique aqui para ver o <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000F.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000F<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 151px;\" width=\"111\">LMS-6000L<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 151px;\" width=\"497\">Brightness (0.1-500,000cd\/m\u00b2\u00b10.1cd\/m\u00b2), fL, Tc (K), Temperatura de Cor Correlacionada Duv (CCT), Coordenadas de Cromaticidade, CRI, TM-30 (Rf, Rg), Pureza, Comprimento de Onda de Pico, Comprimento de Onda Dominante, Meia Largura de Banda, Comprimento de Onda Central, Comprimento de Onda Centr\u00f3ide, Diferen\u00e7a Total de Cor, Diferen\u00e7a de Brilho, Grau Vermelho-Verde, Grau Amarelo-Azul, Diferen\u00e7a CCT, Diagrama SDCM, Diagrama de Espectro. Por favor, clique aqui para ver o <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000L.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000L<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 151px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 61px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 61px;\" width=\"111\">LMS-6000B<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 61px;\" width=\"497\">Par\u00e2metros LMS-6000+Irradi\u00e2ncia ponderada do risco de luz azul de acordo com GB\/T20145, CIE S009\/E:2002<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 61px;\" width=\"101\">350-800 nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000BF<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">LMS-6000B Par\u00e2metros+Teste de cintila\u00e7\u00e3o. Por favor, clique aqui para ver o <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000BF.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000BF<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">350-800 nm<\/td>\n<\/tr>\n<tr style=\"height: 91px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 91px;\" width=\"111\">LMS-6000P<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 91px;\" width=\"497\">Par\u00e2metros do LMS-6000+PAR, PPFD (0,1-500.000umol\/m\u00b2.s \u00b10,01umol\/m\u00b2.s) , YPFD, irradi\u00e2ncia azul-p\u00farpura Eb, irradi\u00e2ncia amarelo-verde Ey, irradi\u00e2ncia vermelho-laranja Er, r\u00e1cio de radia\u00e7\u00e3o vermelha e azul Erb_Ratio. Clique aqui para ver a <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000P.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000P<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 91px;\" width=\"101\">350-850nm<\/td>\n<\/tr>\n<tr style=\"height: 61px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 61px;\" width=\"111\">LMS-6000S<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 61px;\" width=\"497\">Par\u00e2metros LMS-6000P+Irradi\u00e2ncia ponderada do risco de luz azul de acordo com GB\/T20145, CIE S009\/E:2002<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 61px;\" width=\"101\">350-950nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000SF<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Fun\u00e7\u00f5es completas: Par\u00e2metros LMS-6000S + Teste de cintila\u00e7\u00e3o. Por favor, clique aqui para ver o <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000SF.pdf\" target=\"_blank\" rel=\"noopener\">Relat\u00f3rio de teste do LMS-6000SF<\/a>.<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">350-950nm<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"vertical-align: middle; width: 14.7771%; height: 31px;\" width=\"111\">LMS-6000I<\/td>\n<td style=\"vertical-align: middle; width: 71.4649%; height: 31px;\" width=\"497\">Controlo de entradas e sa\u00eddas via RS485<\/td>\n<td style=\"vertical-align: middle; width: 12.4841%; height: 31px;\" width=\"101\">380-780nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Padr\u00e3o<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \u201cRenderiza\u00e7\u00e3o de cores de fontes de luz LED brancas\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \u201cM\u00e9todo de Medi\u00e7\u00e3o e Especifica\u00e7\u00e3o de Propriedades de Reprodu\u00e7\u00e3o de Cor de Fontes de Luz\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/OPTICAL-ENGINEERING-49-3-033602-2010-COLOR-QUALITY-SCALE-CQS-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Engenharia \u00d3ptica-49-3-033602<\/a> \" Escala de qualidade da cor\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEEE-2015-STANDARDS-1789-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEEE<\/a>. \"Pr\u00e1ticas recomendadas para a modula\u00e7\u00e3o da corrente em LEDs de alto brilho para atenuar os riscos para a sa\u00fade dos telespectadores\"<\/p>\n<p><strong>Especifica\u00e7\u00f5es do Medidor de Croma:<\/strong><br \/>\n- Resolu\u00e7\u00e3o espetral: \u00b10,2nm, Reprodutibilidade: \u00b10,5nm<br \/>\n- Precis\u00e3o da coordenada de cromaticidade (\u0394x, \u0394y): \u00b10.005<br \/>\n- Temperatura de cor correlacionada CCT: 1, 500K ~ 100, 000K (\u00b10.6%)<br \/>\n- Gama de ilumina\u00e7\u00e3o: 0,1~500.000lx (\u00b10,1lx)<br \/>\n- Ecr\u00e3 LCD: Ecr\u00e3 t\u00e1til capacitivo IPS de 5 polegadas de alta defini\u00e7\u00e3o e resolu\u00e7\u00e3o at\u00e9 480*854<br \/>\n- Com bateria de i\u00f5es de l\u00edtio recarreg\u00e1vel de 4000mAh que pode funcionar continuamente durante 20 horas<br \/>\n- Dimens\u00f5es: 135mm*80mm*23mm<br \/>\n- Capacidade de armazenamento<span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">8GB, pode armazenar 5000 a 100.000 relat\u00f3rios de testes<\/span><\/span><\/span><br \/>\n- Ligar ao PC atrav\u00e9s de um cabo USB. O software da vers\u00e3o inglesa pode ser executado em Win7, Win8, Win10, Win11<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-3689 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1.jpg\" sizes=\"(max-width: 2880px) 100vw, 2880px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1.jpg 2880w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-400x119.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-768x228.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LMS-6000_FT3-1-1920x569.jpg 1920w\" alt=\"Relat\u00f3rio de teste do color\u00edmetro LED port\u00e1til LMS-6000 com espectrorradi\u00f3metro CCD\" width=\"2880\" height=\"854\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-new-version-lms-6000-portable-ccd-spectroradiometer-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LMS-6000 Espectrorradi\u00f4metro CCD port\u00e1til - Perguntas frequentes p\u00f3s-venda (FAQ)<\/span><\/a><br \/>\n<\/strong>LISUN LMS-6000 Espectrorradi\u00f4metro CCD port\u00e1til estavam no mercado h\u00e1 mais de 10 anos, a equipe de servi\u00e7o dos engenheiros da LISUN j\u00e1 resume a maioria das perguntas e respostas p\u00f3s-venda no link acima. Por favor, leia-o com aten\u00e7\u00e3o, voc\u00ea pode resolver a maioria dos problemas sozinho se tiver algumas perguntas ao usar os instrumentos. LISUN continuar\u00e1 a atualizar essas p\u00e1ginas e mais perguntas frequentes podem ser encontradas neste link de t\u00f3pico.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters: LISUN Model Function Wave Range LMS-6000 illuminance, E(Fc), Ee(W\/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, TM-30 (Rf, Rg), Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3419,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[42],"class_list":["post-2328","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-6000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/comments?post=2328"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2328\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media\/3419"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media?parent=2328"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/categories?post=2328"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/tags?post=2328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}