{"id":2535,"date":"2025-06-19T19:36:45","date_gmt":"2025-06-19T11:36:45","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ozone-test-chamber-ozone-aging-test-chamber\/"},"modified":"2025-07-01T11:57:31","modified_gmt":"2025-07-01T03:57:31","slug":"ozone-test-chamber-ozone-aging-test-chamber","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pt\/produtos\/ozone-test-chamber-ozone-aging-test-chamber\/","title":{"rendered":"C\u00e2mara de teste de ozono | C\u00e2mara de teste de envelhecimento por ozono"},"content":{"rendered":"<p><strong>Ozone Test Chamber<\/strong> (or called <strong>Ozone Aging Chamber<\/strong> e <strong>Ozone Aging Test Chamber<\/strong>) is design according to rubber being sensitive characteristic of to ozone, it simulate the environmental to accelerate the rubber aging process by ozone. It compared to different products(test sample) aging result each other according to the same ozone aging test conditions\/standards, and get to comparable aging resistance performance.<\/p>\n<p>The ozone aging test is expose the test sample at the closed, non-illuminated constant ozone concentration air and constant temperature test chamber. The sample is tested at predetermined time, to evaluate ozone aging resistance through the sample\u2019s cracks degree or other measured performance change. Ozone aging included static tensile test and dynamic tensile test. The ozone concentration, temperature, humidity, and sample tensile ratio are very important parameters in this aging test.<\/p>\n<p><strong>Padr\u00e3o:<\/strong><br \/>\n\u2022 ISO 1431-1:2024 (GB\/T 13642-2015) \u201cRubber, vulcanized or thermoplastic \u2013 Resistance to ozone crackingPart 1: Static and dynamic strain testing\u201d;<br \/>\n\u2022 ISO 1431-3:2017 \u201cRubber, vulcanized or thermoplastic \u2013 Resistance to ozone crackingPart 3: Reference and alternative methods for determining the ozone concentration in laboratory test chambers\u201d<br \/>\n\u2022 GB\/T 7762-2014 \u201cRubber, vulcanized or thermoplastic \u2013 Resistance to ozone cracking \u2013 Static strain testing\u201d;<br \/>\n\u2022 ASTM 1149 Standard \u201cTest Methods for Rubber Deterioration \u2013 Cracking in an Ozone Controlled Environment\u201d;<br \/>\n\u2022 ASTM D3041-79 \u201cMethod of Testing Coated Fabrics-Ozone Cracking in a Chamber\u201d;<br \/>\n\u2022 ASTM D1171-18 \u201cStandard Test Method for Rubber Deterioration\u2014Surface Ozone Cracking Outdoors\u201d;<\/p>\n<p><strong>Especifica\u00e7\u00e3o:<\/strong><br \/>\n\u2022 Ozone concentration: 10~1,000pphm (Adjustable);<br \/>\n\u2022 Ozone concentration fluctuation: 2~3pphm;<br \/>\n\u2022 Temperature range: 0\u2103~60\u2103; temperature fluctuation: \u00b11\u2103; temperature uniformity: 2\u2103; temperature deviation: \u00b12\u2103;<br \/>\n\u2022 Humidity range: 20%~90%RH (20\u2103~40\u2103); humidity deviation: \u00b15%.RH; humidity uniformity: 5%RH; humidity fluctuation: \u2264\u00b13%RH;<br \/>\n\u2022 Rotation speed of sample holder: 8~25mm\/s;<br \/>\n\u2022 Fixture stretch rate: 5~45%; stretch frequency: 0~30 times\/min; Maximum stretch length: 0~90mm(Adjustable 15);<br \/>\n\u2022 Tensile test mode:<br \/>\nA. Static tensile mode;<br \/>\nB. Dynamic tensile mode;<br \/>\nC. Intermittent dynamic tensile test mode;<br \/>\n\u2022 Gas flow speed: 600\u00b1100mm\/s (Powerful air circulation mode);<br \/>\n\u2022 Data export: The data can be export to EXCEL format;<br \/>\nA. Use external USB interface to export test data (standard configuration);<br \/>\nB. RJ45 network port remote computer terminal to store test data (optional);<br \/>\n\u2022 Noise: Apply low noise design, the maximum noise: \u226475 dB;<br \/>\n\u2022 Test conditions:<br \/>\nA. Work environment temperature: 0\uff5e30\u2103; relative humidity \u226485%RH;<br \/>\nB. Normal atmospheric pressure;<\/p>\n<table style=\"width: 100.562%; height: 280px;\" width=\"940\">\n<tbody>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\" width=\"103\"><strong>Modelo LISUN<\/strong><\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\" width=\"226\"><strong>Dimens\u00f5es da sala de trabalho (mm)<\/strong><\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\" width=\"237\"><strong>Fonte de alimenta\u00e7\u00e3o em funcionamento<\/strong><\/td>\n<td style=\"width: 35.6197%; vertical-align: middle;\" width=\"374\"><strong>Observa\u00e7\u00e3o<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\">OTC-150A<\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\">500*500*600<\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\">Single Phase\/5kVA<\/td>\n<td style=\"width: 35.6197%; vertical-align: middle;\" rowspan=\"4\" width=\"374\">Controller is in the bottom with single door<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\">OTC-500A<\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\">700*800*900<\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\">Single Phase\/6.5kVA<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\">OTC-010A<\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\">1000*1000*1000<\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\">3Phases\/8.5kVA<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\">OTC-015A<\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\">1000*1500*1000<\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\">3Phases\/10kVA<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\">OTC-020A<\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\">1000*2000*1000<\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\">3Phases\/12kVA<\/td>\n<td style=\"width: 35.6197%; vertical-align: middle;\">Controller is in the bottom with Double Doors<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.071%; vertical-align: middle;\">OTC-035A<\/td>\n<td style=\"width: 24.3081%; vertical-align: middle;\">1500*1500*1500<\/td>\n<td style=\"width: 27.9182%; vertical-align: middle;\">3Phases\/13kVA<\/td>\n<td style=\"width: 35.6197%; vertical-align: middle;\">Controller is the back with Double Doors<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>System Configuration<\/strong>:<br \/>\n\u2022 Control system: 7-inch industrial-grade touch control computer with Win CE platform equipped with self-developed ozone control software;<br \/>\n\u2022 Ozone generator: use voltage silent discharge tube to generate ozone;<br \/>\n\u2022 Sensor: The acquisition accuracy of the ozone detection probe is \u2264\u00b15%; F.S Range: 10\uff5e1000pphm Resolution: 1pphm;<br \/>\n\u2022 Temperature sensor: Adopt German Heshi Class A with PT100 sensor;<br \/>\n\u2022 Wind speed control: brushless DC motor centrifugal fan control;<br \/>\n\u2022 Turntable speed control: brushless DC motor control;<br \/>\n\u2022 Stretching control: servo motor control;<br \/>\n\u2022 Cabinet:<br \/>\nA: Inner box material: 1.2mm SUS304;<br \/>\nB: Outer box material: 1.2mm iron plate with powder spray paint;<br \/>\n\u2022 Dedicated rotating frame: professional rotating frame and special sample fixture design, SUS304 anti-corrosion material;<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-otc-150a-ozone-test-chamber-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN OTC-150A Ozone Test Chamber \u2013 After-sales Frequently Asked Questions (FAQ)<\/span><\/a><br \/>\n<\/strong>LISUN OTC-150A Ozone Test Chamber were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ozone Test Chamber (or called Ozone Aging Chamber and Ozone Aging Test Chamber) is design according to rubber being sensitive characteristic of to ozone, it simulate the environmental to accelerate the rubber aging process by ozone. It compared to different products(test sample) aging result each other according to the same ozone aging test conditions\/standards, and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3549,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[288],"class_list":["post-2535","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-otc-150a"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/comments?post=2535"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2535\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media\/3549"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media?parent=2535"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/categories?post=2535"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/tags?post=2535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}