{"id":2406,"date":"2025-06-19T19:35:35","date_gmt":"2025-06-19T11:35:35","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ccd-spectroradiometer\/"},"modified":"2025-06-27T14:48:26","modified_gmt":"2025-06-27T06:48:26","slug":"ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/ccd-spectroradiometer\/","title":{"rendered":"\u041f\u0417\u0421-\u0441\u043f\u0435\u043a\u0442\u0440\u043e\u0440\u0430\u0434\u0438\u043e\u043c\u0435\u0442\u0440"},"content":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy.<br \/>\n\u2022\u00a0The following wavelength range is with 0.8nm FWHM:<\/p>\n<table border=\"1\" width=\"921\" cellspacing=\"1\" cellpadding=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td>LMS-7000UV<\/td>\n<td>LMS-7000UV-VIS<\/td>\n<td>LMS-7000VIS<\/td>\n<td>LMS-7000VIS-NIR<\/td>\n<td>LMS-7000UV-VIS-NIR<\/td>\n<\/tr>\n<tr>\n<td>200~400nm<\/td>\n<td>200~800nm<\/td>\n<td>350~950nm<\/td>\n<td>350~1050nm<\/td>\n<td>200~1050nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u2022 Integration time: 0.5ms to 1,0000ms<br \/>\n\u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm<br \/>\n\u2022\u00a0SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A\/D is 16bit<br \/>\n\u2022 Communicate with PC by USB2.0. The software has a rich re-develop platform which can run on Win7, Win8, Win10, Win11<br \/>\n\u2022 Optical fiber port is SMA905<\/p>\n<p><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"\u041e\u043f\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u0442\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043e\u0441\u0432\u0435\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439 \u0444\u043e\u0440\u043c\u0430\u0442 \u0444\u0430\u0439\u043b\u043e\u0432 IESNA \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043d\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0438 \u0444\u043e\u0442\u043e\u043c\u0435\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 \u0438 \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u0439 \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u0438\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u041c\u041a\u041e 177<\/a> \u00ab\u0426\u0432\u0435\u0442\u043e\u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u0431\u0435\u043b\u044b\u0445 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u0441\u0432\u0435\u0442\u0430\u00bb<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435 \u0441\u0432\u0435\u0442\u043e\u0432\u043e\u0433\u043e \u043f\u043e\u0442\u043e\u043a\u0430\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u041c\u041a\u041e-13.3<\/a> \u00ab\u041c\u0435\u0442\u043e\u0434 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u0438 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044f \u0446\u0432\u0435\u0442\u043e\u043f\u0435\u0440\u0435\u0434\u0430\u044e\u0449\u0438\u0445 \u0441\u0432\u043e\u0439\u0441\u0442\u0432 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u0441\u0432\u0435\u0442\u0430\u00bb<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f \u043d\u0430 \u0446\u0432\u0435\u0442\u043d\u043e\u0441\u0442\u044c \u0442\u0432\u0435\u0440\u0434\u043e\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043e\u0441\u0432\u0435\u0442\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432 \u0434\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043b\u0430\u043c\u043f\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(\u0415\u0421) 2019\/2015<\/a> \"\u0414\u0415\u041b\u0415\u0413\u0418\u0420\u041e\u0412\u0410\u041d\u041d\u041e\u0415 \u041f\u041e\u0421\u0422\u0410\u041d\u041e\u0412\u041b\u0415\u041d\u0418\u0415 \u041a\u041e\u041c\u0418\u0421\u0421\u0418\u0418\"<\/p>\n<p><strong>Typical Application:<br \/>\n<\/strong>The LMS-7000 is for LED color &amp; lumen test. It works with <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">integrating sphere<\/a> and standard lamp as a system: <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/ccd-spectroradiometer-integrating-sphere-compact-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-3 CCD \u0421\u043f\u0435\u043a\u0442\u0440\u043e\u0440\u0430\u0434\u0438\u043e\u043c\u0435\u0442\u0440 \u0418\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u044e\u0449\u0430\u044f \u0441\u0444\u0435\u0440\u0430 \u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430<\/a>. This system can do the following test.<\/p>\n<p><strong>\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435:<br \/>\n<\/strong>Colorimetric: Chromaticity Coordinate (x, y) and (u, v), Relative Spectral Power Distribution P(\u03bb), Correlated Color Temperature (Tc), Color Rendering Index (Ra, R1 to R15), Color Difference, Dominant Wavelength, Peak Wavelength, Half-bandwidth, Spectral Purity, TM30 (Rf, Rg), CQS<br \/>\nPhotometric: Luminous Flux (Lumen), Luminous Efficiency, Radiant Power, EEI, PAR, PPF<br \/>\nElectrical: Voltage, Current, Power, Power Factor, Harmonic (Optional)<\/p>\n<p><strong>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f:<br \/>\n<\/strong>\u2022\u00a0Spectral Resolution: \u00b10.2nm<br \/>\n\u2022\u00a0Reproducibility: \u00b10.5nm<br \/>\n\u2022\u00a0Accuracy of Chromaticity Coordinate (\u0394x, \u0394y): \u00b10.003<br \/>\n\u2022 Correlated Color Temperature CCT: 1, 500K ~ 25, 000K, CCT Accuracy:\u00b10.5%<br \/>\n\u2022 High spectral resolution, high sensitivity and excellent reliability<\/p>\n<p><strong>Other Applications:<br \/>\n<\/strong>The LMS-7000 can also work with other accessories. It can be used in the following field and area. Please contact LISUN sales dept for the detail solution and spectroradiometer price.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-1990 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg 700w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer-400x180.jpg 400w\" alt=\"LMS-7000 CCD Spectroradiometer\" width=\"700\" height=\"315\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-3-ccd-spectroradiometer-integrating-sphere-compact-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-3 (LMS-7000) CCD \u0441\u043f\u0435\u043a\u0442\u0440\u043e\u0440\u0430\u0434\u0438\u043e\u043c\u0435\u0442\u0440 \u0438\u043d\u0442\u0435\u0433\u0440\u0438\u0440\u0443\u044e\u0449\u0438\u0439 \u0441\u0444\u0435\u0440\u0443 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430 - \u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b (FAQ) \u043f\u043e\u0441\u043b\u0435 \u043f\u0440\u043e\u0434\u0430\u0436\u0438\u00a0<\/span><\/a><br \/>\n<\/strong>\u0421\u0438\u0441\u0442\u0435\u043c\u0430 LISUN LPCE-3 \u0441\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u043d\u0430 \u0440\u044b\u043d\u043a\u0435 \u0443\u0436\u0435 \u0431\u043e\u043b\u0435\u0435 10 \u043b\u0435\u0442, \u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u0438\u0441\u0442\u044b \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u043e\u0439 \u0441\u043b\u0443\u0436\u0431\u044b LISUN \u0443\u0436\u0435 \u043e\u0431\u043e\u0431\u0449\u0438\u043b\u0438 \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u0432\u043e\u043f\u0440\u043e\u0441\u043e\u0432 \u0438 \u043e\u0442\u0432\u0435\u0442\u043e\u0432 \u043f\u043e \u043f\u043e\u0441\u043b\u0435\u043f\u0440\u043e\u0434\u0430\u0436\u043d\u043e\u043c\u0443 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044e, \u043f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u0445 \u0432\u044b\u0448\u0435. \u041f\u043e\u0436\u0430\u043b\u0443\u0439\u0441\u0442\u0430, \u0432\u043d\u0438\u043c\u0430\u0442\u0435\u043b\u044c\u043d\u043e \u043f\u0440\u043e\u0447\u0438\u0442\u0430\u0439\u0442\u0435 \u0435\u0435, \u0438 \u0432\u044b \u0441\u043c\u043e\u0436\u0435\u0442\u0435 \u0441\u0430\u043c\u043e\u0441\u0442\u043e\u044f\u0442\u0435\u043b\u044c\u043d\u043e \u0440\u0435\u0448\u0438\u0442\u044c \u0431\u043e\u043b\u044c\u0448\u0438\u043d\u0441\u0442\u0432\u043e \u043f\u0440\u043e\u0431\u043b\u0435\u043c, \u0435\u0441\u043b\u0438 \u0443 \u0432\u0430\u0441 \u0432\u043e\u0437\u043d\u0438\u043a\u043d\u0443\u0442 \u0432\u043e\u043f\u0440\u043e\u0441\u044b \u043f\u0440\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0438 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432. LISUN \u0431\u0443\u0434\u0435\u0442 \u043f\u0440\u043e\u0434\u043e\u043b\u0436\u0430\u0442\u044c \u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0442\u044c \u044d\u0442\u0438 \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u044b, \u0438 \u0431\u043e\u043b\u044c\u0448\u0435 FAQ \u043c\u043e\u0436\u043d\u043e \u043d\u0430\u0439\u0442\u0438 \u0432 \u044d\u0442\u043e\u0439 \u0442\u0435\u043c\u0435 \u043f\u043e \u0441\u0441\u044b\u043b\u043a\u0435.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy. \u2022\u00a0The following wavelength range is with 0.8nm FWHM: LMS-7000UV LMS-7000UV-VIS LMS-7000VIS LMS-7000VIS-NIR LMS-7000UV-VIS-NIR 200~400nm 200~800nm 350~950nm 350~1050nm 200~1050nm \u2022 Integration time: 0.5ms to 1,0000ms \u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm \u2022\u00a0SNR (Signal to Noise Ratio) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3423,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[163],"class_list":["post-2406","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-7000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2406","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2406"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2406\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/3423"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2406"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2406"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2406"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}