+8618917996096

IEC60068-2-11 Salt Spray Testing

Product No: YWX/Q-010

Leave a Message

Your email address will not be published. Required fields are marked *

7+4 =

Specifications

The Salt Spray Test Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. It meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, GB/T1771, ISO9227, ASTM-B117, GB/T2423-18, QBT3826, QBT3827, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, GJB150, DIN50021-75, ISO3768, ISO 9227, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.

Model Work Room Size (mm) Exterior Size (mm) Voltage Power (KW)
YWX/Q-150 600x450x400 1100x750x930 1Phase/220V 2
YWX/Q-250 900x600x500 1500x900x1150 1Phase/220V 2.5
YWX/Q-750 1100x750x500 1700x1050x1150 1Phase/220V 3.5
YWX/Q-010 1200x800x500 1800x1100x1200 1Phase/220V 3.5
YWX/Q-016 1600x900x600 2300x1300x1300 1Phase/220V 5
YWX/Q-020 2000x1000x600 2700x1400x1500 3Phase/380V 7.5

Specifications:
• A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow.
• Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement.
• Working room temperature range:RT+5℃~50℃ (The setting value cannot be lower than the current ambient temperature); Saturated barrel temperature: +40°C~+63°C;
• Brine temperature: preheated by laboratory temperature; Temperature uniformity: ≤ ±2°C; Temperature fluctuation: ≤ ±1°C;
• Test time: 0-99,999 M adjustable; Settlement: 1-2ml/80cm²/h;
• Spray method: NSS (neutral) test, AASS (acidic) test, CASS (copper acceleration) test, custom test, programmable test, each test can choose continuous spray or intermittent spray (according to industry standards). The ratio of each test solution has a corresponding explanation in the test setting interface.
• Sample holder: at an angle of 15 to 30 degrees from the vertical surface (with sample standard placed). Other irregular samples are recommended to remain tilted. The V-groove has a single weighing capacity of 3KG, and the O-bar has a single bearing capacity of 5KG. It is strictly forbidden to place samples under heavy weight.

Download

YWX/Q-750 Calibrate Certificate IEC60068-2-11 1981 Standard Free Download ASTM_B117-2011 Standard Free Download ISO 9227-2012 Chinese Version Standard Free Download GB/T-10125 1997 Standard Free Download GB/T 10125-2012 Standard Free Download GB/T 2423.17-2008 Standard Free Download QBT 3826-1999 Standard Free Download QBT 3827-1999 Standard Free Download

video

IEC60068-2-11 Salt Spray Testing

vedio