{"id":2380,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/scientific-grade-ccd-spectroradiometer\/"},"modified":"2025-06-27T14:05:44","modified_gmt":"2025-06-27T06:05:44","slug":"scientific-grade-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/scientific-grade-ccd-spectroradiometer\/","title":{"rendered":"\u0421\u043f\u0435\u043a\u0442\u0440\u043e\u0440\u0430\u0434\u0438\u043e\u043c\u0435\u0442\u0440 CCD \u043d\u0430\u0443\u0447\u043d\u043e\u0433\u043e \u043a\u043b\u0430\u0441\u0441\u0430"},"content":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.<\/p>\n<p><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u041c\u041a\u041e 177<\/a> \u00ab\u0426\u0432\u0435\u0442\u043e\u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u0431\u0435\u043b\u044b\u0445 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u0441\u0432\u0435\u0442\u0430\u00bb<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u0432\u0435\u0442\u043e\u0432\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u041c\u041a\u041e-13.3<\/a> \u00ab\u041c\u0435\u0442\u043e\u0434 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u0438 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0446\u0432\u0435\u0442\u043e\u043f\u0435\u0440\u0435\u0434\u0430\u044e\u0449\u0438\u0445 \u0441\u0432\u043e\u0439\u0441\u0442\u0432 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u0441\u0432\u0435\u0442\u0430\u00bb<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"\u041e\u043f\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u0442\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043e\u0441\u0432\u0435\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439 \u0444\u043e\u0440\u043c\u0430\u0442 \u0444\u0430\u0439\u043b\u043e\u0432 IESNA \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0438 \u0444\u043e\u0442\u043e\u043c\u0435\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 \u0438 \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u0432\u0435\u0442\u043e\u0432\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u0441\u0432\u0435\u0442\u0430\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043d\u0430 \u0446\u0432\u0435\u0442\u043d\u043e\u0441\u0442\u044c \u0442\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043e\u0441\u0432\u0435\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432 \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043b\u0430\u043c\u043f\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(\u0415\u0421) 2019\/2015<\/a> \"\u0414\u0415\u041b\u0415\u0413\u0418\u0420\u041e\u0412\u0410\u041d\u041d\u041e\u0415 \u041f\u041e\u0421\u0422\u0410\u041d\u041e\u0412\u041b\u0415\u041d\u0418\u0415 \u041a\u041e\u041c\u0418\u0421\u0421\u0418\u0418\"<\/p>\n<p><strong>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f:<\/strong><br \/>\n\u2022 CCD detector: Hamamatsu TE-cooled (Temp: -10\u00b0C \u00b10.05\u00b0C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)<br \/>\n- \u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0441\u043f\u0435\u043a\u0442\u0440\u0430\u043b\u044c\u043d\u043e\u0439 \u0434\u043b\u0438\u043d\u044b \u0432\u043e\u043b\u043d\u044b: \u00b10,2 \u043d\u043c, \u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435: \u00b10,1 \u043d\u043c, \u0428\u0430\u0433 \u0441\u043a\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043e\u0431\u0440\u0430\u0437\u0446\u0430: \u00b10,1 \u043d\u043c<br \/>\n- \u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u043e\u0440\u0434\u0438\u043d\u0430\u0442 \u0446\u0432\u0435\u0442\u043d\u043e\u0441\u0442\u0438 (\u0394x, \u0394y): \u00b10,0015 (\u043f\u0440\u0438 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u043e\u0439 \u043b\u0430\u043c\u043f\u0435 A)<br \/>\n- \u041a\u043e\u0440\u0440\u0435\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u0430\u044f \u0446\u0432\u0435\u0442\u043e\u0432\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 CCT: 1, 500K~100, 000K, \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c CCT: \u00b10.2%<br \/>\n- \u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0438\u043d\u0434\u0435\u043a\u0441\u0430 \u0446\u0432\u0435\u0442\u043e\u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0438: 0~100.0, \u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c: \u00b1(0.3%rd\u00b10.3)<br \/>\n\u2022 Photometric linear: \u00b10.2%, Stray light: &lt;0.015%(600nm) and &lt;0.03% (435nm)<br \/>\n- \u0412\u0440\u0435\u043c\u044f \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f: 0,1 \u043c\u0441 - 60 \u0441<br \/>\n- \u041e\u043d \u043c\u043e\u0436\u0435\u0442 \u0438\u0437\u043c\u0435\u0440\u044f\u0442\u044c \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0443 \u0432\u043d\u0443\u0442\u0440\u0438 \u0438 \u0441\u043d\u0430\u0440\u0443\u0436\u0438 \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u044e\u0449\u0435\u0439 \u0441\u0444\u0435\u0440\u044b<br \/>\n\u2022 Flux testing method: spectrum, photometric, spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>\u041c\u043e\u0434\u0435\u043b\u044c LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CSWIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>\u0414\u043b\u0438\u043d\u0430 \u0432\u043e\u043b\u043d\u044b<\/strong><\/td>\n<td style=\"width: 20%;\">350-800 \u043d\u043c<\/td>\n<td style=\"width: 20%;\">200-800 \u043d\u043c<\/td>\n<td style=\"width: 20%;\">350-1050 \u043d\u043c<\/td>\n<td style=\"width: 20%;\">800-1700nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">\u0412\u044b\u0441\u043e\u043a\u043e\u0442\u043e\u0447\u043d\u044b\u0439 \u0441\u043f\u0435\u043a\u0442\u0440\u043e\u0440\u0430\u0434\u0438\u043e\u043c\u0435\u0442\u0440 LISUN LPCE-2(LMS-9500C) \u0441 \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u044e\u0449\u0435\u0439 \u0441\u0444\u0435\u0440\u043e\u0439 - \u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b (FAQ) \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u043e\u0434\u0430\u0436\u0438.<\/span><\/a><br \/>\n<\/strong>\u0412\u044b\u0441\u043e\u043a\u043e\u0442\u043e\u0447\u043d\u044b\u0439 \u0441\u043f\u0435\u043a\u0442\u0440\u043e\u0440\u0430\u0434\u0438\u043e\u043c\u0435\u0442\u0440 LISUN LPCE-2(LMS-9500C), \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u044e\u0449\u0438\u0439 \u0441\u0444\u0435\u0440\u0438\u0447\u0435\u0441\u043a\u0443\u044e \u0441\u0438\u0441\u0442\u0435\u043c\u0443, \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u043d\u0430 \u0440\u044b\u043d\u043a\u0435 \u0443\u0436\u0435 \u0431\u043e\u043b\u0435\u0435 10 \u043b\u0435\u0442, \u043a\u043e\u043c\u0430\u043d\u0434\u0430 \u0438\u043d\u0436\u0435\u043d\u0435\u0440\u043e\u0432 LISUN \u0443\u0436\u0435 \u043e\u0431\u043e\u0431\u0449\u0438\u043b\u0430 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u0432\u043e\u043f\u0440\u043e\u0441\u043e\u0432 \u0438 \u043e\u0442\u0432\u0435\u0442\u043e\u0432 \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u043e\u0434\u0430\u0436\u0438 \u0432 \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u043d\u043e\u0439 \u0432\u044b\u0448\u0435 \u0441\u0441\u044b\u043b\u043a\u0435. \u041f\u043e\u0436\u0430\u043b\u0443\u0439\u0441\u0442\u0430, \u0432\u043d\u0438\u043c\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u0439\u0442\u0435 \u0438\u0445, \u0438 \u0432\u044b \u0441\u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u0430\u043c\u043e\u0441\u0442\u043e\u044f\u0442\u0435\u043b\u044c\u043d\u043e \u0440\u0435\u0448\u0438\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043f\u0440\u043e\u0431\u043b\u0435\u043c, \u0435\u0441\u043b\u0438 \u0443 \u0432\u0430\u0441 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u0443\u0442 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u043f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432. LISUN \u0431\u0443\u0434\u0435\u0442 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0430\u0442\u044c \u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0442\u044c \u044d\u0442\u0438 \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b, \u0438 \u0431\u043e\u043b\u044c\u0448\u0435 FAQ \u043c\u043e\u0436\u043d\u043e \u043d\u0430\u0439\u0442\u0438 \u0432 \u044d\u0442\u043e\u0439 \u0442\u0435\u043c\u0435 \u043f\u043e \u0441\u0441\u044b\u043b\u043a\u0435.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[137],"class_list":["post-2380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9500c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2380"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/4774"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2380"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}