{"id":2534,"date":"2025-06-19T19:36:45","date_gmt":"2025-06-19T11:36:45","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/dc-voltage-dips-and-interruptions-generator\/"},"modified":"2025-07-01T11:54:28","modified_gmt":"2025-07-01T03:54:28","slug":"dc-voltage-dips-and-interruptions-generator","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/tr\/urunler\/dc-voltage-dips-and-interruptions-generator\/","title":{"rendered":"DC Voltage Dips and Interruptions Generator"},"content":{"rendered":"<p>CSS61000-29 DC voltage dips and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at the DC power input port.<\/p>\n<p><strong>Standart:<\/strong><br \/>\nIEC61000-4-29\/EN61000-4-29\/GB\/T17626.29 \u201cElectromagnetic compatibility Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c.input power port immunity tests\u201d<\/p>\n<table style=\"width: 101.121%; height: 221px;\">\n<tbody>\n<tr style=\"height: 15px;\">\n<td style=\"height: 15px; vertical-align: middle; width: 22.1983%; text-align: center;\" width=\"87\">LISUN Modeli<\/td>\n<td style=\"height: 15px; vertical-align: middle; width: 21.5517%; text-align: center;\" width=\"121\">CSS61000-29A<\/td>\n<td style=\"height: 15px; vertical-align: middle; width: 18.4267%; text-align: center;\" width=\"87\">CSS61000-29B<\/td>\n<td style=\"height: 15px; vertical-align: middle; width: 18.4267%; text-align: center;\" width=\"87\">CSS61000-29C<\/td>\n<td style=\"height: 15px; vertical-align: middle; width: 19.718%; text-align: center;\" width=\"87\">CSS61000-29D<\/td>\n<\/tr>\n<tr style=\"height: 55px;\">\n<td style=\"height: 55px; vertical-align: middle; width: 22.1983%; text-align: center;\" width=\"87\">The capacity of the EUT (DC)<\/td>\n<td style=\"height: 55px; vertical-align: middle; width: 21.5517%; text-align: center;\" width=\"121\">Max. 120V\/5A<\/td>\n<td style=\"height: 55px; vertical-align: middle; width: 18.4267%; text-align: center;\" width=\"87\">Max. 120V\/10A<\/td>\n<td style=\"height: 55px; vertical-align: middle; width: 18.4267%; text-align: center;\" width=\"87\">Max. 240V\/5A<\/td>\n<td style=\"height: 55px; vertical-align: middle; width: 19.718%; text-align: center;\" width=\"87\">Max. 240V\/10A<\/td>\n<\/tr>\n<tr style=\"height: 10px;\">\n<td style=\"height: 10px; vertical-align: middle; width: 22.1983%; text-align: center;\" width=\"87\">Dip (interruption) time<\/td>\n<td style=\"height: 10px; vertical-align: middle; width: 78.1231%; text-align: center;\" colspan=\"4\" width=\"382\">1\uff5e60,000mS<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"height: 46px; vertical-align: middle; width: 22.1983%; text-align: center;\" width=\"87\">Dip (interruption) interval time<\/td>\n<td style=\"height: 46px; vertical-align: middle; width: 78.1231%; text-align: center;\" colspan=\"4\" width=\"382\">1\uff5e9,999mS<\/td>\n<\/tr>\n<tr style=\"height: 10px;\">\n<td style=\"height: 10px; vertical-align: middle; width: 22.1983%; text-align: center;\" width=\"87\">The number of dip (interruption)<\/td>\n<td style=\"height: 10px; vertical-align: middle; width: 78.1231%; text-align: center;\" colspan=\"4\" width=\"382\">1\uff5e9,999 times<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Large LCD touch screen is with built-in Windows CE. If required to comply with IEC61000-4-11 or<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/GBT-17626.11-2008-Chinese-Version-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\"> GB\/T17626.11<\/a> Pls. click here for AC <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/voltage-dips-and-interruptions-generator.html\" target=\"_blank\" rel=\"noopener\">Gerilim D\u00fc\u015f\u00fc\u015fleri ve Kesintileri Jenerat\u00f6r\u00fc<\/a>.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>CSS61000-29 DC voltage dips and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at the DC power input port. Standard: IEC61000-4-29\/EN61000-4-29\/GB\/T17626.29 \u201cElectromagnetic compatibility Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c.input power port immunity tests\u201d [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3179,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[287],"class_list":["post-2534","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-css61000-29"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/posts\/2534","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/comments?post=2534"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/posts\/2534\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/media\/3179"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/media?parent=2534"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/categories?post=2534"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/tr\/wp-json\/wp\/v2\/tags?post=2534"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}