{"id":2848,"date":"2025-06-19T19:41:24","date_gmt":"2025-06-19T11:41:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60884-1-clause-30-1-figure-41-iec-60811-3-1-clause-8-high-temperature-pressure-test-device\/"},"modified":"2025-06-25T13:13:07","modified_gmt":"2025-06-25T05:13:07","slug":"iec-60884-1-clause-30-1-figure-41-iec-60811-3-1-clause-8-high-temperature-pressure-test-device","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/pt\/produtos\/iec-60884-1-clause-30-1-figure-41-iec-60811-3-1-clause-8-high-temperature-pressure-test-device\/","title":{"rendered":"IEC 60884-1 Clause 30.1 Figure 41 | IEC 60811-3-1 Clause 8 | High Temperature Pressure Test Device"},"content":{"rendered":"<p>The GNGPL-3610-2PA High Temperature Pressure Test Device is according to IEC 60884-1:2022 Clause 30.1 Figure 41 (GB\/T 2099.1-2021 Clause 30.1 Figure 41) and IEC 60811-3-1:2020 Clause 8 Figures 1, 2 and 3 (GB\/T 2951.31-2008 Clause 8 Figures 1, 2 and 3). It is suitable for the insulation and sheath heat resistance test of plugs with insulating sheaths, cables\/optical cables with a diameter greater than 0.4mm.<\/p>\n<p>Test principle: Use a 0.7mm thick round or rectangular blade to apply a certain gravity to the sample in a high temperature environment, measure the indentation depth after the test, and thus achieve the detection of the high temperature resistance of the sample.<\/p>\n<p><strong>Padr\u00e3o:<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d Clause 30.1 Figure 41<br \/>\nIEC 60811-3-1 (GB\/T 2951.31) \u201cCommon test methods for insulating and sheathing materials of electric cables \u2013 Part 3: Methods specific to PVC compounds \u2013 Section One: Pressure test at high temperature \u2013 Tests for resistance to cracking\u201d<\/p>\n<p><strong>Especifica\u00e7\u00e3o:<\/strong><\/p>\n<table style=\"width: 100.387%; height: 571px;\" width=\"575\">\n<tbody>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\"><strong>Modelo LISUN<\/strong><\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\"><strong>GNGPL-3610-2PA<\/strong><\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\" width=\"201\"><strong>GNGPL-3610-3PA<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Working Station<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\">2 working station<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\" width=\"201\">3 working station<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Blade<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\">1pc rectangular blade and 1pc \u03a66 round blade<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\">3pcs rectangular blades<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Blade thickness<\/td>\n<td style=\"width: 78.1694%; vertical-align: middle;\" colspan=\"2\" width=\"402\">0.7\u00b10.01mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Weights<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\">2.5N Weights (Contains the weight of the blade): 2pcs<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\">1~1kg Weights: 3sets<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Heating temperature<\/td>\n<td style=\"width: 78.1694%; vertical-align: middle;\" colspan=\"2\" width=\"201\">200\u2103 or temperature according to the cable specified (Work together with <a href=\"https:\/\/www.lisungroup.com\/products\/environmental-test-chamber\/high-and-low-temperature-humidity-chamber.html\" target=\"_blank\" rel=\"noopener\">LISUN GW-225 High Temperature Chamber<\/a>)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Tempo de teste<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\">2h<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\">D\u226415mm test for 4h; D&gt;15mm test for 6h<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Cooling transition time<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\">10s<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\">Rapid cooling, cold water spray method can be used<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">Qualified judgment<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\" width=\"201\">Diren depth less than or equal to 50%<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\">The median value of the indentation depth is less than or equal to 50% of the average value of the sample thickness<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.0968%; vertical-align: middle;\" width=\"173\">According to the standards<\/td>\n<td style=\"width: 39.6071%; vertical-align: middle;\">IEC 60884-1 Clause 30.1 Figure 41<\/td>\n<td style=\"width: 38.5623%; vertical-align: middle;\">IEC 60811-3-1 Clause 8 Figures 1, 2 and 3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_14295\" class=\"wp-caption aligncenter\" style=\"width: 983px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14295 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/44.jpg\" sizes=\"(max-width: 973px) 100vw, 973px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/44.jpg 973w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/44-400x277.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/03\/44-768x533.jpg 768w\" alt=\"\" width=\"973\" height=\"675\" aria-describedby=\"caption-attachment-14295\" title=\"\"><\/p>\n<p id=\"caption-attachment-14295\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Figure 41 Test Apparatus for pres test at high temperature<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The GNGPL-3610-2PA High Temperature Pressure Test Device is according to IEC 60884-1:2022 Clause 30.1 Figure 41 (GB\/T 2099.1-2021 Clause 30.1 Figure 41) and IEC 60811-3-1:2020 Clause 8 Figures 1, 2 and 3 (GB\/T 2951.31-2008 Clause 8 Figures 1, 2 and 3). It is suitable for the insulation and sheath heat resistance test of plugs with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3277,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[542],"class_list":["post-2848","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-gngpl-3610-2pa"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/comments?post=2848"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/posts\/2848\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media\/3277"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/media?parent=2848"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/categories?post=2848"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/pt\/wp-json\/wp\/v2\/tags?post=2848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}