{"id":2500,"date":"2025-06-19T19:36:21","date_gmt":"2025-06-19T11:36:21","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-605982024-touch-current-measuring-network-g-2-and-g-3\/"},"modified":"2025-06-25T18:05:41","modified_gmt":"2025-06-25T10:05:41","slug":"iec-605982024-touch-current-measuring-network-g-2-and-g-3","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/iec-605982024-touch-current-measuring-network-g-2-and-g-3\/","title":{"rendered":"IEC 60598:2024 Touch Current Measuring Network G.2 and G.3"},"content":{"rendered":"<p>G.2 and G.3 Measuring network, touch current weighted for perception or reaction and let-go, and is designed according to IEC 60598-1:2024 Figure G.2 and Figure G.3, IEC 60990:2016 Clause 5.1.1 Figure 4 and Figure 5. The two figures are integrated into one temperature measuring box.<\/p>\n<p><strong>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u0435<\/strong>: It should work together with LISUN <a href=\"https:\/\/www.lisungroup.com\/products\/electrical-safety-tester\/touch-current-measuring-network-g-1.html\" target=\"_blank\" rel=\"noopener\">MNTC-G1<\/a>\u00a0\u0438\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/electrical-safety-tester\/iec60598-figure-g-4-simulated-human-impedance-touch-current-measuring-network.html\" target=\"_blank\" rel=\"noopener\">MNTC-G4<\/a>.<\/p>\n<p><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442:<\/strong><br \/>\nIEC 60598-1 \u201cLuminaires \u2013 Part 1: General requirements and tests\u201d Figure G.2 and Figure G.3<br \/>\nIEC 60990 \u201cMethods of measurement of touch current and protective conductor current\u201d Clause 5.1.1 Figure 4 and Figure 5<\/p>\n<p>The standard requirements are as follow:<\/p>\n<div id=\"attachment_15806\" class=\"wp-caption aligncenter\" style=\"width: 911px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-15806 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC-60598-2014-Figure-G2-and-G3.jpg\" sizes=\"(max-width: 901px) 100vw, 901px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC-60598-2014-Figure-G2-and-G3.jpg 901w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC-60598-2014-Figure-G2-and-G3-400x359.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC-60598-2014-Figure-G2-and-G3-768x690.jpg 768w\" alt=\"\" width=\"901\" height=\"809\" aria-describedby=\"caption-attachment-15806\" title=\"\"><\/p>\n<p id=\"caption-attachment-15806\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60598: 2014 Figure G2 And G3<\/span><\/p>\n<\/div>\n<div id=\"attachment_15807\" class=\"wp-caption aligncenter\" style=\"width: 735px;\">\n<p><img decoding=\"async\" class=\"wp-image-15807 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60990-Figure-4-and-Figure-5.png\" sizes=\"(max-width: 725px) 100vw, 725px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60990-Figure-4-and-Figure-5.png 725w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60990-Figure-4-and-Figure-5-400x359.png 400w\" alt=\"IEC60990 Figure 4 And Figure 5\" width=\"725\" height=\"651\" aria-describedby=\"caption-attachment-15807\" title=\"\"><\/p>\n<p id=\"caption-attachment-15807\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC60990 Figure 4 And Figure 5<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>G.2 and G.3 Measuring network, touch current weighted for perception or reaction and let-go, and is designed according to IEC 60598-1:2024 Figure G.2 and Figure G.3, IEC 60990:2016 Clause 5.1.1 Figure 4 and Figure 5. The two figures are integrated into one temperature measuring box. Note: It should work together with LISUN MNTC-G1\u00a0and\u00a0MNTC-G4. Standard: IEC [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3546,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[253],"class_list":["post-2500","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-mntc-g2g3"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2500","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2500"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2500\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/3546"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2500"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2500"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2500"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}