{"id":2477,"date":"2025-06-19T19:36:10","date_gmt":"2025-06-19T11:36:10","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/electronic-ballast-analyzer\/"},"modified":"2025-06-25T18:11:18","modified_gmt":"2025-06-25T10:11:18","slug":"electronic-ballast-analyzer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/electronic-ballast-analyzer\/","title":{"rendered":"Electronic Ballast Analyzer"},"content":{"rendered":"<p>The WT3000 electronic fluorescent ballast testing equipment meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GB\/T15144-2005 and GB\/T17263-1998.<\/p>\n<p><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60929-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60929<\/a>\u00a0\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T15144-2005 \u201c<\/a>AC and\/or DC-supplied electronic control gear for tubular fluorescent lamps \u2013 Performance requirements\u201d<br \/>\nIEC 60969 \u201c\u0421\u0430\u043c\u043e\u0431\u0430\u043b\u043b\u0430\u0441\u0442\u043d\u044b\u0435 \u043a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0435 \u043b\u044e\u043c\u0438\u043d\u0435\u0441\u0446\u0435\u043d\u0442\u043d\u044b\u0435 \u043b\u0430\u043c\u043f\u044b \u0434\u043b\u044f \u043e\u0431\u0449\u0435\u0433\u043e \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f \u2013 \u0422\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u044f \u043a \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430\u043c\u201d<br \/>\nIEC 61000-3-2\/\u00a0<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17625.1-2003-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T-17625.1<\/a> \u201c\u041f\u043e\u043f\u0440\u0430\u0432\u043a\u0430 1 \u2013 \u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u0430\u044f \u0441\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c (\u042d\u041c\u0421) \u2013 \u0427\u0430\u0441\u0442\u044c 3-2: \u041f\u0440\u0435\u0434\u0435\u043b\u044b \u2013 \u041f\u0440\u0435\u0434\u0435\u043b\u044b \u0438\u0437\u043b\u0443\u0447\u0435\u043d\u0438\u044f \u0433\u0430\u0440\u043c\u043e\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0442\u043e\u043a\u043e\u0432 (\u0432\u0445\u043e\u0434\u043d\u043e\u0439 \u0442\u043e\u043a \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u226416 \u0410 \u043d\u0430 \u0444\u0430\u0437\u0443)\u201d<\/p>\n<p><strong>\u0418\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u0435:<br \/>\n<\/strong>\u2022 Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic<br \/>\n\u2022 Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis<br \/>\n\u2022 Startup: lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time<\/p>\n<p><strong>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438:\u00a0\u00a0<\/strong><br \/>\n\u2022 It has 8 windows to display each parameter of input and output characteristics<br \/>\n\u2022 Frequency response for testing input current up to 1MHz, suitable for precise testing of various kind of electronic ballast<br \/>\n\u2022 WT3000 has expanding analysis for envelope wave.<br \/>\n\u2022 Symmetry analysis for envelope wave\u2019s crest factor of lamp current<br \/>\n\u2022 Sampling at ultra-high speed, dynamic analysis single frequency curve, highest sampling frequency is up to 10MHz<br \/>\n\u2022 Portable with built-in chip micro-processor, particular suitable for development and spot production<br \/>\n\u2022 RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7<\/p>","protected":false},"excerpt":{"rendered":"<p>The WT3000 electronic fluorescent ballast testing equipment meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GB\/T15144-2005 and GB\/T17263-1998. Standard: IEC 60929\u00a0\/GB\/T15144-2005 \u201cAC and\/or DC-supplied electronic control gear for tubular fluorescent lamps \u2013 Performance requirements\u201d IEC 60969 \u201cSelf-ballasted compact fluorescent lamps for general lighting services \u2013 Performance requirements\u201d [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3768,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[231],"class_list":["post-2477","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-wt3000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2477","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2477"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2477\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/3768"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2477"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2477"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2477"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}