{"id":2400,"date":"2025-06-19T19:35:24","date_gmt":"2025-06-19T11:35:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/benchtop-spectrophotometer-reflectance-and-transmittance\/"},"modified":"2025-07-03T14:40:37","modified_gmt":"2025-07-03T06:40:37","slug":"benchtop-spectrophotometer-reflectance-and-transmittance","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pt\/produtos\/benchtop-spectrophotometer-reflectance-and-transmittance\/","title":{"rendered":"Desktop spectrophotometer"},"content":{"rendered":"<p>DSCD-950P Benchtop Spectrophotometer is an intelligent, convenient and high precise spectrophotometer. It adopts 7 inches touch screen, full-spectrum capability, and an Android operating system. Illumination modes include reflection D\/8\u00b0 and transmission D\/0\u00b0 (with UV inclusion\/exclusion measurements). It offers accurate and stable color measurements, a large storage capacity, and robust expansion capabilities on the PC end, making it suitable for laboratory color analysis and communication.<\/p>\n<p><strong>Introduction:<\/strong><br \/>\n- <strong>Adopts reflectance D\/8\u00b0 and transmittance D\/0\u00b0 geometry to measure both opaque and transparent materials.<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-8709 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220927145011.png\" sizes=\"(max-width: 535px) 100vw, 535px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220927145011.png 535w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220927145011-400x123.png 400w\" alt=\"\" width=\"535\" height=\"165\" title=\"\"><\/p>\n<p>- <strong>Dual Optical PathsSpectrum Analysis Technology<\/strong><br \/>\n<strong>This technology can simultaneous access to both measurement and instrument internal environmental reference data to ensure instrument accuracy and long-term stability.<\/strong><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-8738 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220928143056.png\" sizes=\"(max-width: 404px) 100vw, 404px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220928143056.png 404w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220928143056-400x214.png 400w\" alt=\"\" width=\"404\" height=\"216\" title=\"\"><\/p>\n<p>- <strong>Compatible with SCI\/SCE measurement, Support SCI+SCE Measurement<\/strong><br \/>\n<strong>Instrument adopts D\/8 geometry which is highly recommends by CIE (International Commission on Illumination) to meet color measurement of different industries.It supports both SCI (specula component included) and SCE (specular component excluded) mode for better detect of color change.Fast SCI+SCE measurement, test time only need less than 4s.<\/strong><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-8710 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-1.png\" sizes=\"(max-width: 526px) 100vw, 526px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-1.png 526w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-1-400x139.png 400w\" alt=\"\" width=\"526\" height=\"183\" title=\"\"><\/p>\n<p>- <strong>Rotatable Touch Screen with Android Operate System<\/strong><br \/>\n<strong>Screen position and direction can be adjusted according to the instrument test methods.<\/strong><\/p>\n<div id=\"attachment_14962\" class=\"wp-caption aligncenter\" style=\"width: 215px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14962\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/B3XB_SXRA7FP3FHHW_L.png\" sizes=\"(max-width: 205px) 100vw, 205px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/B3XB_SXRA7FP3FHHW_L.png 205w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/B3XB_SXRA7FP3FHHW_L-100x100.png 100w\" alt=\"\" width=\"205\" height=\"205\" aria-describedby=\"caption-attachment-14962\" title=\"\"><\/p>\n<p id=\"caption-attachment-14962\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Android Operate System<\/span><\/p>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8711 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-1.png\" alt=\"\" width=\"385\" height=\"257\" title=\"\"><\/p>\n<p>-<strong> Open Transmittance Measurement Area, no limit on sample size<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-8712 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-1-400x141.png\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-1-400x141.png 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-1.png 538w\" alt=\"\" width=\"400\" height=\"141\" title=\"\"><\/p>\n<p><strong>\u2022 Different Kinds of Accessories for simple measurement<\/strong><br \/>\n<strong>It contains 15 kinds of standard and 12 kinds of optional accessories to measure different kinds of materials<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-8713 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-1-400x144.png\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-1-400x144.png 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-1.png 485w\" alt=\"\" width=\"400\" height=\"144\" title=\"\"><\/p>\n<p><strong>\u2022 Accessory Drawer to Protect and Store Accessories<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8714 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-2.png\" alt=\"\" width=\"334\" height=\"227\" title=\"\"><\/p>\n<p><strong>\u2022 Switchable Reflectance Apertures<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8715 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/8.png\" alt=\"\" width=\"348\" height=\"223\" title=\"\"><\/p>\n<p><strong>\u2022 Four Kinds of UV Test Modes for Fluorescence Material Measurement<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8716 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/6-1.png\" alt=\"\" width=\"314\" height=\"187\" title=\"\"><\/p>\n<p><strong>Instrument Structure Introduction<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8717 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220927150809.png\" sizes=\"(max-width: 340px) 100vw, 340px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220927150809.png 340w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720220927150809-279x400.png 279w\" alt=\"DSCD-920\" width=\"340\" height=\"488\" title=\"\"><\/p>\n<p><strong>Especifica\u00e7\u00e3o:<br \/>\n<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%; height: 792px;\">\n<tbody>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Illumination\/ Viewing System<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\n<p style=\"text-align: left;\">Reflection: d\/8(Diffused illumination, 8 degree viewing)<\/p>\n<p style=\"text-align: left;\">Simultaneous measurement of SCI\/SCE (ISO7724\/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7, JIS Z8722 Condition C standard)<\/p>\n<p style=\"text-align: left;\">Transmittance d\/0(Diffused illumination, 0 degree viewing )<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Sensor<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">Silicon Photodiode Array<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Grating Method<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">Concave Grating<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Di\u00e2metro da esfera<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">152mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Comprimento de onda<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">360-780nm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Wavelength Pitch<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">10nm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Half Band Width<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">5nm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Reflectance Range<\/p>\n<p>Resolu\u00e7\u00e3o<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">0-200%<\/p>\n<p>0.01%<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Light Source<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">Pulse Xenon Lamp and LED<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">UV Measurement<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">Include UV, 400nm, 420nm, 460nm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Tempo de Medi\u00e7\u00e3o<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">SCI\/SCE &lt; 2s<\/p>\n<p>SCI+SCE &lt; 4s<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Measurement Aperture<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">Reflection:<br \/>\nXLAV \u03a625.4mm\/\u03a630mm<br \/>\nLAV\u03a615mm\/\u03a618mm<br \/>\nMAV\u03a68mm\/\u03a611mm<br \/>\nSAV\u03a63mm\/\u03a66mm<br \/>\n(Users can customize the caliber, and the caliber switch will be automatically recognized)<br \/>\nTransmission: \u03a617mm\/\u03a625mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Transmittance Sample Size<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">No limit on sample width and height, thickness \u226450mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Repetibilidade<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\n<p style=\"text-align: left;\">XLAV Spectrum Reflectance\/Transmittance: standard deviation within 0.1%<br \/>\nXLAV chromaticity value: standard deviation \u0394E*ab within 0.015 (after instrument calibration, measure the white calibration plate 30 times at 10 second intervals)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Inter-Instrument Agreement<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">XLAV \u0394E*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23\u2103)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Illuminants<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Language<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">English, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish, Chinese (simple and traditional), Indonesian<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Mostrar<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">Spectral data, spectral graph, colorimetric data, color difference data, color difference graph, pass\/fail judgment, simulated color, color evaluation, haze, liquid color, color deviation<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Viewing Angles<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">2\u00b0 and 10\u00b0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Color Spaces<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">L*a*b, L*C*h, Hunter Lab, Yxy, XYZ<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Other Indices<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\n<p style=\"text-align: left;\">WI(ASTM E313-00,ASTM E313-73,CIE\/ISO, AATCC, Hunter, Taube Berger, Stensby)<\/p>\n<p style=\"text-align: left;\">YI(ASTM D1925, ASTM E313-00, ASTM E313-73), Tint(ASTM E313-00), Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA\/Pt-Co\/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Color Difference<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\u0394E*ab, \u0394E*CH, \u0394E*uv, \u0394E*cmc, \u0394E*94, \u0394E*00, \u0394E*ab(hunter),555 shade sort<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Storage Memory<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">8 GB U Disk for data storage and transfer<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Screen Size<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">7 Inches Touch Screen<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Pot\u00eancia<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">12V\/3A<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Operate Temperature<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">5-40\u2103(40-104F), relative humidity 80% (at 35\u2103) no condensation<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Storage Temperature<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">-20-45\u2103(-4-113F), relative humidity 80% (at 35\u2103) no condensation<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Accessories<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\n<p style=\"text-align: left;\">Power adapter, data cable, transmission fixture, USB flash drive (including management software), black chamber, white board, green board, 0% calibration light shielding cover, 30 mm aperture plate, 18 mm aperture plate, 11 mm aperture plate, 6 mm aperture plate, support table, cuvette, damping handle<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Optional Accessories<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\n<p style=\"text-align: left;\">Heating Fixture for Transmittance, Vertical Support and Pneumatic ram for downward measurement, Reflectance fixture for small size sample, Reflectance Glass Cell Support, Corrosion-Resistant Protective Plate (non-removable), Sample Holder for Fiber, Film Fixture, Transmittance Fixture for Small Aperture, Trolley Case, European Standard Plug, American Standard Plug<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Interface<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">USB, USB-B and RS-232<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Instrument Size<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">465x240x260mm(L*W*H)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Peso<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">10.8KGS<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.4476%; text-align: center; vertical-align: middle;\" width=\"170\">Other Function<\/td>\n<td style=\"width: 74.4246%; text-align: center; vertical-align: middle;\" width=\"501\">\n<p style=\"text-align: left;\">1. Camera to view measurement area;<\/p>\n<p style=\"text-align: left;\">2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement);<\/p>\n<p style=\"text-align: left;\">3. Auto humidity and temperature compensation function.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Padr\u00e3o:<\/strong><br \/>\nISO 7724-1 \u201cPaints and varnishes \u2014 Colorimetry\u201d<br \/>\nCIE No.15 \u201cColorimetry\u201d<br \/>\nASTM E1164 \u201cStandard Practice for Obtaining Spectrometric Data for Object-Color Evaluation\u201d<br \/>\nASTM D1003 \u201cStandard Test Method for Haze and Luminous Transmittance of Transparent Plastics\u201d<br \/>\nDIN 5033-7 \u201cColorimetry; measuring conditions for object colours\u201d<br \/>\nASTM E313 \u201cStandard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates\u201d<br \/>\nASTM D1925 \u201cTest Method for Yellowness Index of Plastics\u201d<br \/>\nJIS Z8722<\/p>\n<p><strong>Aplica\u00e7\u00f5es:<br \/>\n<\/strong>\u2022 Plastic Plate Color Measurement<\/p>\n<div id=\"attachment_14963\" class=\"wp-caption aligncenter\" style=\"width: 293px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14963\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-3.png\" alt=\"\" width=\"283\" height=\"189\" aria-describedby=\"caption-attachment-14963\" title=\"\"><\/p>\n<p id=\"caption-attachment-14963\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Plastic Plate Color Measurement<\/span><\/p>\n<\/div>\n<p>\u2022 Powder Material Color Measurement<\/p>\n<div id=\"attachment_14964\" class=\"wp-caption aligncenter\" style=\"width: 303px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14964\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-4.png\" alt=\"\" width=\"293\" height=\"196\" aria-describedby=\"caption-attachment-14964\" title=\"\"><\/p>\n<p id=\"caption-attachment-14964\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Powder Material Color Measurement<\/span><\/p>\n<\/div>\n<p>\u2022 Petroleum and Oil Color and Transmittance Measurement<\/p>\n<div id=\"attachment_14965\" class=\"wp-caption aligncenter\" style=\"width: 297px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14965\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-3.png\" alt=\"\" width=\"287\" height=\"192\" aria-describedby=\"caption-attachment-14965\" title=\"\"><\/p>\n<p id=\"caption-attachment-14965\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Petroleum and Oil test<\/span><\/p>\n<\/div>\n<p>\u2022 Textile and Yarn Color Measurement<\/p>\n<div id=\"attachment_14966\" class=\"wp-caption aligncenter\" style=\"width: 319px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14966\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-2.png\" alt=\"\" width=\"309\" height=\"207\" aria-describedby=\"caption-attachment-14966\" title=\"\"><\/p>\n<p id=\"caption-attachment-14966\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Textile and Yarn Color Measurement<\/span><\/p>\n<\/div>\n<p>\u2022 Master Batches and other Pellet Material Color Measurement<\/p>\n<div id=\"attachment_14967\" class=\"wp-caption aligncenter\" style=\"width: 204px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14967 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-3.png\" alt=\"\" width=\"194\" height=\"289\" aria-describedby=\"caption-attachment-14967\" title=\"\"><\/p>\n<p id=\"caption-attachment-14967\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Master Batches and other Pellet Material Color Measurement<\/span><\/p>\n<\/div>\n<p>\u2022 Printing Ink and Packing Material Color Measurement<\/p>\n<div id=\"attachment_14968\" class=\"wp-caption aligncenter\" style=\"width: 322px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14968\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/6-2.png\" alt=\"\" width=\"312\" height=\"209\" aria-describedby=\"caption-attachment-14968\" title=\"\"><\/p>\n<p id=\"caption-attachment-14968\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Master Batches and other Pellet Material Color Measurement<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>DSCD-950P Benchtop Spectrophotometer is an intelligent, convenient and high precise spectrophotometer. It adopts 7 inches touch screen, full-spectrum capability, and an Android operating system. Illumination modes include reflection D\/8\u00b0 and transmission D\/0\u00b0 (with UV inclusion\/exclusion measurements). It offers accurate and stable color measurements, a large storage capacity, and robust expansion capabilities on the PC end, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3126,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[157],"class_list":["post-2400","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-dscd-950p"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2400","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/comments?post=2400"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2400\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media\/3126"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media?parent=2400"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/categories?post=2400"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/tags?post=2400"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}