{"id":2965,"date":"2025-06-19T19:42:51","date_gmt":"2025-06-19T11:42:51","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/spectral-radiance-colorimeter\/"},"modified":"2025-07-01T14:00:45","modified_gmt":"2025-07-01T06:00:45","slug":"spectral-radiance-colorimeter","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ru\/%d0%bf%d1%80%d0%be%d0%b4%d1%83%d0%ba%d1%82%d1%8b\/spectral-radiance-colorimeter\/","title":{"rendered":"\u041a\u043e\u043b\u043e\u0440\u0438\u043c\u0435\u0442\u0440 \u0441\u043f\u0435\u043a\u0442\u0440\u0430\u043b\u044c\u043d\u043e\u0439 \u044f\u0440\u043a\u043e\u0441\u0442\u0438"},"content":{"rendered":"<p><strong>\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0438:<\/strong><\/p>\n<p>\u2022 KS-960 features high dynamic range, high speed, and high precision.<br \/>\n\u2022\u00a0Enables HDR measurement of high-brightness LEDs such as Micro LED and Mini LED without the need for an ND filter.<br \/>\n\u2022\u00a0Supports high-speed and high-precision luminance and chromaticity measurement.<br \/>\n\u2022\u00a0Equipped with a 4.3-inch touchscreen display for touch control of various settings and direct reading of measurement data.<br \/>\n\u2022\u00a0Offers four motorized switchable measurement angles, suitable for both R&amp;D and production line use.<br \/>\n\u2022\u00a0Provides intuitive display of spectral distribution, CIE chromaticity diagram, dominant wavelength, and peak wavelength.<br \/>\n\u2022\u00a0Optional flicker measurement function available.<\/p>\n<div id=\"attachment_16644\" class=\"wp-caption aligncenter\" style=\"width: 1540px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-16644 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u6d4b\u8bd5\u754c\u9762.jpg\" sizes=\"(max-width: 1530px) 100vw, 1530px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u6d4b\u8bd5\u754c\u9762.jpg 1530w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u6d4b\u8bd5\u754c\u9762-400x119.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u6d4b\u8bd5\u754c\u9762-768x228.jpg 768w\" alt=\"\" width=\"1530\" height=\"455\" aria-describedby=\"caption-attachment-16644\" title=\"\"><\/p>\n<p id=\"caption-attachment-16644\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Test interface<\/span><\/p>\n<\/div>\n<p><strong>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438:<\/strong><\/p>\n<table style=\"width: 100.234%; height: 687px;\" width=\"723\">\n<tbody>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\" width=\"333\">\u041c\u043e\u0434\u0435\u043b\u044c LISUN<\/td>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\" width=\"146\">KS-960<\/td>\n<td style=\"width: 33.4578%; text-align: center; vertical-align: middle;\" width=\"244\">KS-960A<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0434\u043b\u0438\u043d \u0432\u043e\u043b\u043d<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">380 \u2013 780nm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Wavelength Accuracy<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">\u00b10.3nm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\" width=\"333\">Spectral Wavelength Width<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">Below 5nm (half-wave width)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Measuring Angles<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">Four electrically switchable measuring angles\uff082\u00b0\u30011\u00b0\u30010.2\u00b0\u30010.1\u00b0 \uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Minimum Brightness Display<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">0.00001cd\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Minimum Spectral Radiance Display<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">10\u207b\u2079W\/(sr\u2022m\u00b2\u2022nm)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Spatial Measurement Function<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">Chromaticity coordinates\u3001color temperature\u3001tristimulus values\u3001dominant wavelength<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Luminance Measuring Range\uff082\u00b0\uff09<\/td>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">0.01 \u2013 20,000cd\/m\u00b2<\/td>\n<td style=\"width: 33.4578%; text-align: center; vertical-align: middle;\">0.001 \u2013 10,000cd\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\" width=\"333\">Luminance Measuring Range\uff081\u00b0\uff09<\/td>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">0.03 \u2013 100,000cd\/m\u00b2<\/td>\n<td style=\"width: 33.4578%; text-align: center; vertical-align: middle;\">0.003 \u2013 100,000cd\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Luminance Measuring Range\uff080.2\u00b0\uff09<\/td>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">0.75 \u2013 500,000cd\/m\u00b2<\/td>\n<td style=\"width: 33.4578%; text-align: center; vertical-align: middle;\">0.075 \u2013 500,000cd\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Luminance Measuring Range\uff080.1\u00b0\uff09<\/td>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">3 \u2013 1,200,000cd\/m\u00b2<\/td>\n<td style=\"width: 33.4578%; text-align: center; vertical-align: middle;\">0.3 \u2013 1,200,000cd\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Chromaticity Accuracy<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">x, y: \u00b10.002@(A light source)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Luminance Repeatability<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"390\">1%@A light source (0.01 \u2013 5cd\/m\u00b2)\uff1b0.5%@A light source (&gt;5cd\/m\u00b2)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Chromaticity Repeatability<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"390\">0.002 @A light source (2\u00b0\uff0c0.01 \u2013 5cd\/m\u00b2)\uff1b0.002 @A light source (2\u00b0\uff0c&gt;5cd\/m\u00b2)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Switch Measurement Angle Mode<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">Electric<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Operating Temperature<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">5 \u2013 50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.8603%; text-align: center; vertical-align: middle;\">Communication<\/td>\n<td style=\"width: 66.3181%; text-align: center; vertical-align: middle;\" colspan=\"2\">USB\/LAN\/WIFI\/RS232 one or multiple<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Typical applications:<\/strong><\/p>\n<p>\u2022\u00a0FPD optical property measurement, analysis and evaluation;<br \/>\n\u2022\u00a0Micro LED, Mini LED optical analysis;<br \/>\n\u2022\u00a0Mobile phone &amp; backlight module brightness and chromaticity analysis;<br \/>\n\u2022\u00a0Illuminated character brightness and chromaticity analysis;<br \/>\n\u2022\u00a0Car dashboard, central control display brightness and chromaticity analysis;<br \/>\n\u2022\u00a0Interior atmosphere lighting analysis;<br \/>\n\u2022\u00a0Brightness analysis of luminous products;<br \/>\n\u2022\u00a0Brightness and chromaticity measurement of various light sources.<\/p>\n<div id=\"attachment_16645\" class=\"wp-caption aligncenter\" style=\"width: 2212px;\">\n<p><img decoding=\"async\" class=\"wp-image-16645 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528.jpg\" sizes=\"(max-width: 2202px) 100vw, 2202px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528.jpg 2202w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528-400x67.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528-1920x323.jpg 1920w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528-768x129.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528-1536x259.jpg 1536w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/03\/\u5178\u578b\u5e94\u7528-2048x345.jpg 2048w\" alt=\"\" width=\"2202\" height=\"371\" aria-describedby=\"caption-attachment-16645\" title=\"\"><\/p>\n<p id=\"caption-attachment-16645\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">\u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Features: \u2022 KS-960 features high dynamic range, high speed, and high precision. \u2022\u00a0Enables HDR measurement of high-brightness LEDs such as Micro LED and Mini LED without the need for an ND filter. \u2022\u00a0Supports high-speed and high-precision luminance and chromaticity measurement. \u2022\u00a0Equipped with a 4.3-inch touchscreen display for touch control of various settings and direct reading [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5146,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[659],"class_list":["post-2965","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ks-960"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/comments?post=2965"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/posts\/2965\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media\/5146"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/media?parent=2965"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/categories?post=2965"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ru\/wp-json\/wp\/v2\/tags?post=2965"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}