{"id":2863,"date":"2025-06-19T19:41:24","date_gmt":"2025-06-19T11:41:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60884-1-clause-24-13-15-figure-34-iec-60669-1-clause-20-5-7-figure-13-test-device-for-verification-of-cover-and-cover-plates\/"},"modified":"2025-06-25T13:21:50","modified_gmt":"2025-06-25T05:21:50","slug":"iec-60884-1-clause-24-13-15-figure-34-iec-60669-1-clause-20-5-7-figure-13-test-device-for-verification-of-cover-and-cover-plates","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/iec-60884-1-clause-24-13-15-figure-34-iec-60669-1-clause-20-5-7-figure-13-test-device-for-verification-of-cover-and-cover-plates\/","title":{"rendered":"IEC 60884-1 Clause 24.13-15 Figure 34 | IEC 60669-1 Clause 20.5-7 Figure 13 Test Device for Verification of Cover and Cover plates"},"content":{"rendered":"<p>LS-B14 Test Device for Verification of Cover and Cover plates fully meets requirements of IEC 60884-1:2022 Clause 24.13-15 Figure 34 (GB\/T 2099.1-2021 Clause 24.15-17 and Figure 31), IEC 60669-1:2017 Clause 20.5-7 Figure 13 (GB\/T 16915.1-2024 Clause 20.4-6 and Figure 19). <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It is used to verify the force required to make the cover or cover plate of a switch or socket or other parts fall out or not fall out. The push-pull force gauge is used to push or pull the sample with different force values \u200b\u200bto determine the safety of the cover or cover plate during reuse.<\/span><\/span><\/span><\/p>\n<p><strong>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442:<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d Clause 24.13-15 Figure 34<br \/>\nIEC 60669-1 (GB\/T 16915.1) \u201cSwitches for household and similar fixed-electrical installations \u2013 Part 1: General requirements\u201d Clause 20.5-7 Figure 13<\/p>\n<p><strong>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f:<\/strong><\/p>\n<table style=\"width: 99.8404%; height: 213px;\" width=\"481\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"211\">Control method<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"270\">Manual<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"211\">Test itinerary<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"270\">250mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"211\">Sheet of hard material<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"270\">1mm\u00b10.1<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"211\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"270\">Cover or cover plates<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"211\">Force gauge parameter<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"270\">0-200N, 0.01N, error &lt;\u00b1 1%, n\/lbf\/kgf three units can be changed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_14548\" class=\"wp-caption aligncenter\" style=\"width: 910px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14548 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/2.jpg\" sizes=\"(max-width: 900px) 100vw, 900px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/2.jpg 900w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/2-400x310.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/2-768x595.jpg 768w\" alt=\"\" width=\"900\" height=\"697\" aria-describedby=\"caption-attachment-14548\" title=\"\"><\/p>\n<p id=\"caption-attachment-14548\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884-1 Clause 24.13-15 Figure 34<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>LS-B14 Test Device for Verification of Cover and Cover plates fully meets requirements of IEC 60884-1:2022 Clause 24.13-15 Figure 34 (GB\/T 2099.1-2021 Clause 24.15-17 and Figure 31), IEC 60669-1:2017 Clause 20.5-7 Figure 13 (GB\/T 16915.1-2024 Clause 20.4-6 and Figure 19). It is used to verify the force required to make the cover or cover plate [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3470,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[557],"class_list":["post-2863","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-b14"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2863","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2863"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2863\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/3470"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2863"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2863"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2863"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}