{"id":2521,"date":"2025-06-19T19:36:32","date_gmt":"2025-06-19T11:36:32","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/isolation-transformer\/"},"modified":"2025-07-01T16:44:08","modified_gmt":"2025-07-01T08:44:08","slug":"isolation-transformer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/tr\/urunler\/isolation-transformer\/","title":{"rendered":"Transformer with electrical isolation"},"content":{"rendered":"<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">An isolation transformer is a transformer with electrical isolation between the input winding and the output winding.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Isolation transformers are used to prevent accidental contact with live objects. The isolation of the transformer is to isolate the current of the primary and secondary coils. It is widely used in industrial and mining enterprises, the electronics industry, precision instruments and equipment, medical equipment, and machine tool equipment.<\/span><\/span> LISUN'un <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/surge-generator.html\" target=\"_blank\" rel=\"noopener\">Dalgalanma Jenerat\u00f6r\u00fc<\/a> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">series products must be equipped with a matching isolation transformer to work properly.<\/span><\/span><\/span><\/p>\n<p><strong>\u015eartname:<\/strong><br \/>\n\u2022 Input voltage = Output voltage = Customer\u2019s local rated voltage (P<span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">lease inform the specific value of input voltage when placing an order<\/span><\/span><\/span>)<br \/>\n\u2022 Single phase output current = Power * 80%\/Output voltage<br \/>\n\u2022 Three-phase output current = Power * 80%\/1.732\/Output voltage<br \/>\n\u2022 Output Power = A<span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">ctual power used * 1.5<\/span><\/span><\/span><\/p>\n<table style=\"width: 100.421%; height: 448px;\" width=\"561\">\n<tbody>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">\u00d6rnek<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">Input voltage<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">\u00c7\u0131k\u0131\u015f gerilimi<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Input\/Output Power<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITEU-SP4K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">220-240V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">220-240V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Single Phase\/4KVA<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITEU-SP5K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">220-240V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">220-240V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Single Phase\/5KVA<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITEU-SP10K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">220-240V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">220-240V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Single Phase\/10KVA<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITUS-SP2K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">110-120V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">110-120V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Single Phase\/2KVA<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITUS-SP5K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">110-120V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">110-120V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Single Phase\/5KVA<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITEU-TP20K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">316-480V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">316-480V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Three Phases\/20KVA<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 25.4777%; height: 56px;\" width=\"104\">ITUS-TP10K<\/td>\n<td style=\"width: 25.0955%; height: 56px;\" width=\"118\">200-260V<\/td>\n<td style=\"width: 25.3504%; height: 56px;\" width=\"84\">200-260V<\/td>\n<td style=\"width: 22.5478%; height: 56px;\" width=\"83\">Three Phases\/10KVA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>An isolation transformer is a transformer with electrical isolation between the input winding and the output winding. Isolation transformers are used to prevent accidental contact with live objects. The isolation of the transformer is to isolate the current of the primary and secondary coils. It is widely used in industrial and mining enterprises, the electronics [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3383,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[274],"class_list":["post-2521","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-iteu-sp4k"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/posts\/2521","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/comments?post=2521"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/posts\/2521\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/media\/3383"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/media?parent=2521"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/categories?post=2521"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/tags?post=2521"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}