{"id":2458,"date":"2025-06-19T19:35:58","date_gmt":"2025-06-19T11:35:58","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/damped-oscillatory-magnetic-field-immunity-tester\/"},"modified":"2025-07-03T15:15:19","modified_gmt":"2025-07-03T07:15:19","slug":"damped-oscillatory-magnetic-field-immunity-tester","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/damped-oscillatory-magnetic-field-immunity-tester\/","title":{"rendered":"IEC 61000-4-10 EM Test"},"content":{"rendered":"<p>DOMF61000-10 damped oscillatory magnetic field immunity test system includes damped oscillating wave generator and single ring coil. It\u2019s designed for damping oscillation magnetic field immunity test.<\/p>\n<p><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442:<\/strong><br \/>\nIEC 61000-4-10, EN61000-4-10\/GB\/T 17626.10 \u201cElectromagnetic compatibility (EMC) \u2013 Part 4-10: Testing and measurement techniques; Damped oscillatory magnetic field immunity test; Amendment 1\u201d<br \/>\nIEC 255-22-1 \u201camortie 1 MHz Electrical relays \u2013 Part 22-1: Electrical disturbance tests for measuring relays and protection equipment \u2013 1 MHz burst immunity tests\u201d<br \/>\nIEC 255-22-3 \u201cMeasuring relays and protection equipment \u2013 Part 22-3: Electrical disturbance tests \u2013 Radiated electromagnetic field immunity \u201c<br \/>\nANSI C37.90 \u201cRelays and Relay Systems Associated with Electric Power Apparatus \u201c<br \/>\nGB\/T 14598.13 \u201cElectrical disturbance tests for measuring relays and protection equipment Part 1: 1 MHz burst disturbance \u201c<\/p>\n<p><strong>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f:<\/strong><\/p>\n<table style=\"width: 100.492%; height: 216px;\" border=\"1\" width=\"968\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Magnetic Field Strength<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">0~100A\/m<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Oscillation Frequency<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">100kHz, 1MHz<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Pulse Polarity<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">Positive, Negative or Positive\/Negative automatic<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Rise Time<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">75ns\u00b120%<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Attenuation<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">Attenuation to half value of first peak within fifth peak to tenth peak<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Repeat Frequency<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">1~80Hz(oscillation frequency: 100kHz)-Adjustable; 1~500Hz(oscillation frequency: 1MHz)-Adjustable<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Burst Width<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">1\uff5e9999s(Adjustable)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Pulse Interval<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">1\uff5e9999s(Adjustable)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 20.0839%; vertical-align: middle; height: 24px;\" width=\"207\">Test Function<\/td>\n<td style=\"width: 77.2465%; vertical-align: middle; height: 24px;\" width=\"346\">Built-in IEC standard test levels; Step voltage; Big LCD touch screen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>DOMF61000-10 damped oscillatory magnetic field immunity test system includes damped oscillating wave generator and single ring coil. It\u2019s designed for damping oscillation magnetic field immunity test. Standard: IEC 61000-4-10, EN61000-4-10\/GB\/T 17626.10 \u201cElectromagnetic compatibility (EMC) \u2013 Part 4-10: Testing and measurement techniques; Damped oscillatory magnetic field immunity test; Amendment 1\u201d IEC 255-22-1 \u201camortie 1 MHz Electrical [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3195,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[212],"class_list":["post-2458","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-domf61000-10"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2458"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2458\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/3195"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2458"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2458"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2458"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}