{"id":2380,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/scientific-grade-ccd-spectroradiometer\/"},"modified":"2025-06-27T14:05:44","modified_gmt":"2025-06-27T06:05:44","slug":"scientific-grade-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pt\/produtos\/scientific-grade-ccd-spectroradiometer\/","title":{"rendered":"Espectrorradi\u00f4metro CCD de n\u00edvel cient\u00edfico"},"content":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.<\/p>\n<p><strong>Padr\u00e3o<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \u201cRenderiza\u00e7\u00e3o de cores de fontes de luz LED brancas\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \u201cA medi\u00e7\u00e3o do fluxo luminoso\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \u201cM\u00e9todo de Medi\u00e7\u00e3o e Especifica\u00e7\u00e3o de Propriedades de Reprodu\u00e7\u00e3o de Cor de Fontes de Luz\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \u201cMedidas \u00d3pticas e El\u00e9tricas de Produtos de Ilumina\u00e7\u00e3o de Estado S\u00f3lido\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \u201cFormato de arquivo padr\u00e3o IESNA para transfer\u00eancia eletr\u00f4nica de dados fotom\u00e9tricos e informa\u00e7\u00f5es relacionadas\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \u201cMedindo a manuten\u00e7\u00e3o de l\u00famens de fontes de luz LED\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \u201cEspecifica\u00e7\u00f5es para a Cromaticidade de Produtos de Ilumina\u00e7\u00e3o de Estado S\u00f3lido para L\u00e2mpadas El\u00e9tricas\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(UE) 2019\/2015<\/a> \u201cREGULAMENTO DELEGADO DA COMISS\u00c3O\u201d<\/p>\n<p><strong>Especifica\u00e7\u00e3o:<\/strong><br \/>\n\u2022 CCD detector: Hamamatsu TE-cooled (Temp: -10\u00b0C \u00b10.05\u00b0C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)<br \/>\n\u2022 Precis\u00e3o do comprimento de onda espectral: \u00b10,2 nm, Resolu\u00e7\u00e3o: \u00b10,1 nm, Etapas de varredura da amostra: \u00b10,1 nm<br \/>\n\u2022 Precis\u00e3o da coordenada de cromaticidade (\u0394x, \u0394y): \u00b10,0015 (sob l\u00e2mpada padr\u00e3o A)<br \/>\n\u2022 Temperatura de cor correlacionada CCT: 1.500K~100.000K, precis\u00e3o CCT: \u00b10,2%<br \/>\n\u2022 Faixa de \u00edndice de renderiza\u00e7\u00e3o de cor: 0~100,0, Precis\u00e3o: \u00b1(0,3%rd\u00b10,3)<br \/>\n\u2022 Photometric linear: \u00b10.2%, Stray light: &lt;0.015%(600nm) and &lt;0.03% (435nm)<br \/>\n\u2022 Tempo de integra\u00e7\u00e3o: 0,1 ms-60 s<br \/>\n\u2022 Pode medir as temperaturas dentro e fora da esfera de integra\u00e7\u00e3o<br \/>\n\u2022 Flux testing method: spectrum, photometric, spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Modelo LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CSWIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Comprimento de onda<\/strong><\/td>\n<td style=\"width: 20%;\">350-800 nm<\/td>\n<td style=\"width: 20%;\">200-800 nm<\/td>\n<td style=\"width: 20%;\">350-1050 nm<\/td>\n<td style=\"width: 20%;\">800-1700nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">Sistema de esfera integradora de espectrorradi\u00f4metro de alta precis\u00e3o LISUN LPCE-2 (LMS-9500C) \u2013 Perguntas frequentes de p\u00f3s-venda (FAQ).<\/span><\/a><br \/>\n<\/strong>O Sistema Integrador de Esferas Espectrorradi\u00f4metro de Alta Precis\u00e3o LISUN LPCE-2 (LMS-9500C) est\u00e1 no mercado h\u00e1 mais de 10 anos. A equipe de engenharia da LISUN j\u00e1 resumiu a maioria das perguntas e respostas de p\u00f3s-venda no link acima. Leia com aten\u00e7\u00e3o, pois voc\u00ea pode resolver a maioria dos problemas sozinho, caso tenha alguma d\u00favida durante o uso do instrumento. A LISUN continuar\u00e1 atualizando estas p\u00e1ginas e mais perguntas frequentes podem ser encontradas neste link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[137],"class_list":["post-2380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9500c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/comments?post=2380"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media\/4774"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media?parent=2380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/categories?post=2380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/tags?post=2380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}